Skip to main content
Log in

A quartz crystal microbalance-based Immunosensor for Shrimp Allergen Determination in Food

  • Original Paper
  • Published:
European Food Research and Technology Aims and scope Submit manuscript

Abstract

A rapid method for determination of food allergen was carried out by quartz crystal microbalance-based immunosensor in this paper, involving the use of polyclonal antibody specific to shrimp allergen based on antibody antigen reaction. Conditions of piezoelectric immunosensor for the analysis of shrimp allergen to be completed in less than 10 min were optimized. The rapid electrode modification was developed on the basis of self-assembly with 1,6-hexanedithiol (HDT) and nanogold. The optimum conditions for detection were as follows: 15 mM HDT was coated on the electrode for 90 min, and nanogold was adsorbed for 110 min at room temperature; the antibody was coated for 3 h under 4 °C, and the coating concentration for anti-shrimp antibody was 0.16 mg/mL, the detecting time was only 500s, and the standard curve between 1 and 300 μg/mL was obtained, in consistent with Sauerbrey equation. The detection limit is 0.333 μg/mL. The recovery of immunosensor was in the range of 96.53–106.22% with coefficient of variation (CV) 6.46–8.89%. Regeneration of the electrode was also studied: piranha and strong alkali and acid had obvious effect, and the electrode can be reused for more than 13 times; glycine had less regeneration capacity for 5 times, but more conveniently. The present immunosensor has showed good performance for application in detection of shrimp allergen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

References

  1. Sicherer SH, Muñoz-Furlong A, Sampson HA (2004) J Allergy Clin Immunol 114:159–165

    Article  Google Scholar 

  2. Leung PS, Chu KH, Chow WK, Ansari A, Bandea CI, Kwan HS, Nagy SM, Gershwin ME (1994) J Allergy Clin Immunol 94:880–890

    Article  Google Scholar 

  3. Thompson T, Kane RR, Hager MH (2006) J Am Diet Assoc 106:1742–1744

    Article  Google Scholar 

  4. Poms RE, Klein CL, Anklam E (2004) Food Addit Contam 21:1–31

    Article  CAS  Google Scholar 

  5. Poms RE, Anklam E, Emons H (2006) Reference materials and method validation, in detecting food allergens. In: Hefle S, Koppelman S (eds) Woodhead Publishing Ltd., Cambridge, UK, pp 348–356

  6. Berglin M, Andersson M, Sellborn A, Elwing H (2004) Biomaterials 25:4581–4590

    Article  CAS  Google Scholar 

  7. Hemmersam AG, Foss M, Chevallier J, Besenbacher F (2005) Colloids Surf B Biointerfaces 43:208–215

    Article  CAS  Google Scholar 

  8. Marx KA, Zhou T, Montrone A, McIntosh D, Braunhut SJ (2007) Anal Biochem 361:77–92

    Article  CAS  Google Scholar 

  9. Sauerbrey G (1959) J Phys 155:206–222

    CAS  Google Scholar 

  10. Karamollaoğlu İ, Öktem HA, Mutlu M (2009) Biochem Eng J 44:142–150

    Article  Google Scholar 

  11. Mannelli I, Minunni M, Tombelli S, Mascini M (2003) Biosens Bioelectron 18:129–140

    Article  CAS  Google Scholar 

  12. Gomes M, Nogueira PST, Oliveira JABP (2000) Sensors and Actuators B:218–222

    Google Scholar 

  13. Lam KB, Irwin EF, Healy KE, Lin L (2006) Sens Actuators B Chem 117:480–487

    Article  Google Scholar 

  14. Hook F, Kasemo B, Nylander T, Fant C, Sott K, Elwing H (2001) Anal Chem 73:5796–5804

    Article  CAS  Google Scholar 

  15. Larsson C, Bramfeldt H, Wingren C, Borrebaeck C, Höök F (2005) Anal Biochem 345:72–80

    Article  CAS  Google Scholar 

  16. Limsona J, Odunugaa OO, Greenb H, Höökc F, Blatch GL (2004) S Afr J Sci 100:678–682

    Google Scholar 

  17. Lord MS, Modin C, Foss M, Duch M, Simmons A, Besenbacher F, Milthorpe BK (2006) Biomaterials 27:4529–4537

    Article  CAS  Google Scholar 

  18. Modin C, Stranne A-L, Foss M, Duch M, Justesen J, Chevallier J, Andersen LK, Hemmersam AG, Pedersen FS, Besenbacher F (2006) Biomaterials 27:1346–1354

    Article  CAS  Google Scholar 

  19. Tang D-Q, Zhang D-J, Tang D-Y, Ai H (2006) J Immunol Methods 316:144–152

    Article  CAS  Google Scholar 

  20. Kurosawa S, Nakamura M, Park J-W, Aizawa H, Yamada K, Hirata M (2004) Biosens Bioelectron 20:1134–1139

    Article  CAS  Google Scholar 

  21. Bourgeat-Lami E (2002) J Nanosci Nanotechnol 2:1–24

    Article  CAS  Google Scholar 

  22. Tang FQ, Li JR, Zhang L, Jiang L (1992) Biosens Bioelectron 7:503–507

    Article  CAS  Google Scholar 

  23. Chu X, Zhao Z-L, Shen G-L, Yu R-Q (2006) Sens Actuators B Chem 114:696–704

    Article  Google Scholar 

  24. Tripathi VS, Kandimalla VB, Ju H (2006) Sens Actuators B Chem 114:1071–1082

    Article  Google Scholar 

  25. Kim YP, Oh E, Hong MY, Lee D, Han MK, Shon HK, Moon DW, Kim HS, Lee TG (2006) Anal Chem 78:1913–1920

    Article  CAS  Google Scholar 

  26. Zhenxing L, Hong L, Limin C, Jamil K (2006) Eur Food Res Technol 223:639–644

    Article  Google Scholar 

  27. Lu G, Liu B, Liu C, Wang D, Cao M (1995) Chin J Biotechnol 11:253–258

    CAS  Google Scholar 

  28. Zhu L, Chen X (2000) Experimental methods of immunology. Public of Army Press, Beijing, pp 99–110

    Google Scholar 

  29. Asturias JA, Gomez-Bayon N, Arilla MC, Martínez A, Palacios R, Sánchez-Gascón F, Martínez J (1999) J Immunol 162:4342–4348

    CAS  Google Scholar 

  30. Martínez A, Martínez J, Palacios R, Panzani R (1997) Allergol Immunopathol (Madr) 25: 118–126

    Google Scholar 

Download references

Acknowledgments

The authors thank Professor Li Zaijun, for the technical advice and assistance. We also thank the Suwei Research Ltd. of Microbiology of Jiang Su Province for supplying the research instruments. This research was supported by Projects of National nature project (20806033), project (2007AA10Z428, 2006AZ02 and SKLF-20092060204). This article was also supported by 111 project –B07029 and PCSIRT0627.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sun Xiulan.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Xiulan, S., Yinzhi, Z., Jingdong, S. et al. A quartz crystal microbalance-based Immunosensor for Shrimp Allergen Determination in Food. Eur Food Res Technol 231, 563–570 (2010). https://doi.org/10.1007/s00217-010-1305-8

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00217-010-1305-8

Keywords

Navigation