Hand–eye calibration and positioning for a robot drilling system

  • ORIGINAL ARTICLE
  • Published:
The International Journal of Advanced Manufacturing Technology Aims and scope Submit manuscript

Abstract

In the aircraft manufacturing, drilling large amount of assembly holes in aircraft board is one of the key bottlenecks of production efficiency. To enhance the efficiency and quality of assembly holes' manufacturing, robot drilling system replacing manual operation becomes more and more urgent. Normally, a robot system needs accurate mathematical models of the manufactured object and the environment when it's working; as a matter of fact, because of the manufacturing error, the homogeneity between aircraft board and its mathematical model is dissatisfied. So a hand–eye vision system is introduced to realize the positioning of the end effector in order to improve the flexibility and robustness of a robot drilling system. The paper discusses the calibration and positioning of a hand–eye vision system for a robotic aircraft board drilling system. Because the drill must be vertical and keep a fixed distance to the aircraft board surface before drilling, the depth information of hand–eye relationship is neglected and by defining an intermediate scene coordinate system the hand–eye relationship between the robot coordinate system and the vision coordinate system is established. Then the position of target point can be described in the robot coordinate system by using the calibrated hand–eye relationship, and thus the navigation information for the robot drilling system can be provided. Experimental results of the calibration and positioning of the hand–eye vision of a robot drilling system is provided, and the main factors that affect the positioning error are analyzed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Eriksson T, Hansen HN, Gegeckaite A (2008) On the use of industrial robots in microfactories. Int J Adv Manuf Technol 38:479–486

    Article  Google Scholar 

  2. Bi SS, Liang J (2011) Robotic drilling system for titanium structures. Int J Adv Manuf Technol 54:767–774

    Article  Google Scholar 

  3. Ding LM (1990) The application of robot in aviation industry. Robot Inf 30:1–11

    Google Scholar 

  4. Russell DV, Kevin S, Ed F, John I (2001) ONCE (one sided cell end effector) robotic drilling system: 01–2626

  5. Tsal RY, Lanz RK (1989) A new technique for fully autonomous and efficient 3D robotics hand–eye calibration. IEEE JNL 5:345–358. doi:10.1109/70.34770

    Google Scholar 

  6. Shiu YC, Ahmad S (1989) Calibration of wrist-mounted robotic sensors by solving homogeneous transform equations of the form AX = XB. IEEE JNL 5:16–19. doi:10.1109/70.88014

    Google Scholar 

  7. Tsai RY (1987) A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses. IEEE JNL 4:323–344. doi:10.1109/JRA.1987.1087109

    Google Scholar 

  8. Weng J, Cohen P, Herniou M (1992) Camera calibration with distortion models and accuracy evaluation. IEEE JNL 14:965–980. doi:10.1109/34.159901

    Google Scholar 

  9. Zhang Z (1999) Flexible camera calibration by viewing a plane from unknown orientations. IEEE CNF 1:666–673. doi:10.1109/ICCV.1999.791289

    Google Scholar 

  10. Tsai RY (1986) An efficient and accurate camera calibration technique for 3D machine vision. Proc IEEE CNF. pp 364–374

  11. Malm H, Heyden A (2000) A new approach to hand–eye calibration. IEEE CNF 1:525–529. doi:10.1109/ICPR.2000.905391

    Google Scholar 

  12. Wang HX, Li XR, Su XC, Cao MY (2007) Applied positioning method for hand–eye vision system. CE&A 24:235–238

    Google Scholar 

  13. Liu SY, Wang GR, Shi YH (2008) Simultaneous calibration of camera and hand–eye in robot welding with laser vision. J South Chin Univ Tech 2:75–77

    Google Scholar 

  14. Yang GL, Kong LF, Wang J (2006) A new calibration approach to hand–eye relationship of manipulator. Robot 4:401–405

    Google Scholar 

  15. Ma SD, Zhang ZY (1998) Computer vision: computational theory and algorithm. Science, Beijing

  16. Ma SD (1996) A self-calibration technique for active vision system. IEEE JNL 1:114–120. doi:10.1109/70.481755

    Google Scholar 

  17. Wang HX, Wang CY, Lu X (2007) Self-calibration technique based on hand–eye vision systems. IEEE CNF pp. 212–215 doi:10.1109/CHICC.2006.4347411

  18. Maybank SJ, Faugeras OD (1992) A theory of self-calibration of a moving camera. Int J Comput Vis 2:123–151

    Article  Google Scholar 

  19. Hu ZY, Wu FC (2002) A review on some active vision based camera calibration techniques. Chin J Comput 11:1149–1156

    MathSciNet  Google Scholar 

  20. Wei G, Arbter K, Hirzinger G (1998) Active self-calibration of robotic eyes and hand–eye relationships with model identification. IEEE JNL 14:158–166. doi:10.1109/70.660864

    Google Scholar 

  21. Hanqi Z, Roth ZS, Sudhakar R (1994) Simultaneous robot/world and tool/flange calibration by solving homogeneous transformation equations of the form AX = YB. EEE JNL 4:49–554

    Google Scholar 

  22. Domaika F, Horand R (1998) Simultaneous robot-world and hand–eye calibration. IEEE JNL 4:617–622. doi:10.1109/70.704233

    Google Scholar 

  23. Zhang GJ (2005) Machine vision. Science, Beijing

  24. Product manuals (2004) ABB robot document IRB 1410 M2004

  25. Meng LB, Jin GC, Yao XF (2006) Errors caused by misalignment of the optical camera axis and the object surface in the DSCM. Tsinghua Sci Technol 11:1930–1932

    Article  Google Scholar 

  26. Product specifications (2004) ABB robot document IRB 6640 M2004

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Qiang Zhan.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zhan, Q., Wang, X. Hand–eye calibration and positioning for a robot drilling system. Int J Adv Manuf Technol 61, 691–701 (2012). https://doi.org/10.1007/s00170-011-3741-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00170-011-3741-4

Keywords

Navigation