Skip to main content
Log in

Spatially and angularly resolved spectroscopy for in-situ estimation of concentration and particle size in colloidal suspensions

  • Research Paper
  • Published:
Analytical and Bioanalytical Chemistry Aims and scope Submit manuscript

Abstract

Successful implementation of process analytical technology (PAT) hinges on the ability to make continuous or frequent measurements in-line or at-line of critical product attributes such as composition and particle size, the latter being an important parameter for particulate processes such as suspensions and emulsions. A novel probe-based spatially and angularly-resolved diffuse reflectance measurement (SAR-DRM) system is proposed. This instrument, along with appropriate calibration models, is designed for online monitoring of concentration of chemical species and particle size of the particulate species in process systems involving colloidal suspensions. This measurement system was investigated using polystyrene suspensions of various particle radius and concentration to evaluate its performance in terms of the information obtained from the novel configuration which allows the measurement of a combination of incident light at different angles and collection fibres at different distances from the source fibres. Different strategies of processing and combining the SAR-DRM measurements were considered in terms of the impact on partial least squares (PLS) model performance. The results were compared with those obtained using a bench-top instrument which was used as the reference (off-line) instrument for comparison purposes. The SAR-DRM system showed similar performance to the bench top reference instrument for estimation of particle radius, and outperforms the reference instrument in estimating particle concentration. The investigation shows that the improvement in PLS regression model performance using the SAR-DRM system is related to the extra information captured by the SAR-DRM configuration. The differences in SAR-DRM spectra collected by the different collection fibres from different angular source fibres are the dominant reason for the significant improvement in the model performance. The promising results from this study suggest the potential of the SAR-DRM system as an online monitoring tool for processes involving suspensions.

A probe designed to acquire diffuse reflectance measurements at different source-detector distances for three incidence angles 0°, 30° and 45° was used to estimate particle size and concentration of polystyrene beads in aqueous suspension using partial least squares calibration models.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Administration, U.S.F.a.D., Guidance for Industry PAT—A Framework for Innovative Pharmaceutical Development, Manufacturing, and Quality Assurance. Rockville, MD; 2004.

  2. Agency EM. Guideline on the use of near infrared spectroscopy by the pharmaceutical industry and the data requirements for new submissions and variations. London, UK; 2014.

  3. De Beer T, Burggraeve A, Fonteyne M, Saerens L, Remon JP, Vervaet C. Near infrared and Raman spectroscopy for the in-process monitoring of pharmaceutical production processes. Int J Pharm. 2011;417(1–2):32–47.

    Article  Google Scholar 

  4. Geladi P, MacDougall D, Martens H. Linearization and scatter-correction for near-infrared reflectance spectra of meat. Appl Spectrosc. 1985;39:491–500.

    Article  Google Scholar 

  5. Barnes RJ, Dhanoa MS, Lister SJ. Standard normal variate transformation and de-trending of near-infrared diffuse reflectance spectra. Appl Spectrosc. 1989;43:772–7.

    Article  CAS  Google Scholar 

  6. Martens H, Nielsen JP, Engelsen SB. Light scattering and light absorbance separated by extended multiplicative signal correction application to near-infrared transmission analysis of powder mixtures. Anal Chem. 2003;75:394–404.

    Article  CAS  Google Scholar 

  7. Norris KH, Williams PC. Optimization of mathematical treatments of raw near-infrared signal in the measurement of protein in hard red spring meat. 1. Influence of particle size. Cereal Chem. 1984;61(12):158–65.

    CAS  Google Scholar 

  8. Pedersen DJ, Martens H, Nielsen JP, Engelsen SB. Near-infrared absorption and scattering separated by extended inverted signal correction (EISC): analysis of near-infrared transmittance spectra of single wheat seeds. Appl Spectrosc. 2002;56:1206–14.

    Article  CAS  Google Scholar 

  9. Svensson O, Kourti T, MacGregor JF. An investigation of orthogonal signal correction algorithms and their characteristics. J Chemom. 2002;16:176–88.

    Article  CAS  Google Scholar 

  10. Chen Z-P, Morris J, Martin E. Extracting chemical information from spectral data with multiplicative light scattering effects by optical path-length estimation and correction. Anal Chem. 2006;78(22):7674–81.

    Article  CAS  Google Scholar 

  11. Rinnan A, Berg FVD, Engelsen SB. Review of the most common pre-processing techniques for near-infrared spectra. Trends Anal Chem. 2009;28(10):1201–22.

    Article  CAS  Google Scholar 

  12. Steponavicius R, Thennadil SN. Extraction of chemical information of suspensions using radiative transfer theory to remove multiple scattering effects: application to a model two-component system. Anal Chem. 2009;81(18):7713–23.

    Article  CAS  Google Scholar 

  13. Steponavicius R, Thennadil SN. Extraction of chemical information of suspensions using radiative transfer theory to remove multiple scattering effects: application to a model multicomponent system. Anal Chem. 2011;83(6):1931–7.

    Article  CAS  Google Scholar 

  14. Steponavicius R, Thennadil SN. Full correction of scattering effects by using the radiative transfer theory for improved quantitative analysis of absorbing species in suspensions. Appl Spectrosc. 2013;67(5):526–35.

    Article  CAS  Google Scholar 

  15. Utzinger U, Richards-Kortum RR. Fiber optic probes for biomedical optical spectroscopy. J Biomed Opt. 2003;8(1):121–47.

    Article  Google Scholar 

  16. Doornbos RMP, Lang R, Aalders MC, Cross MW, Sterenborg HJ. The determination of in vivo human tissue optical properties and absolute chromophore concentrations using spatially resolved steady-state diffuse reflectance spectroscopy. Phys Med Biol. 1999;44(4):967–81.

    Article  CAS  Google Scholar 

  17. Groenhuis RAJ, Ferwerda HA, Ten JJ. Scattering and absorption of turbid materials determined from reflection measurements. 1: Theory. Appl Opt. 1983;22(16):2456–62.

    Article  CAS  Google Scholar 

  18. Groenhuis RAJ, Ferwerda HA, Ten JJ. Scattering and absorption of turbid materials determined from reflection measurements. 2: Measuring method and calibration. Appl Opt. 1983;22(16):2463–7.

    Article  CAS  Google Scholar 

  19. Farrell TJ, Patterson MS. A diffusion theory model of spatially resolved, steady-state diffuse reflectance for the noninvasive determination of tissue optical properties in vivo. Med Phys. 1992;19:879–88.

    Article  CAS  Google Scholar 

  20. Dam JS, Dalgaard T, Fabricius PE, Andersson-Engels S. Multiple polynomial regression method for determination of biomedical optical properties from integrating sphere measurements. Appl Opt. 2000;39(7):1202–9.

    Article  CAS  Google Scholar 

  21. Thueler P, Charvet I, Bevilacqua F, St Ghislain M, Ory G, Marquet P, et al. In vivo endoscopic tissue diagnostics based on spectroscopic absorption, scattering, and phase function properties. J Biomed Opt. 2003;8(3):495–503.

    Article  Google Scholar 

  22. Farrell TJ, Wilson BC, Patterson MS. The use of a neural network to determine tissue optical properties from spatially resolved diffuse reflectance measurements. Phys Med Biol. 1992;37(12):2281–6.

    Article  CAS  Google Scholar 

  23. Dam JS, Andersen PE, Dalgaard T, Fabricius PE. Determination of tissue optical properties from diffuse reflectance profiles by multivariate calibration. Appl Opt. 1998;37(4):772–8.

    Article  CAS  Google Scholar 

  24. Watté R, Aernouts B, Van Beers R, Saeys W. Robust metamodel-based inverse estimation of bulk optical properties of turbid media from spatially resolved diffuse reflectance measurements. Opt Mat Exp. 2015;5(11):27880–98.

    Article  Google Scholar 

  25. Dehanov, N., Thennadil, S. N., Monitoring of mean particle size during emulsion polymerisation reactions using visible and near infrared diffuse reflectance spectroscopy. Asia Pacific Conf Chem Eng Cong. 2015 (APCChE 2015) incorporating CHEMECA 2015 / IChemE; EA. ISBN 9781922107473. Library Australia ID 54817420.

  26. Thennadil SN, Chen Y-C. Measurement apparatus and method with variable path lengths and variable reflective surfaces. Patent Application, GB2496690. Date of Filing, 21/11/2011.

  27. Thennadil SN, Martin EB. Empirical pre-processing methods and their impact on NIR calibrations: a simulation study. J Chemom. 2005;19(2):77–89.

    Article  CAS  Google Scholar 

Download references

Acknowledgements

The authors would like to acknowledge funding received from the Scottish Enterprise Proof of Concept Programme.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Suresh N. Thennadil.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Additional information

Published in the topical collection Process Analytics in Science and Industry with guest editor Rudolf W. Kessler.

Electronic supplementary material

ESM 1

(PDF 464 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chen, YC., Foo, D., Dehanov, N. et al. Spatially and angularly resolved spectroscopy for in-situ estimation of concentration and particle size in colloidal suspensions. Anal Bioanal Chem 409, 6975–6988 (2017). https://doi.org/10.1007/s00216-017-0672-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00216-017-0672-4

Keywords

Navigation