Skip to main content
Log in

Liquid chromatography with triple-quadrupole or quadrupole-time of flight mass spectrometry for screening and confirmation of residues of pharmaceuticals in water

  • Original Paper
  • Published:
Analytical and Bioanalytical Chemistry Aims and scope Submit manuscript

Abstract

LC–MS–MS has been performed with triple-quadrupole (QqQ) and quadrupole-time of flight (Q-ToF) instruments and has been used for screening and confirmation of pharmaceuticals in surface, drinking, and ground water. Screening was based on monitoring of one specific MS–MS ion of the target compounds. Confirmation of the identity of the pharmaceuticals was based either on the monitoring of two specific MS–MS ions and calculation of the ratio of their intensities, or on the exact masses of MS–MS product ions obtained for a molecular ion by use of LC–Q-ToF MS. The set of pharmaceuticals included four analgesics (acetylsalicylic acid, diclofenac, ibuprofen, and paracetamol), three antibiotics (sulfamethoxazole, erythromycin, and chloramphenicol), five blood-lipid regulators and beta-blockers (fenofibrate, bezafibrate, clofibric acid, bisoprolol, and metoprolol), and the anti-epileptic drug carbamazepine. Limits of quantification ranged from 5 to 25 ng L−1. Fifty-six samples were analysed and residues of the pharmaceuticals were detected in almost all surface and groundwater and in some drinking water samples. The identity of the compounds could be confirmed by use of both QqQ- and Q-ToF-based LC–MS–MS. However, the latter technique has the distinct advantage that a large number of pharmaceuticals can be screened and confirmed at low concentrations (1–100 ng L−1) in one run.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Kümmerer K (2001) Chemosphere 45:957–969

    Article  PubMed  Google Scholar 

  2. Hirsch R, Ternes T, Haberer K, Kratz KL (1999) Sci Total Environ 225:109–118

    Article  CAS  PubMed  Google Scholar 

  3. Derksen JGM, van Eijnatten GM, Lahr J, van der Linde P, Kroon AGM, (2002) RIZA report: 2001.051, ISBN: 903695391x, Nieuwegein, the Netherlands

  4. Sacher F, Lange FTh, Brauch HJ, Blankenhorn I (2001) J Chromatogr A 938:199–210

    Article  CAS  PubMed  Google Scholar 

  5. Öllers S, Singer HP, Fässler P, Müller SR (2001) J Chromatogr A 911:225–234

    Article  PubMed  Google Scholar 

  6. Ternes T, Bonerz M, Schmidt T (2001) J Chromatogr A 938:175–185

    Article  CAS  PubMed  Google Scholar 

  7. La Farré M, Ferrer I, Ginebreda A, Figueras M, Olivella L, Tirapu L, Vilanova M, Barceló D (2001) J Chromatogr A 938:187–197

    Article  PubMed  Google Scholar 

  8. Ahrer W, Scherwenk W, Buchberger W (2001) J Chromatogr A 910:69–78

    Article  CAS  PubMed  Google Scholar 

  9. Hartig C, Storm T, Jekel M (1999) J Chromatogr A 854:163–173

    Article  CAS  PubMed  Google Scholar 

  10. Hirsch R, Ternes ThA, Haberer K, Mehlich A, Ballwanz F, Kratz KL (1998) J Chromatogr A 815:213–223

    Article  CAS  PubMed  Google Scholar 

  11. Carson MC, Bullock G, Bebak-Williams J (2002) J Assoc Off Anal Chem Int 85:341–348

    CAS  Google Scholar 

  12. Miao XS, Koenig BG, Metcalfe CD (2002) J Chromatogr A 952:139–147

    Article  CAS  PubMed  Google Scholar 

  13. Official Journal of the European Communities L221, 8–36, Commission Decision (2002/657/EC) of 12 August 2002 concerning the performance of analytical methods and the interpretation of results, Brussels, Belgium

  14. Bobeldijk I, Vissers JPC, Kearney G, Major H, van Leerdam JA (2001) J Chromatogr A 929:63–74

    Article  CAS  PubMed  Google Scholar 

  15. Wolff JC, Eckers C, Sage AB, Giles K, Bateman R (2001) Anal Chem 73:2605–2612

    CAS  PubMed  Google Scholar 

  16. Nielen MWF, Vissers JPC, Fuchs REM, van Velde JW, Lommen A (2001) Rapid Commun Mass Spectrom 15:1577–1585

    Article  CAS  PubMed  Google Scholar 

  17. Hogenboom AC, Hofman MP, Kok SJ, Niessen WMA, Brinkman UATh (2000) J Chromatogr A 892:379–390

    CAS  PubMed  Google Scholar 

  18. Ternes ThA (2001) Trends Anal Chem (2001) 20:419–434

  19. Flaherty S, Wark S, Street G, Farley JW, Brumley WC (2002) Electrophoresis 23: 2327–2332

    Article  CAS  PubMed  Google Scholar 

  20. Matuszewski BK, Constanzer ML, Chavez-Eng CM (2003) Anal Chem 75:3019–3030

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgement

The authors wish to thank Mr M. van Oosterhout and Dr R.J. Vreeken for arranging the LC–Q-ToF MS experiments.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alida A. M. Stolker.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Stolker, A.A.M., Niesing, W., Hogendoorn, E.A. et al. Liquid chromatography with triple-quadrupole or quadrupole-time of flight mass spectrometry for screening and confirmation of residues of pharmaceuticals in water. Anal Bioanal Chem 378, 955–963 (2004). https://doi.org/10.1007/s00216-003-2253-y

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00216-003-2253-y

Keywords

Navigation