Skip to main content
Log in

Trunnionosis: the latest culprit in adverse reactions to metal debris following hip arthroplasty

  • Case Report
  • Published:
Skeletal Radiology Aims and scope Submit manuscript

Abstract

The imaging findings of periprosthetic soft tissue lesions (pseudotumours) have been typically defined in the context of newer second-generation metal-on-metal hip arthroplasty. More recently, similar findings have been described in the setting of non-metal-on-metal prostheses. Although uncommon, wear and corrosion between the metal surfaces at the head-neck (‘trunnionosis’) and neck-stem interfaces are the potential culprits. With modular junctions containing at least one cobalt chromium component frequently present in hip arthroplasty prostheses, the incidence of this mode of adverse wear may be higher than previously thought (irrespective of the specific bearing couple used). In the present report, we described a case of a severe adverse local tissue reaction secondary to suspected corrosion at the head-neck taper in a metal-on-polyethylene total hip arthroplasty and reviewed the literature. Knowledge of this topical entity should help radiologists facilitate early diagnosis and ensure early management of this potentially serious complication.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

References

  1. Krieg AH, Speth BM, Ochsner PE. Backside volumetric change in the polyethylene of uncemented acetabular components. J Bone Joint Surg (Br). 2009;91(8):1037–43.

    Article  CAS  Google Scholar 

  2. Cooper HJ, Della Valle CJ, Berger RA, Tetreault M, Paprosky WG, Sporer SM, et al. Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am. 2012;94(18):1655–61.

    PubMed  Google Scholar 

  3. Cooper HJ, Urban RM, Wixson RL, Meneghini RM, Jacobs JJ. Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J Bone Joint Surg Am. 2013;95(10):865–72.

    Article  PubMed Central  PubMed  Google Scholar 

  4. Gill IP, Webb J, Sloan K, Beaver RJ. Corrosion at the neck-stem junction as a cause of metal ion release and pseudotumour formation. J Bone Joint Surg (Br). 2012;94(7):895–900.

    Article  CAS  Google Scholar 

  5. Kop AM, Keogh C, Swarts E. Proximal component modularity in THA—at what cost? An implant retrieval study. Clin Orthop Relat Res. 2012;470(7):1885–94.

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  6. Grammatopolous G, Pandit H, Kwon YM, Gundle R, McLardy-Smith P, Beard DJ, et al. Hip resurfacings revised for inflammatory pseudotumour have a poor outcome. J Bone Joint Surg (Br). 2009;91(8):1019–24.

    Article  CAS  Google Scholar 

  7. Cooper HJ, Della Valle CJ, Jacobs JJ. Biologic implications of taper corrosion in total hip arthroplasty. Semin Arthroplast. 2012;23(4):273–8.

    Article  Google Scholar 

  8. Hallab NJ. Hypersensitivity to implant debris. In: Eliaz N, editor. Degradation of implant materials. New York, NY: Springer; 2012.

    Google Scholar 

  9. Langton DJ, Joyce TJ, Jameson SS, Lord J, Van Orsouw M, Holland JP, et al. Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear. J Bone Joint Surg (Br). 2011;93(2):164–71.

    Article  CAS  Google Scholar 

  10. Schmalzried TP. Metal-metal bearing surfaces in hip arthroplasty. Orthopedics. 2009; 32(9).

  11. Wassef AJ, Schmalzried TP. Femoral taperosis: an accident waiting to happen? Bone Joint J. 2013; 95-B(11 Suppl A):3–6.

  12. Mao X, Wong AA, Crawford RW. Cobalt toxicity–an emerging clinical problem in patients with metal-on-metal hip prostheses? Med J Aust. 2011;194(12):649–51.

    PubMed  Google Scholar 

  13. Tower SS. Arthroprosthetic cobaltism associated with metal on metal hip implants. BMJ. 2012;344:e430.

    Article  PubMed  Google Scholar 

  14. Zywiel MG, Brandt JM, Overgaard CB, Cheung AC, Turgeon TR, Syed KA. Fatal cardiomyopathy after revision total hip replacement for fracture of a ceramic liner. Bone Joint J. 2013; 95-B(1).

  15. Goldberg JR, Gilbert JL, Jacobs JJ, Bauer TW, Paprosky W, Leurgans S. A multicenter retrieval study of the taper interfaces of modular hip prostheses. Clin Orthop Relat Res. 2002;401:149–61.

    Article  PubMed  Google Scholar 

  16. Chana R, Esposito C, Campbell PA, Walter WK, Walter WL. Mixing and matching causing taper wear: corrosion associated with pseudotumour formation. J Bone Joint Surg (Br). 2012;94(2):281–6.

    Article  CAS  Google Scholar 

  17. Bisseling P, Tan T, Lu Z, Campbell PA, Susante JL. The absence of a metal-on-metal bearing does not preclude the formation of a destructive pseudotumor in the hip—a case report. Acta Orthop. 2013;84(4):437–41.

    Article  PubMed Central  PubMed  Google Scholar 

  18. Koper MC, Mathijssen NMC, van Ravenswaay Claasen HH, Witt F, Morlock MM, Vehmeijer SBW. Pseudotumor after bilateral ceramic-on-metal total hip arthroplasty: a case report. J Bone Joint Surg. 2014;4(1):1–6.

    Article  Google Scholar 

  19. Bosker BH, Ettema HB, Boomsma MF, Kollen BJ, Maas M, Verheyen CC. High incidence of pseudotumour formation after large-diameter metal-on-metal total hip replacement: a prospective cohort study. J Bone Joint Surg (Br). 2012;94(6):755–61.

    Article  CAS  Google Scholar 

  20. Lakstein D, Eliaz N, Levi O, Backstein D, Kosashvili Y, Safir O, et al. Fracture of cementless femoral stems at the mid-stem junction in modular revision hip arthroplasty systems. J Bone Joint Surg Am. 2011;93(1):57–65.

    Article  PubMed  Google Scholar 

  21. Richards CJ, Duncan CP, Masri BA, Garbuz DS. Femoral revision hip arthroplasty: a comparison of two stem designs. Clin Orthop Relat Res. 2010;468(2):491–6.

    Article  PubMed Central  PubMed  Google Scholar 

  22. Schramm M, Wirtz DC, Holzwarth U, Pitto RP. The Morse taper junction in modular revision hip replacement—a biomechanical and retrieval analysis. Biomed Tech. 2000;45(4):105–9.

    Article  CAS  Google Scholar 

  23. Beaule PE, Kim PR, Hamdi A, Fazekas A. A prospective metal ion study of large-head metal-on-metal bearing: a matched-pair analysis of hip resurfacing versus total hip replacement. Orthop Clin N Am. 2011;42(2):251–7. ix.

    Article  Google Scholar 

  24. Garbuz DS, Tanzer M, Greidanus NV, Masri BA, Duncan CP. The John Charnley Award: Metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial. Clin Orthop Relat Res. 2010;468(2):318–25.

    Article  PubMed Central  PubMed  Google Scholar 

  25. Langton DJ, Sidaginamale R, Lord JK, Nargol AV, Joyce TJ. Taper junction failure in large-diameter metal-on-metal bearings. Bone Joint Res. 2012;1(4):56–63.

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  26. Langton D, Sidaginamale R, Lord J, Joyce T, Natu S, Nargol A. Metal debris release from taper junctions appears to have a greater clinical impact than debris released from metal on metal bearing surfaces. Bone Joint J. 2013;95-B(SUPP 1):28.

    Google Scholar 

  27. Hauptfleisch J, Pandit H, Grammatopoulos G, Gill HS, Murray DW, Ostlere S. A MRI classification of periprosthetic soft tissue masses (pseudotumours) associated with metal-on-metal resurfacing hip arthroplasty. Skelet Radiol. 2012;41(2):149–55.

    Article  Google Scholar 

  28. Anderson H, Toms AP, Cahir JG, Goodwin RW, Wimhurst J, Nolan JF. Grading the severity of soft tissue changes associated with metal-on-metal hip replacements: reliability of an MR grading system. Skelet Radiol. 2011;40(3):303–7.

    Article  Google Scholar 

  29. Thomas MS, Wimhurst JA, Nolan JF, Toms AP. Imaging metal-on-metal hip replacements: the Norwich experience. HSS J. 2013;9(3):247–56.

    Article  PubMed Central  PubMed  Google Scholar 

  30. Nawabi DH, Gold S, Lyman S, Fields K, Padgett DE, Potter HG. MRI predicts ALVAL and tissue damage in metal-on-metal hip arthroplasty. Clin Orthop Relat Res. 2014;472(2):471–81.

    Article  PubMed  Google Scholar 

  31. Meftah M, Nicolaou N, Rodriguez JA. Metal allergy response to femoral head-neck corrosion after total hip replacement. Current Orthopaedic Practice. 2010; 21(5):530–533 510.1097/BCO.1090b1013e3181e1056d1097d.

  32. Scully WF, Teeny SM. Pseudotumor associated with metal-on-polyethylene total hip arthroplasty. Orthopedics. 2013;36(5):e666–670.

    Article  PubMed  Google Scholar 

  33. Molloy DO, Munir S, Jack CM, Cross MB, Walter WL, Walter Sr WK. Fretting and corrosion in modular-neck total hip arthroplasty femoral stems. J Bone Joint Surg Am. 2014;96(6):488–93.

    Article  PubMed  Google Scholar 

  34. Arnholt CM, MacDonald D, Tohfafarosh M, Gilbert JL, Klein GR, Mont MA, et al. Mechanically assisted taper corrosion in modular total knee arthroplasty. American Academy of Orthopaedic Surgeons Annual Meeting March 11–15, 2014; New Orleans, LA. p. Paper No 318.

  35. McMaster WC, Patel J. Adverse local tissue response lesion of the knee associated with Morse taper corrosion. J Arthroplasty. 2013;28(2):375–8.

    Article  PubMed  Google Scholar 

  36. Amstutz HC, Le Duff MJ, Campbell PA, Wisk LE, Takamura KM. Complications after metal-on-metal hip resurfacing arthroplasty. Orthop Clin N Am. 2011;42(2):207–30. viii.

    Article  Google Scholar 

  37. Cipriano CA, Issack PS, Beksac B, Della Valle AG, Sculco TP, Salvati EA. Metallosis after metal-on-polyethylene total hip arthroplasty. Am J Orthop. 2008;37(2):E18–25.

    PubMed  Google Scholar 

  38. Hart A. Further Opinion: Mixing and matching causing taper wear. J Bone Joint Surg (Br). 2012;94-B(2):e1.

    Google Scholar 

Download references

Conflict of interest

No external funding support was provided for the production of this manuscript. The authors declare that they have no conflicts of interest.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ryan M. Shulman.

Additional information

Written consent for publication was obtained from the patient whose findings are described in the present report.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Shulman, R.M., Zywiel, M.G., Gandhi, R. et al. Trunnionosis: the latest culprit in adverse reactions to metal debris following hip arthroplasty. Skeletal Radiol 44, 433–440 (2015). https://doi.org/10.1007/s00256-014-1978-3

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00256-014-1978-3

Keywords

Navigation