Skip to main content

Advertisement

Log in

The Carina© middle ear implant: surgical and functional outcomes

  • Otology
  • Published:
European Archives of Oto-Rhino-Laryngology Aims and scope Submit manuscript

Abstract

The Carina© system (Cochlear Ltd, Sydney, Australia) is a totally implantable prosthesis designed to meet the needs of acoustic amplification in adults with moderate-to-severe sensorineural or mixed hearing loss. It mechanically stimulates the ossicles or labyrinthine windows. The object of this study was to update surgical and functional results obtained in a consistent sample of Carina© recipients. The data sheets of 26 patients who underwent Carina© surgery at two ENT units [i.e., ENT Audiology and Phoniatrics Unit of the University Hospital of Pisa (Pisa, Italy) and ENT Unit of “Guglielmo da Saliceto” Hospital of Piacenza (Piacenza, Italy)] were evaluated for the surgical and audiological outcomes. Twenty patients received a unilateral device, whereas six patients were bilaterally implanted (simultaneously in one patient and sequentially in the remaining five patients). The total number of ears implanted in this study was 32. Most implanted patients expressed a high degree of satisfaction with the prosthesis, which highlights the improvement in hearing in different environmental conditions, the cosmetic advantages, and greater freedom in performing common activities in daily living. Audiological examination demonstrated valid functional gain and significant improvement in speech perception in quiet. Based on this experience, the Carina© is a valid alternative to hearing aids. Moreover, a bilateral implantation, even a simultaneous implantation, is a viable option for selected motivated patients because the intervention is generally well tolerated and the surgery time is relatively fast.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

  1. Barbara M, Manni V, Monini S (2008) Totally implantable middle ear device for rehabilitation of sensorineural hearing loss: preliminary experience with the Esteem®, Envoy. Acta Otolaryngol 31:1–4

    Google Scholar 

  2. Bruschini L, Forli F, Giannarelli M, Bruschini P, Berrettini S (2009) Exclusive transcanal surgical approach for vibrant soundbridge implantation: surgical and functional results. Otol Neurotol 30:950–955

    Article  PubMed  Google Scholar 

  3. Bruschini L, Forli F, Passetti S, Bruschini P, Berrettini S (2010) Fully implantable Otologics MET Carina™ device for the treatment of sensorineural and mixed hearing loss: audio-otological results. Acta Otolaryngol 130:1147–1153

    Article  PubMed  Google Scholar 

  4. Bruschini L, Forli F, Santoro A, Bruschini P, Berrettini S (2009) Fully implantable Otologics MET Carina device for the treatment of sensorineural hearing loss. Preliminary surgical and clinical results. Acta Otorhinolaryngol Ital 29:79–85

    CAS  PubMed  PubMed Central  Google Scholar 

  5. Fisch U, Cremers CW, Lenarz T, Weber B, Babighian G, Uziel AS et al (2001) Clinical experience with the vibrant sound-bridge implant device. Otol Neurotol 22:962–972

    Article  CAS  PubMed  Google Scholar 

  6. Jenkins HA, Niparko JK, Slattery WH, Neely JG, Fredrickson JM (2004) Otologics middle ear transducer ossicular stimulator: performance results with varying degrees of sensorineural hearing loss. Acta Otolaryngol 124:391–394

    Article  PubMed  Google Scholar 

  7. Kasic JF, Fredrickson JM (2001) The Otologics MET ossicular stimulator. Otolaryngol Clin N Am 34:501–513

    Article  CAS  Google Scholar 

  8. Venail F, Lavieille JP, Meller R, Deveze A, Tardivet L, Magnan J (2007) New perspectives for middle ear implants: first results in otosclerosis with mixed hearing loss. Laryngoscope 117:552–555

    Article  PubMed  Google Scholar 

  9. Jenkins HA, Atkins JS, Horlbeck D, Hoffer ME, Balough B, Arigo JV et al (2007) Phase 1 preliminary results of use of the Otologics MET fully implantable ossicular stimulator. Otolaryngol Head Neck Surg 137:206–212

    Article  PubMed  Google Scholar 

  10. Jenkins HA, Pergola N, Kasic J (2007) Intra-operative ossicular loading with the Otologics fully implantable hearing device. Acta Otolaryngol 127:360–364

    Article  PubMed  Google Scholar 

  11. Lefebvre PP, Martin C, Dubreuil C, Decat M, Yazbeck A, Kasic J et al (2009) A pilot study of the safety and performance of the Otologics fully implantable hearing device: transducing sounds via the round window membrane to the inner ear. Audiol Neurootol 14:172–180

    Article  CAS  PubMed  Google Scholar 

  12. Martin C, Deveze A, Richard C, Lefebvre PP, Decat M, Ibañez LG, Truy E, Mom T (2009) European results with totally implantable carina placed on the round window: 2-year follow-up. Otol Neurotol 30(8):1196–1203

    Article  PubMed  Google Scholar 

  13. Siegert R, Mattheis S, Kasic J (2007) Fully implantable hearing aids in patients with congenital auricolar atresia. Laryngoscope 117:336–340

    Article  PubMed  Google Scholar 

  14. Tringali S, Pergola N, Berger P, Dubreuil C (2009) Fully implantable hearing device with transducer on the round window as a treatment of mixed hearing loss. Auris Nasus Larynx 36:353–358

    Article  PubMed  Google Scholar 

  15. Tringali S, Pergola N, Ferber-Viart F, Truy E, Berger P, Dubreuil C (2008) Fully implantable hearing device as a new treatment of conductive hearing loss in Franceschetti syndrome. Int J Pediatr Otorhinolaryngol 72:513–517

    Article  PubMed  Google Scholar 

  16. Debeaupte M, Decullier E, Tringali S, Deveze A, Mom T, Darrouzet V, Truy E (2015) Evolution of the reliability PF the fully implantable middle ear transducer over successive generations. Otol Neurotol 36:625–630

    Article  PubMed  Google Scholar 

  17. Turrini M, Cutugno F, Maturi P, Prosser S, Leoni FA, Arslan E (1993) Bisyllabic words for speech audiometry: a new Italian material. Acta Otorhinolaryngol Ital 13:63–77

    CAS  PubMed  Google Scholar 

  18. Anonymous (1995) Committee on hearing and equilibrium guidelines for the evaluation of results of treatment of conductive hearing loss. American Academy of Otolaryngology-Head and Neck Surgery Foundation, Inc. Otolaryngol Head Neck Surg 113:186–187

    Article  Google Scholar 

  19. Cox RM, Alexander GC, Gray GA (2003) Audiometric correlates of the unaided APHAB. J Am Acad Audiol 14:361–371

    PubMed  Google Scholar 

  20. Kontorinis G, Lenarz T, Schwab B (2010) Anatomic limitations in implantation of middle ear transducer and carina middle ear implants. Laryngoscope 120(11):2289–2293

    Article  PubMed  Google Scholar 

  21. Klein K, Nardelli A, Stafinski T (2012) A systematic review of the safety and effectiveness of fully implantable middle ear hearing devices: the Carina and Esteem systems. Otol Neurotol 33(6):916–921

    PubMed  Google Scholar 

  22. Lachowska M, Niemczyk K, Yazbeck A, Morawski K, Bruzgielewicz A (2012) First bilateral simultaneous implantation with fully implantable middle ear. Hearing device. Arch Med Sci 8:736–742

    Article  PubMed  PubMed Central  Google Scholar 

  23. Zenner HP, Rodriguez JJ (2010) Totally implantable active middle ear implants. Ten years’ experience at the University of Tübingen. Adv Otorhinolaryngol 69:72–84

    CAS  PubMed  Google Scholar 

  24. Deveze A, Rameh C, Sanjuan M, Lavieille JP, Magnan J (2010) A middle ear implant with a titanium canal wall prosthesis for a case of an open mastoid cavity. Auris Nasus Larynx 37:631–635

    Article  PubMed  Google Scholar 

  25. Kam AC, Sung JK, Yu JK, Tong MC (2012) Clinical evaluation of a fully implantable hearing device in six patients with mixed and sensorineural hearing loss: our experience. Clin Otolaryngol 37:240–244

    Article  CAS  PubMed  Google Scholar 

  26. Otologics (2011) Fully implantable ossicular stimulator MET D109629 Rev B. In: Surgical training manual European Union. Otologics LLC, Boulder

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Luca Bruschini.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical standard

All procedures performed in studies involving human participants were in accordance with the ethical standards of our institutional research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.

Informed consent

Informed consent was obtained from all individual participants included in the study.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Bruschini, L., Berrettini, S., Forli, F. et al. The Carina© middle ear implant: surgical and functional outcomes. Eur Arch Otorhinolaryngol 273, 3631–3640 (2016). https://doi.org/10.1007/s00405-016-3998-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00405-016-3998-1

Keywords

Navigation