Abstract
The Carina© system (Cochlear Ltd, Sydney, Australia) is a totally implantable prosthesis designed to meet the needs of acoustic amplification in adults with moderate-to-severe sensorineural or mixed hearing loss. It mechanically stimulates the ossicles or labyrinthine windows. The object of this study was to update surgical and functional results obtained in a consistent sample of Carina© recipients. The data sheets of 26 patients who underwent Carina© surgery at two ENT units [i.e., ENT Audiology and Phoniatrics Unit of the University Hospital of Pisa (Pisa, Italy) and ENT Unit of “Guglielmo da Saliceto” Hospital of Piacenza (Piacenza, Italy)] were evaluated for the surgical and audiological outcomes. Twenty patients received a unilateral device, whereas six patients were bilaterally implanted (simultaneously in one patient and sequentially in the remaining five patients). The total number of ears implanted in this study was 32. Most implanted patients expressed a high degree of satisfaction with the prosthesis, which highlights the improvement in hearing in different environmental conditions, the cosmetic advantages, and greater freedom in performing common activities in daily living. Audiological examination demonstrated valid functional gain and significant improvement in speech perception in quiet. Based on this experience, the Carina© is a valid alternative to hearing aids. Moreover, a bilateral implantation, even a simultaneous implantation, is a viable option for selected motivated patients because the intervention is generally well tolerated and the surgery time is relatively fast.
Similar content being viewed by others
References
Barbara M, Manni V, Monini S (2008) Totally implantable middle ear device for rehabilitation of sensorineural hearing loss: preliminary experience with the Esteem®, Envoy. Acta Otolaryngol 31:1–4
Bruschini L, Forli F, Giannarelli M, Bruschini P, Berrettini S (2009) Exclusive transcanal surgical approach for vibrant soundbridge implantation: surgical and functional results. Otol Neurotol 30:950–955
Bruschini L, Forli F, Passetti S, Bruschini P, Berrettini S (2010) Fully implantable Otologics MET Carina™ device for the treatment of sensorineural and mixed hearing loss: audio-otological results. Acta Otolaryngol 130:1147–1153
Bruschini L, Forli F, Santoro A, Bruschini P, Berrettini S (2009) Fully implantable Otologics MET Carina device for the treatment of sensorineural hearing loss. Preliminary surgical and clinical results. Acta Otorhinolaryngol Ital 29:79–85
Fisch U, Cremers CW, Lenarz T, Weber B, Babighian G, Uziel AS et al (2001) Clinical experience with the vibrant sound-bridge implant device. Otol Neurotol 22:962–972
Jenkins HA, Niparko JK, Slattery WH, Neely JG, Fredrickson JM (2004) Otologics middle ear transducer ossicular stimulator: performance results with varying degrees of sensorineural hearing loss. Acta Otolaryngol 124:391–394
Kasic JF, Fredrickson JM (2001) The Otologics MET ossicular stimulator. Otolaryngol Clin N Am 34:501–513
Venail F, Lavieille JP, Meller R, Deveze A, Tardivet L, Magnan J (2007) New perspectives for middle ear implants: first results in otosclerosis with mixed hearing loss. Laryngoscope 117:552–555
Jenkins HA, Atkins JS, Horlbeck D, Hoffer ME, Balough B, Arigo JV et al (2007) Phase 1 preliminary results of use of the Otologics MET fully implantable ossicular stimulator. Otolaryngol Head Neck Surg 137:206–212
Jenkins HA, Pergola N, Kasic J (2007) Intra-operative ossicular loading with the Otologics fully implantable hearing device. Acta Otolaryngol 127:360–364
Lefebvre PP, Martin C, Dubreuil C, Decat M, Yazbeck A, Kasic J et al (2009) A pilot study of the safety and performance of the Otologics fully implantable hearing device: transducing sounds via the round window membrane to the inner ear. Audiol Neurootol 14:172–180
Martin C, Deveze A, Richard C, Lefebvre PP, Decat M, Ibañez LG, Truy E, Mom T (2009) European results with totally implantable carina placed on the round window: 2-year follow-up. Otol Neurotol 30(8):1196–1203
Siegert R, Mattheis S, Kasic J (2007) Fully implantable hearing aids in patients with congenital auricolar atresia. Laryngoscope 117:336–340
Tringali S, Pergola N, Berger P, Dubreuil C (2009) Fully implantable hearing device with transducer on the round window as a treatment of mixed hearing loss. Auris Nasus Larynx 36:353–358
Tringali S, Pergola N, Ferber-Viart F, Truy E, Berger P, Dubreuil C (2008) Fully implantable hearing device as a new treatment of conductive hearing loss in Franceschetti syndrome. Int J Pediatr Otorhinolaryngol 72:513–517
Debeaupte M, Decullier E, Tringali S, Deveze A, Mom T, Darrouzet V, Truy E (2015) Evolution of the reliability PF the fully implantable middle ear transducer over successive generations. Otol Neurotol 36:625–630
Turrini M, Cutugno F, Maturi P, Prosser S, Leoni FA, Arslan E (1993) Bisyllabic words for speech audiometry: a new Italian material. Acta Otorhinolaryngol Ital 13:63–77
Anonymous (1995) Committee on hearing and equilibrium guidelines for the evaluation of results of treatment of conductive hearing loss. American Academy of Otolaryngology-Head and Neck Surgery Foundation, Inc. Otolaryngol Head Neck Surg 113:186–187
Cox RM, Alexander GC, Gray GA (2003) Audiometric correlates of the unaided APHAB. J Am Acad Audiol 14:361–371
Kontorinis G, Lenarz T, Schwab B (2010) Anatomic limitations in implantation of middle ear transducer and carina middle ear implants. Laryngoscope 120(11):2289–2293
Klein K, Nardelli A, Stafinski T (2012) A systematic review of the safety and effectiveness of fully implantable middle ear hearing devices: the Carina and Esteem systems. Otol Neurotol 33(6):916–921
Lachowska M, Niemczyk K, Yazbeck A, Morawski K, Bruzgielewicz A (2012) First bilateral simultaneous implantation with fully implantable middle ear. Hearing device. Arch Med Sci 8:736–742
Zenner HP, Rodriguez JJ (2010) Totally implantable active middle ear implants. Ten years’ experience at the University of Tübingen. Adv Otorhinolaryngol 69:72–84
Deveze A, Rameh C, Sanjuan M, Lavieille JP, Magnan J (2010) A middle ear implant with a titanium canal wall prosthesis for a case of an open mastoid cavity. Auris Nasus Larynx 37:631–635
Kam AC, Sung JK, Yu JK, Tong MC (2012) Clinical evaluation of a fully implantable hearing device in six patients with mixed and sensorineural hearing loss: our experience. Clin Otolaryngol 37:240–244
Otologics (2011) Fully implantable ossicular stimulator MET D109629 Rev B. In: Surgical training manual European Union. Otologics LLC, Boulder
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical standard
All procedures performed in studies involving human participants were in accordance with the ethical standards of our institutional research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Rights and permissions
About this article
Cite this article
Bruschini, L., Berrettini, S., Forli, F. et al. The Carina© middle ear implant: surgical and functional outcomes. Eur Arch Otorhinolaryngol 273, 3631–3640 (2016). https://doi.org/10.1007/s00405-016-3998-1
Received:
Accepted:
Published:
Issue Date: