Abstract
Introduction
Rotational malalignment following closed intramedullary nailing of tibial fractures does not attract attention but is a complication which may lead to serious results. This study aimed to present findings related to rotational malalignment from rotational alignment measurements made clinically and with computerised tomography (CT) in patients who had undergone locked intramedullary nailing for tibial fracture.
Materials and methods
A total of 26 patients (male/female: 23/3) were evaluated after application of reamed locking intramedullary nailing to a diagnosed tibial shaft fracture. The mean age was determined as 37.5 ± 15.6 years. Rotational alignment was measured in both lower extremities clinically as thigh-foot angle (TFA) and radiologically with CT. Rotational malalignment was accepted as a more than 10º difference between the two lower extremities.
Results
Malrotation was determined at more than 10º from TFA in two (7 %) of 26 patients and from CT in five (19 %) of 26 patients. In three of them, the malrotation was >15º. Of the patients determined with malrotation with CT, it was determined from clinical measurements in 40 %. The mean rotational difference was determined as greater with CT measurement (4.7° ± 9.5) compared to the TFA (1.1° ± 5.6) (p < 0.001). No statistically significant relationship was determined between a rotational difference over 10º and the AO fracture type, fracture location and fibula fixation.
Conclusions
A significant number of patients treated with intramedullary nailing for a tibial fracture may result in rotational malalignment. To determine rotational malalignment, a thorough clinical evaluation must be made and different kinds of clinical measurements taken and, when suspicions remain, determination should be made by CT.
Similar content being viewed by others
References
Rosen H, Sandick H (1955) The measurement of tibiofibular torsion. J Bone Joint Surg Am 37-A(4):847–855
Puloski S, Romano C, Buckley R, Powell J (2004) Rotational malalignment of the tibia following reamed intramedullary nail fixation. J Orthop Trauma 18(7):397–402
Turner MS, Smillie IS (1981) The effect of tibial torsion of the pathology of the knee. J Bone Joint Surg Br 63-B(3):396–398
Turner MS (1994) The association between tibial torsion and knee joint pathology. Clin Orthop Relat Res 302:47–51
van der Schoot DK, Den Outer AJ, Bode PJ, Obermann WR, van Vugt AB (1996) Degenerative changes at the knee and ankle related to malunion of tibial fractures. 15-year follow-up of 88 patients. J Bone Joint Surg Br 78(5):722–725
Svoboda SJ, McHale K, Belkoff SM, Cohen KS, Klemme WR (2002) The effects of tibial malrotation on the biomechanics of the tibiotalar joint. Foot Ankle Int 23(2):102–106
Kenawey M, Liodakis E, Krettek C, Ostermeier S, Horn T, Hankemeier S (2011) Effect of the lower limb rotational alignment on tibiofemoral contact pressure. Knee Surg Sports Traumatol Arthrosc 19(11):1851–1859
Staheli LT, Corbett M, Wyss C, King H (1985) Lower-extremity rotational problems in children. Normal values to guide management. J Bone Joint Surg Am 67(1):39–47
Stuberg W, Temme J, Kaplan P, Clarke A, Fuchs R (1991) Measurement of tibial torsion and thigh-foot angle using goniometry and computed tomography. Clin Orthop Relat Res 272:208–212
Jakob RP, Haertel M, Stussi E (1980) Tibial torsion calculated by computerised tomography and compared to other methods of measurement. J Bone Joint Surg Br 62B:238–242
Jend H, Heller M, Dallek M, Schoettle H (1981) Measurement of tibial torsion by computer tomography. Acta Radiol 22:271–275
Laasonen EM, Jokio P, Lindholm TS (1984) Tibial torsion measured by computed tomography. Acta Radiol 25:325–329
Reikerås O, Høiseth A (1989) Torsion of the leg determined by computed tomography. Acta Orthop Scand 60(3):330–333
Sayli U, Bölükbasi S, Atik OS, Gündogdu S (1994) Determination of tibial torsion by computed tomography. J Foot Ankle Surg 33(2):144–147
Prasad CV, Khalid M, McCarthy P, O’Sullivan ME (1999) CT assessment of torsion following locked intramedullary nailing of tibial fractures. Injury 30(7):467–470
Kahn KM, Beals RK (2002) Malrotation after locked intramedullary tibial nailing: three case reports and review of the literature. J Trauma 53(3):549–552
Jaarsma RL, Pakvis DF, Verdonschot N, Biert J, van Kampen A (2004) Rotational malalignment after intramedullary nailing of femoral fractures. J Orthop Trauma 18(7):403–409
Milner CE, Soames RW (1998) A comparison of four in vivo methods of measuring tibial torsion. J Anat 193:139–144
Güven M, Akman B, Unay K, Ozturan EK, Cakici H, Eren A (2009) A new radiographic measurement method for evaluation of tibial torsion: a pilot study in adults. Clin Orthop Relat Res 467(7):1807–1812
Joseph B, Carver RA, Bell MJ, Sharrard WJ, Levick RK, Aithal V, Chacko V, Murthy SV (1987) Measurement of tibial torsion by ultrasound. J Pediatr Orthop 7(3):317–323
Clementz BG (1988) Tibial torsion measured in normal adults. Acta Orthop Scand 59(4):441–442
Clementz BG, Magnusson A (1989) Fluoroscopic measurement of tibial torsion in adults. A comparison of three methods. Arch Orthop Trauma Surg 108:150–153
van der Werken C, Marti RK (1983) Post-traumatic rotational deformity of the lower leg. Injury 15(1):38–40
Jafarinejad AE, Bakhshi H, Haghnegahdar M, Ghomeishi N (2012) Malrotation following reamed intramedullary nailing of closed tibial fractures. Indian J Orthop 46(3):312–316
Court-Brown CM, Christie J, McQueen MM (1990) Closed intramedullary tibial nailing: its use in closed and open type I fractures. J Bone Joint Surg Br 72:605–611
Puno RM, Vaughan JJ, Stetten ML, Johnson JR (1991) Long-term effects of tibial angular malunion on the knee and ankle joints. J Orthop Trauma 5:247–254
Williams J, Gibbons M, Trundle H, Murray D, Worlock P (1995) Complications of nailing in closed tibial fractures. J Orthop Trauma 9:476–481
Freedman EL, Johnson EE (1995) Radiographic analysis of tibial fracture malalignment following intramedullary nailing. Clin Orthop 315:25–33
Court-Brown CM (2006) Fractures of the tibia and fibula. In: Rockwood and Green’s fractures in adults, 6th edn. Lippincott Williams & Wilkins, Philadelphia, p 2129
Theriault B, Turgeon AF, Pelet S (2012) Functional impact of tibial malrotation following intramedullary nailing of tibial shaft fractures. J Bone Joint Surg Am 94:2033–2039
Bonnevialle P, Andrieu S, Bellumore Y, Challé JJ, Rongières M, Mansat M (1998) Torsional abnormalities and length discrepancies after intramedullary nailing for femoral and tibial diaphyseal fracture. Computerized tomography evaluation of 189 fractures. Rev Chir Orthop Reparatrice Appar Mot 84(5):397–410
Kim HD, Lee DS, Eom MJ, Hwang JS, Han NM, Jo GY (2011) Relationship between physical examinations and two-dimensional computed tomographic findings in children with intoeing gait. Ann Rehabil Med 35(4):491–498
Conflict of interest
None.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Say, F., Bülbül, M. Findings related to rotational malalignment in tibial fractures treated with reamed intramedullary nailing. Arch Orthop Trauma Surg 134, 1381–1386 (2014). https://doi.org/10.1007/s00402-014-2052-2
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00402-014-2052-2