Abstract
Our goal was to determine the primary stability of overlapping osteochondral grafts used in mosaicplasty by studying the effect of overlapping in an ex vivo model. Osteochondral grafts, 10 mm in diameter, were transplanted from the trochlea of cow femurs to the weight-bearing area of the lateral femoral condyle with 0, 15, or 30% overlap. The grafts were pushed in with a probe at a rate of 2 mm/min, and load (N)–displacement (mm) curves were recorded. In Group I (control, 0% overlap), insertion 1 and 2 mm below the cartilage level could be reached at 572.3 ± 273.6 and 999.3 ± 427.6 N, respectively. In Group II (15% overlap), insertion 1 and 2 mm below the cartilage level could be reached at 263.6 ± 91.7 and 746.6 ± 88.0 N, respectively. In Group III (30% overlap), insertion 1 and 2 mm below the cartilage level could be reached at 179.4 ± 31.2 and 657.0 ± 106.5 N, respectively. The loads that were necessary to produce a 1-mm dent in the grafts were significantly different between Groups I and II and Groups I and III (p < 0.05). These results suggest that stability may be reduced by graft overlapping in mosaicplasty surgery. The results of this ex vivo animal study contribute to a more complete understanding of the primary stability of osteochondral grafts in an overlapping position as well as postoperative protocols.
Similar content being viewed by others
References
Hangody L, Feczko P, Bartha L, Bodo G, Kish G (2001) Mosaicplasty for the treatment of articular defects of the knee and ankle. Clin Orthop 391(suppl):328–336
Hangody L, Rathonyi G, Duska Z, Vasarhelyi G, Fules P, Modis L (2004) Autologous osteochondral mosaicplasty. J Bone Joint Surg Am 86:65–72
Kordas G, Szabo JS, Hangody L (2005) The effect of drill-hole length on the primary stability of osteochondral grafts in mosaicplasty. Orthopedics 28:401–404
Kordas G, Szabo JS, Hangody L (2006) Primary stability of osteochondral grafts used in mosaicplasty. Arthroscopy 22:414–421
Duchow J, Hess T, Kohn D (2000) Primary stability of pres-fit implanted osteochondral grafts. Influence of graft size, repeated insertion, and harvesting technique. Am J Sports Med 28:24–27
Whiteside RA, Bryant JT, Jakob RP, Mainil-Varlet P, Wyss UP (2003) Short-term load bearing capacity of osteochondral autografts implanted by the mosaicplasty technique: an in vitro porcine model. J Biomech 36:1203–1208
Berlet GC, Mascia A, Miniaci A (1999) Treatment of unstable osteochondritis dissecans lesions of the knee using autogenous osteochondral grafts (mosaicplasty). Arthroscopy 15:312–316
Martinez SA, Walker T (1999) Bone grafts. Vet Clin North Am Small Anim Pract 29:1207–1219
Quinn TM, Allen RG, Schalet BJ, Perumbuli P, Hunziker EB (2001) Matrix and cell injury due to sub-impact loading of adult bovine articular cartilage explants: effects of strain rate and peak stress. J Orthop Res 19:242–249
Linde F, Hvid I, Madsen F (1992) The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens. J Biomech 25:359–368
Conflict of interest statement
Each author certifies that he has no commercial association that might pose a conflict of interest in connection with the submitted article.
Author information
Authors and Affiliations
Corresponding author
Additional information
No benefits or funds were received in support of this study
Rights and permissions
About this article
Cite this article
Haklar, U., Tuzuner, T., Uygur, I. et al. The effect of overlapping on the primary stability of osteochondral grafts in mosaicplasty. Knee Surg Sports Traumatol Arthr 16, 651–654 (2008). https://doi.org/10.1007/s00167-008-0526-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00167-008-0526-x