Skip to main content
Log in

Garment size effect of thermal protective clothing on global and local evaporative cooling of walking manikin in a hot environment

  • Original Paper
  • Published:
International Journal of Biometeorology Aims and scope Submit manuscript

Abstract

Evaporative cooling is the critical heat dissipation mechanism for working individuals wearing thermal protective clothing in hot environments. However, until now, there is no knowledge on garment size design for evaporative cooling optimization, especially when the human body is in movements. In this study, to understand the dynamic effect of garment size on evaporative cooling, we performed experiments on a sweating thermal manikin with seven garment sizes and three walking speeds. The evaporative cooling of global and local manikin body with this wide range garment sizes was present. Results demonstrated that the effect of garment size on evaporative cooling depended on the walking speed. At lower walking speeds, the global evaporative cooling tended to decrease with greater garment size, while at higher walking speeds, the global evaporative cooling tended to increase with greater garment size. Similarly, according to effects of garment size on local evaporative cooling, body segments could be divided into three categories for evaporative cooling optimization. Further, we analyzed factors which influenced the positive effect of walking speed on the evaporative cooling. Results showed that, for most cases, the increase of evaporative cooling caused by walking showed positive linear relationship with the garment size. Further increase of walking speed led to a greater increase rate of evaporative heat loss for body segments with the small air gap. This study provides insights into clothing local characteristics of evaporative cooling with different garment sizes under dynamic conditions and may help clothing design to optimize the evaporative cooling of working individuals in hot environments.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  • Anttonen H, Hiltunen E (2009) The effect of wind on thermal insulation of military clothing. In: RTO Human Factors and Medicine Panel Symposium, RTO-MP-HFM-168, Neuilly-sue-Seine. NATO Science and Technology Organization, pp 1-12

    Google Scholar 

  • ASTM F2370–16 (2016) Standard Test Method for Measuring the Evaporative Resistance of Clothing Using a Sweating Manikin. ASTM international, West Conshohocken. https://doi.org/10.1520/f2370-16

  • Chen Y, Fan J, Qian X, Zhang W (2004) Effect of garment fit on thermal insulation and evaporative resistance. Text Res J 74:742–748. https://doi.org/10.1177/004051750407400814

  • Ding D, Tang T, Song G, McDonald A (2011) Characterizing the performance of a single-layer fabric system through a heat and mass transfer model-part II: thermal and evaporative resistances. Text Res J 81:945–958. https://doi.org/10.1177/0040517510395994

  • Frackiewicz-Kaczmarek J, Psikuta A, Bueno MA, Rossi RM (2015a) Air gap thickness and contact area in undershirts with various moisture contents: influence of garment fit, fabric structure and fiber composition. Text Res J 85:2196–2207. https://doi.org/10.1177/0040517514551458

  • Frackiewicz-Kaczmarek J, Psikuta A, Bueno MA, Rossi RM (2015b) Effect of garment properties on air gap thickness and the contact area distribution. Text Res J 85:1907–1918. https://doi.org/10.1177/0040517514559582

  • Havenith G et al (2008) Apparent latent heat of evaporation from clothing: attenuation and “heat pipe” effects. J Appl Physiol 104:142–149. https://doi.org/10.1152/japplphysiol.00612.2007

  • ISO 9920:2007 (2007) Ergonomics of the thermal environment — Estimation of thermal insulation and water vapour resistance of a clothing ensemble. International Organization for Standardization, Geneva

  • Lotens WA, Havenith G (1988) Ventilation of rain wear determined by a tracer gas method. In: Mekjavic IB, Banister EW, Morison JB (eds) Environmental ergonomics, Philadelphia. Taylor and Francis, pp 162–176

  • Lu Y, Wang F, Peng H, Shi W, Song G (2016) Effect of sweating set rate on clothing real evaporative resistance determined on a sweating thermal manikin in a so-called isothermal condition (Tmanikin = Ta = Tr). Int J Biometeorol 60:481–488. https://doi.org/10.1007/s00484-015-1029-3

  • Lu Y, Wang F, Wan X, Song G, Shi W, Zhang C (2015a) Clothing resultant thermal insulation determined on a movable thermal manikin. Part I: effects of wind and body movement on total insulation. Int J Biometeorol 59:1475–1486. https://doi.org/10.1007/s00484-015-0958-1

    Article  Google Scholar 

  • Lu Y, Wang F, Wan X, Song G, Zhang C, Shi W (2015b) Clothing resultant thermal insulation determined on a movable thermal manikin. Part II: effects of wind and body movement on local insulation. Int J Biometeorol 59:1487–1498. https://doi.org/10.1007/s00484-015-0959-0

    Article  Google Scholar 

  • Luo N, Weng W, Fu M, Yang J, Han Z (2014) Experimental study of the effects of human movement on the convective heat transfer coefficient. Exp Therm Fluid Sci 57:40–56. https://doi.org/10.1016/j.expthermflusci.2014.04.001

  • Mert E, Boehnisch S, Psikuta A, Bueno MA, Rossi RM (2016) Contribution of garment fit and style to thermal comfort at the lower body. Int J Biometeorol 60:1995–2004. https://doi.org/10.1007/s00484-016-1258-0

  • Mert E, Psikuta A, Arevalo M, Charbonnier C, Luible-Bar C, Bueno M-A, Rossi RM (2018) A validation methodology and application of 3D garment simulation software to determine the distribution of air layers in garments during walking. Measurement 117:153–164. https://doi.org/10.1016/j.measurement.2017.11.042

    Article  Google Scholar 

  • Mert E, Psikuta A, Bueno MA, Rossi RM (2015) Effect of heterogenous and homogenous air gaps on dry heat loss through the garment. Int J Biometeorol 59:1701–1710. https://doi.org/10.1007/s00484-015-0978-x

  • Mert E, Psikuta A, Bueno MA, Rossi RM (2017) The effect of body postures on the distribution of air gap thickness and contact area. Int J Biometeorol 61:363–375. https://doi.org/10.1007/s00484-016-1217-9

  • Oliveira AV, Gaspar AR, Francisco SC, Quintela DA (2012) Convective heat transfer from a nude body under calm conditions: assessment of the effects of walking with a thermal manikin. Int J Biometeorol 56:319–332. https://doi.org/10.1007/s00484-011-0436-3

  • Psikuta A, Mert E, Annaheim S, Rossi RM (2018) Local air gap thickness and contact area models for realistic simulation of human thermo-physiological response. Int J Biometeorol 62:1121-1134. https://doi.org/10.1007/s00484-018-1515-5

  • Wang F et al (2012) Localised boundary air layer and clothing evaporative resistances for individual body segments. Ergonomics 55:799–812. https://doi.org/10.1080/00140139.2012.668948

  • Wang F, Peng H, Shi W (2016) The relationship between air layers and evaporative resistance of male Chinese ethnic clothing. Appl Ergon 56:194–202. https://doi.org/10.1016/j.apergo.2016.04.005

Download references

Funding

This work was supported by the Fundamental Research Funds for the Central Universities (Grant NO. 2232019G-08); the National Key Research and Development Plan (Grant NO. 2017YFB0309100); and the China Scholarship Council.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jun Li.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Additional information

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Guan, M., Li, J. Garment size effect of thermal protective clothing on global and local evaporative cooling of walking manikin in a hot environment. Int J Biometeorol 64, 485–499 (2020). https://doi.org/10.1007/s00484-019-01836-5

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00484-019-01836-5

Keywords

Navigation