Skip to main content
Log in

Jugular bulb desaturation during off-pump coronary artery bypass surgery

  • Original Article
  • Published:
Journal of Anesthesia Aims and scope Submit manuscript

Abstract

Purpose

Off-pump coronary artery bypass grafting surgery (OPCAB) frequently results in significant jugular bulb desaturation. Although jugular bulb desaturation during OPCAB may be associated with postoperative cerebral injury, routine jugular bulb oximetry appears to be invasive and expensive. We hypothesized that intraoperative hemodynamic compromise during OPCAB due to cardiac displacement is associated with jugular bulb desaturation which correlates with specific hemodynamic and physiological changes.

Methods

Hemodynamic and physiological data were measured at the following points: (1) before anastomosis of the coronary artery (baseline); (2) during anastomosis of the left anterior descending artery; (3) during anastomosis of the circumflex branch or posterior descending artery; and (4) after chest closure. Arterial, mixed venous, and jugular venous bulb blood gas analyses were performed serially.

Results

Jugular bulb desaturation (≤50%) frequently occurred during surgical displacement of the heart. Mixed venous oxygen saturation (\( Sv_{O_2 } \)), partial pressure of carbon dioxide (\( Pa_{CO_2 } \)), and central venous pressure (CVP) showed a significant relationship with jugular bulb oxygen saturation (r = 0.45) by multivariate linear regression analysis. Multivariate logistic regression analysis also demonstrated that \( Sv_{O_2 } \) ≤ 70%, \( Pa_{CO_2 } \) ≤ 40 mmHg, and CVP ≥ 8 mmHg were likely predictors of the occurrence of jugular bulb desaturation.

Conclusion

Changes in \( Sv_{O_2 } \) and \( Pa_{CO_2 } \) were associated with jugular bulb oxygen saturation, and \( Sv_{O_2 } \) ≤ 70%, \( Pa_{CO_2 } \) ≤ 40 mmHg, and CVP ≥ 8 mmHg had a significant odds ratio for jugular bulb desaturation. We suggest that achieving normal values of \( Sv_{O_2 } \), \( Pa_{CO_2 } \), and CVP may be important to prevent cerebral desaturation during OPCAB.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Abu-Omar Y, Balacumaraswami L, Pigott DW, Matthews PM, Taggart DP. Solid and gaseous cerebral microembolization during off-pump, on-pump, and open cardiac surgery procedures. J Thorac Cardiovasc Surg. 2004;127:1759–1765.

    Article  PubMed  Google Scholar 

  2. Levy JH, Tanaka KA. Inflammatory response to cardiopulmonary bypass. Ann Thorac Surg. 2003;75:S715–S720.

    Article  PubMed  Google Scholar 

  3. Murphy GJ, Angelini GD. Side effects of cardiopulmonary bypass: what is the reality? J Card Surg. 2004;19:481–488.

    Article  CAS  PubMed  Google Scholar 

  4. Cavalca V, Sisillo E, Veglia F, Tremoli E, Cighetti G, Salvi L, Sola A, Mussoni L, Biglioli P, Folco G, Sala A, Parolari A. Isoprostanes and oxidative stress in off-pump and on-pump coronary bypass surgery. Ann Thorac Surg. 2006;81:562–567.

    Article  PubMed  Google Scholar 

  5. Biancari F, Mosorin M, Rasinaho E, Lahtinen J, Heikkinen J, Niemela E, Anttila V, Lepojarvi M, Juvonen T. Postoperative stroke after off-pump versus on-pump coronary artery bypass surgery. J Thorac Cardiovasc Surg. 2007;133:169–173.

    Article  PubMed  Google Scholar 

  6. Van Dijk D, Jansen EW, Hijman R, Nierich AP, Diephuis JC, Moons KG, Lahpor JR, Borst C, Keizer AM, Nathoe HM, Grobbee DE, De Jaegere PP, Kalkman CJ. Cognitive outcome after off-pump and on-pump coronary artery bypass graft surgery: a randomized trial. JAMA. 2002;287:1405–1412.

    Article  PubMed  Google Scholar 

  7. van Dijk D, Spoor M, Hijman R, Nathoe HM, Borst C, Jansen EW, Grobbee DE, de Jaegere PP, Kalkman CJ. Cognitive and cardiac outcomes 5 years after off-pump vs on-pump coronary artery bypass graft surgery. JAMA. 2007;297:701–708.

    Article  PubMed  Google Scholar 

  8. Diephuis JC, Moons KG, Nierich AN, Bruens M, van Dijk D, Kalkman CJ. Jugular bulb desaturation during coronary artery surgery: a comparison of off-pump and on-pump procedures. Br J Anaesth. 2005;94:715–720.

    Article  CAS  PubMed  Google Scholar 

  9. Kim JY, Kwak YL, Oh YJ, Kim SH, Yoo KJ, Hong YW. Changes in jugular bulb oxygen saturation during off-pump coronary artery bypass graft surgery. Acta Anaesthesiol Scand. 2005;49:956–961.

    Article  CAS  PubMed  Google Scholar 

  10. Croughwell ND, Newman MF, Blumenthal JA, White WD, Lewis JB, Frasco PE, Smith LR, Thyrum EA, Hurwitz BJ, Leone BJ. Jugular bulb saturation and cognitive dysfunction after cardiopulmonary bypass. Ann Thorac Surg. 1994;58:1702–1708.

    CAS  PubMed  Google Scholar 

  11. Yoda M, Nonoyama M, Shimakura T. Cerebral perfusion during off-pump coronary artery bypass grafting. Surg Today. 2004;34:501–505.

    Article  PubMed  Google Scholar 

  12. Gopinath SP, Valadka AB, Uzura M, Robertson CS. Comparison of jugular venous oxygen saturation and brain tissue PO2 as monitors of cerebral ischemia after head injury. Crit Care Med. 1999;27:2337–2345.

    Article  CAS  PubMed  Google Scholar 

  13. Gupta AK, Hutchinson PJ, Al-Rawi P, Gupta S, Swart M, Kirkpatrick PJ, Menon DK, Datta AK. Measuring brain tissue oxygenation compared with jugular venous oxygen saturation for monitoring cerebral oxygenation after traumatic brain injury. Anesth Analg. 1999;88:549–553.

    Article  CAS  PubMed  Google Scholar 

  14. Imberti R, Bellinzona G, Langer M. Cerebral tissue PO2 and SjvO2 changes during moderate hyperventilation in patients with severe traumatic brain injury. J Neurosurg. 2002;96:97–102.

    Article  PubMed  Google Scholar 

  15. Oertel M, Kelly DF, Lee JH, McArthur DL, Glenn TC, Vespa P, Boscardin WJ, Hovda DA, Martin NA. Efficacy of hyperventilation, blood pressure elevation, and metabolic suppression therapy in controlling intracranial pressure after head injury. J Neurosurg. 2002;97:1045–1053.

    Article  PubMed  Google Scholar 

  16. Croughwell ND, Frasco P, Blumenthal JA, Leone BJ, White WD, Reves JG. Warming during cardiopulmonary bypass is associated with jugular bulb desaturation. Ann Thorac Surg. 1992;53:827–832.

    Article  CAS  PubMed  Google Scholar 

  17. Souter MJ, Andrews PJ, Alston RP. Jugular venous desaturation following cardiac surgery. Br J Anaesth. 1998;81:239–241.

    CAS  PubMed  Google Scholar 

  18. Polonen P, Ruokonen E, Hippelainen M, Poyhonen M, Takala J. A prospective, randomized study of goal-oriented hemodynamic therapy in cardiac surgical patients. Anesth Analg. 2000;90:1052–1059.

    Article  CAS  PubMed  Google Scholar 

  19. Rao V, Ivanov J, Weisel RD, Ikonomidis JS, Christakis GT, David TE. Predictors of low cardiac output syndrome after coronary artery bypass. J Thorac Cardiovasc Surg. 1996;112:38–51.

    Article  CAS  PubMed  Google Scholar 

  20. Rao V, Ivanov J, Weisel RD, Cohen G, Borger MA, Mickle DA. Lactate release during reperfusion predicts low cardiac output syndrome after coronary bypass surgery. Ann Thorac Surg. 2001;71:1925–1930.

    Article  CAS  PubMed  Google Scholar 

  21. Maganti MD, Rao V, Borger MA, Ivanov J, David TE. Predictors of low cardiac output syndrome after isolated aortic valve surgery. Circulation. 2005;112:I448–I452.

    PubMed  Google Scholar 

  22. Yeh T Jr, Gouldman J, Auden SM, Seremet V, Edmonds HL Jr, Cerrito PB, Austin EH3rd. Mixed venous oxygen saturation does not adequately predict cerebral perfusion during pediatric cardiopulmonary bypass. J Thorac Cardiovasc Surg. 2001;122:192–193.

    Article  PubMed  Google Scholar 

  23. Grundeman PF, Borst C, van Herwaarden JA, Mansvelt Beck HJ, Jansen EW. Hemodynamic changes during displacement of the beating heart by the Utrecht Octopus method. Ann Thorac Surg. 1997;63:S88–92.

    Article  CAS  PubMed  Google Scholar 

  24. Grundeman PF, Borst C, van Herwaarden JA, Verlaan CW, Jansen EW. Vertical displacement of the beating heart by the octopus tissue stabilizer: influence on coronary flow. Ann Thorac Surg. 1998;65:1348–1352.

    Article  CAS  PubMed  Google Scholar 

  25. Nierich AP, Diephuis J, Jansen EW, Borst C, Knape JT. Heart displacement during off-pump CABG: how well is it tolerated? Ann Thorac Surg. 2000;70:466–472.

    Article  CAS  PubMed  Google Scholar 

  26. Kwak YL, Oh YJ, Jung SM, Yoo KJ, Lee JH, Hong YW. Change in right ventricular function during off-pump coronary artery bypass graft surgery. Eur J Cardiothorac Surg. 2004;25:572–577.

    Article  CAS  PubMed  Google Scholar 

  27. Mathison M, Edgerton JR, Horswell JL, Akin JJ, Mack MJ. Analysis of hemodynamic changes during beating heart surgical procedures. Ann Thorac Surg. 2000;70:1355–1360; discussion 60-1.

    Article  CAS  PubMed  Google Scholar 

  28. Chang WI, Kim KB, Kim JH, Ham BM, Kim YL. Hemodynamic changes during posterior vessel off-pump coronary artery bypass: comparison between deep pericardial sutures and vacuum-assisted apical suction device. Ann Thorac Surg. 2004;78:2057–2062.

    Article  PubMed  Google Scholar 

  29. Petersen KD, Landsfeldt U, Cold GE, Petersen CB, Mau S, Hauerberg J, Holst P, Olsen KS. Intracranial pressure and cerebral hemodynamics in patients with cerebral tumors: a randomized prospective study of patients subjected to craniotomy in propofolfentanyl, isoflurane-fentanyl, or sevoflurane-fentanyl anesthesia. Anesthesiology. 2003;98:329–336.

    Article  CAS  PubMed  Google Scholar 

  30. Ali MS, Harmer M, Vaughan RS, Dunne JA, Latto IP. Spatially resolved spectroscopy (NIRO-300) does not agree with jugular bulb oxygen saturation in patients undergoing warm bypass surgery. Can J Anaesth. 2001;48:497–501.

    Article  CAS  PubMed  Google Scholar 

  31. Yamashita K, Kazui T, Terada H, Washiyama N, Suzuki K, Bashar AH. Cerebral oxygenation monitoring for total arch replacement using selective cerebral perfusion. Ann Thorac Surg. 2001;72:503–508.

    Article  CAS  PubMed  Google Scholar 

  32. Leyvi G, Bello R, Wasnick JD, Plestis K. Assessment of cerebral oxygen balance during deep hypothermic circulatory arrest by continuous jugular bulb venous saturation and near-infrared spectroscopy. J Cardiothorac Vasc Anesth. 2006;20:826–833.

    Article  PubMed  Google Scholar 

  33. Yoshitani K, Kawaguchi M, Miura N, Okuno T, Kanoda T, Ohnishi Y, Kuro M. Effects of hemoglobin concentration, skull thickness, and the area of the cerebrospinal fluid layer on near-infrared spectroscopy measurements. Anesthesiology. 2007;106:458–462.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

About this article

Cite this article

Miura, N., Yoshitani, K., Kawaguchi, M. et al. Jugular bulb desaturation during off-pump coronary artery bypass surgery. J Anesth 23, 477–482 (2009). https://doi.org/10.1007/s00540-009-0794-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00540-009-0794-8

Key words

Navigation