Skip to main content

Advertisement

Log in

Clinical applications of functional MRI at 1.0 T: motor and language studies in healthy subjects and patients

  • Neuroradiology
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract.

In this article we describe clinical applications of functional MRI (fMRI) at 1.0 T. All experiments were performed on a commercially available 1.0-T system (Magnetom Impact Expert, Siemens AG, Erlangen, Germany) using a blood oxygen level-dependent (BOLD)-sensitive multi-slice EPI technique (TE 66 ms, 4 mm slice thickness, 210 mm field of view, 64 × 64 acquisition matrix). Different paradigms for localization of the motor cortex and for language lateralization were tested in healthy subjects and patients. Methodological considerations concerning the development of the paradigms are also described. In all healthy subjects, motor activation elicited BOLD signal changes in the sensorimotor cortex, permitting identification of primary motor and sensory cortical areas. Furthermore, focal activation of different cortical areas by a language task was possible in 6 of 10 subjects. Nineteen motor studies were performed in 18 patients with supratentorial lesions, in most cases prior to neurosurgical procedures. In 14 studies, fMRI results demonstrated the localization of the motor hand areas relative to the lesion. The results proved valuable for preoperative planning and contributed to therapeutical decisions. We conclude that functional MRI for clinically relevant applications, such as localization of motor and language function, is feasible even at a field strength of 1.0 T without dedicated equipment.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 5 May 1998; Revision received: 1 July 1998; Accepted: 13 July 1998

Rights and permissions

Reprints and permissions

About this article

Cite this article

Papke, K., Hellmann, T., Renger, B. et al. Clinical applications of functional MRI at 1.0 T: motor and language studies in healthy subjects and patients. Eur Radiol 9, 211–220 (1999). https://doi.org/10.1007/s003300050658

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s003300050658

Navigation