Abstract
Background
Measurement of volumetric change after aesthetic and reconstructive breast surgery is of great significance to plastic surgeons. This study aimed to investigate the influence of respiration on measurement of breast volumetric change via a three-dimensional (3D) scanning technique.
Methods
In this study, ten augmentation mammaplasty patients received preoperative 3D scanning in different respiration states at three time points: the end of normal exhalation (ENE1), the end of normal inhalation (ENI), and the end of normal exhalation again (ENE2). Using Geomagic Studio 12 software, breast volumetric change error (BVCE) was measured between the ENE1 scan and the ENI scan (R1) and between the ENE1 scan and ENE2 scan (R2). Three-dimensional deviation, defined as the shortest distance from one scan to any point on the other scan, was measured in R1 and R2. A paired-sample t test was used to compare the means of BVCE and the 3D deviation between R1 and R2. Pearson’s correlation coefficient was calculated between 3D deviation and BVCE. For the analysis, SPSS program version 16 was used. Differences were considered statistically significant at P values lower than 0.05.
Results
The mean breast volume was 352.3 ± 52.7 ml, and BVCE was significantly lower in R1 than in R2 (9.7 vs. 21.3 ml; P = 0.000). The 3D deviation was significantly higher in R2 than in R1 (1.600 vs. 0.887; P = 0.000). In the analysis, BVCE was not correlated significantly with 3D deviation in R1 (P = 0.157) but was significantly correlated with 3D deviation in R2 (correlation coefficient = 0.766; P = 0.000).
Conclusions
Keeping patients in the same respiration state is crucial for accurate measurement of breast volumetric change via the 3D scanning technique.
Level of Evidence I
This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.
Similar content being viewed by others
References
Rohrich RJ, Hartley W, Brown S: Incidence of breast and chest wall asymmetry in breast augmentation: a retrospective analysis of 100 patients. Plast Reconstr Surg 118:7S–13S; discussion 14S, 15S–17S, 2006
Smith DJ Jr, Palin WE Jr, Katch VL, Bennett JE (1986) Breast volume and anthropomorphic measurements: Normal values. Plast Reconstr Surg 78:331–335
Westreich M (1997) Anthropomorphic breast measurement: Protocol and results in 50 women with aesthetically perfect breasts and clinical application. Plast Reconstr Surg 100:468–479
Loughry CW, Sheffer DB, Price TE Jr, Lackney MJ, Bartfai RG, Morek WM (1987) Breast volume measurement of 248 women using biostereometric analysis. Plast Reconstr Surg 80:553–558
Herson MR, Wexler MR (1988) Volume calculation for breast augmentation and reconstruction with a soft-tissue expander. Plast Reconstr Surg 81:992–993
Loughry CW, Sheffer DB, Price TE, Einsporn RL, Bartfai RG, Morek WM, Meli NM (1989) Breast volume measurement of 598 women using biostereometric analysis. Ann Plast Surg 22:380–385
Edsander-Nord A, Wickman M, Jurell G (1996) Measurement of breast volume with thermoplastic casts. Scand J Plast Reconstr Surg Hand Surg 30:129–132
Esme DL, Bucksch A, Beekman WH (2009) Three-dimensional laser imaging as a valuable tool for specifying changes in breast shape after augmentation mammaplasty. Aesthetic Plast Surg 33:191–195
Tepper OM, Small K, Rudolph L, Choi M, Karp N (2006) Virtual 3-dimensional modeling as a valuable adjunct to aesthetic and reconstructive breast surgery. Am J Surg 192:548–551
Isogai N, Sai K, Kamiishi H, Watatani M, Inui H, Shiozaki H (2006) Quantitative analysis of the reconstructed breast using a 3-dimensional laser light scanner. Ann Plast Surg 56:237–242
Losken A, Fishman I, Denson DD, Moyer HR, Carlson GW (2005) An objective evaluation of breast symmetry and shape differences using 3-dimensional images. Ann Plast Surg 55:571–575
Tepper OM, Karp NS, Small K, Unger J, Rudolph L, Pritchard A, Choi M (2008) Three-dimensional imaging provides valuable clinical data to aid in unilateral tissue expander-implant breast reconstruction. Breast J 14:543–550
Moyer HR, Carlson GW, Styblo TM, Losken A (2008) Three-dimensional digital evaluation of breast symmetry after breast conservation therapy. J Am Coll Surg 207:227–232
Galdino GM, Nahabedian M, Chiaramonte M, Geng JZ, Klatsky S, Manson P (2002) Clinical applications of three-dimensional photography in breast surgery. Plast Reconstr Surg 110:58–70
Nahabedian MY, Galdino G (2003) Symmetrical breast reconstruction: Is there a role for three-dimensional digital photography? Plast Reconstr Surg 112:1582–1590
Tepper OM, Choi M, Small K, Unger J, Davidson E, Rudolph L, Pritchard A, Karp NS (2008) An innovative three-dimensional approach to defining the anatomical changes occurring after short scar-medial pedicle reduction mammaplasty. Plast Reconstr Surg 121:1875–1885
Liu C, Luan J, Mu L, Ji K (2010) The role of three-dimensional scanning technique in evaluation of breast asymmetry in breast augmentation: a 100-case study. Plast Reconstr Surg 126:2125–2132
Kovacs L, Eder M, Hollweck R, Zimmermann A, Settles M, Schneider A, Udosic K, Schwenzer-Zimmerer K, Papadopulos NA, Biemer E (2006) New aspects of breast volume measurement using 3-dimensional surface imaging. Ann Plast Surg 57:602–610
Losken A, Seify H, Denson DD, Paredes AA Jr, Carlson GW (2005) Validating three-dimensional imaging of the breast. Ann Plast Surg 54:471–476 (discussion 77–78)
Kovacs L, Eder M, Hollweck R, Zimmermann A, Settles M, Schneider A, Endlich M, Mueller A, Schwenzer-Zimmerer K, Papadopulos NA, Biemer E (2007) Comparison between breast volume measurement using 3D surface imaging and classical techniques. Breast 16:137–145
Tepper OM, Small KH, Unger JG, Feldman DL, Kumar N, Choi M, Karp NS (2009) 3d Analysis of breast augmentation defines operative changes and their relationship to implant dimensions. Ann Plast Surg 62:570–575
Eder M, Waldenfels Fv, Sichtermann M, Schuster T, Papadopulos NA, Machens HG, Biemer E, Kovacs L (2011) Three-dimensional evaluation of breast contour and volume changes following subpectoral augmentation mammaplasty over 6 months. J Plast Reconstr Aesthet Surg 64:1152–1160
Henseler H, Khambay BS, Bowman A, Smith J, Paul Siebert J, Oehler S, Ju X, Ayoub A, Ray AK (2011) Investigation into accuracy and reproducibility of a 3d breast imaging system using multiple stereo cameras. J Plast Reconstr Aesthet Surg 64:577–582
Liu C, Luan J, Ji K, Sun J (2012) Measuring volumetric change after augmentation mammaplasty using a three-dimensional scanning technique: An innovative method. Aesthet Plast Surg 36:1134–1139
Choi M, Small K, Levovitz C, Lee C, Fadl A, Karp NS (2013) The volumetric analysis of fat graft survival in breast reconstruction. Plast Reconstr Surg 131:185–191
ELFadl D, Garimella V, Mahapatra TK, McManus PL, Drew PJ (2010) Lipomodelling of the breast: a review. Breast 19:202–209
Acknowledgment
This study was supported by Beijing Municipal Science and Technology Commission no. Z131107002213104.
Conflict of interest
The author declares that he has no conflict of interest to disclose.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Liu, C., Ji, K., Sun, J. et al. Does Respiration Influence Breast Volumetric Change Measurement with the Three-Dimensional Scanning Technique?. Aesth Plast Surg 38, 115–119 (2014). https://doi.org/10.1007/s00266-013-0247-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00266-013-0247-5