Accuracy of pulse oximetry during intense exercise under severe hypoxic conditions

  • ORIGINAL ARTICLE
  • Published:
European Journal of Applied Physiology and Occupational Physiology Aims and scope Submit manuscript

Abstract

There is a growing need to measure arterial oxygen saturation with a non-invasive method during heavy exercise under severe hypoxic conditions. Although the accuracy of pulse oximetry has been challenged by several authors, it has not been done under extreme conditions. The purpose of this study was to evaluate the accuracy of a pulse oximeter (Satlite, Datex, Finland) during exercise under hypoxic conditions where arterial oxygen saturation was below 75%, simulating exercise at extreme altitude. Ten healthy non-smoking men performed two exercise studies of 30 min under normoxia and under hypoxia on two consecutive days. The exercise intensity was 80% of maximal O2 consumption of O2max. Arterial oxygen saturation measured by pulse oximetry was corrected (S pO2[corr]) according to previously published equations and was compared to arterial oxygen saturation (S aO2) in blood samples taken simultaneously from the radial artery. Reference arterial saturation values ranged from 57.2 to 97.6% for the whole data set. This data set was split according to low (S aO2 ≤ 75%) and high (S aO2 > 75%) S aO2 values. The error of pulse oximetry (S pO2[corr] S aO2) was 2.05 (0.87)% [mean (SD)] and 1.80 (1.81)% for high and low S aO2 values, respectively. S pO2[corr] and S aO2 were highly correlated (r = 0.93, SEE = 1.8) for low values. During high-intensity constant workload under severe hypoxic conditions, once corrected, pulse oximetry provides an estimate of S aO2 with a mean error of 2%. Thus, the correction previously described for S pO2 values above 75% saturation applies also to S pO2 values in the range of 57–75% during exercise under hypoxic conditions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Accepted: 27 February 1997

Rights and permissions

Reprints and permissions

About this article

Cite this article

Benoit, H., Costes, F., Feasson, L. et al. Accuracy of pulse oximetry during intense exercise under severe hypoxic conditions. Eur J Appl Physiol 76, 260–263 (1997). https://doi.org/10.1007/s004210050245

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004210050245

Navigation