Abstract
Current treatments for gait pathologies associated with neuromuscular disorders may employ a passive, rigid brace. While these provide certain benefits, they can also cause muscle atrophy. In this study, we examined NiTi shape memory alloy (SMA) wires that were annealed into springs to develop an active, soft orthotic (ASO) for the knee. Actively controlled SMA springs may provide variable assistances depending on factors such as when, during the gait cycle, the springs are activated; ongoing muscle activity level; and needs of the wearer. Unlike a passive brace, an active orthotic may provide individualized control, assisting the muscles so that they may be used more appropriately, and possibly leading to a re-education of the neuro-motor system and eventual independence from the orthotic system. A prototype was tested on a suspended, robotic leg to simulate the swing phase of a typical gait. The total deflection generated by the orthotic depended on the knee angle and the total number of actuators triggered, with a max deflection of 35°. While SMA wires have a high energy density, they require a significant amount of power. Furthermore, the loaded SMA spring response times were much longer than the natural frequency of an average gait for the power conditions tested. While the SMA wires are not appropriate for correction of gait pathologies as currently implemented, the ability to have a soft, actuated material could be appropriate for slower timescale applications.
Similar content being viewed by others
References
F. Miller, Cerebral Palsy, Springer, New York, NY, 2005
S. Hesse, C. Werner, K. Matthias, K. Stephen, and M. Berteanu, Non-Velocity-Related Effects of a Rigid Double-Stopped Ankle-Foot Orthosis on Gait and Lower Limb Muscle Activity of Hemiparetic Subjects with an Equinovarus Deformity, Stroke, 1999, 30(9), p 1855–1861
C. Morris, A Review of the Efficacy of Lower-Limb Orthoses Used for Cerebral Palsy, Dev. Med. Child Neurol., 2002, 44(3), p 205–211
M. Matthews, M. Watson, and G. Richardson, Effects of Dynamic Elastomeric Fabric Orthoses on Children with Cerebral Palsy, J. Prosthet. Orthot. Int., 2009, 33(4), p 339–347
J. Blaya and H. Herr, Adaptive Control of a Variable-Impedance Ankle-Foot Orthotis to Assist Drop-Foot Gait, IEEE Trans. Neural Syst. Rehabil. Eng., 2004, 12(1), p 24–31
A. Dollar and R. Howe, The Highly Adaptive SDM Hand: Design and Performance Evaluation, Int. J. Robot. Res., 2010, 29(5), p 585–597
K. O’Toole, M. McGrath, and E. Coyle, Analysis and Evaluation of the Dynamic Performance of SMA Actuators for Prosthetic Hand Design, J. Mater. Eng. Perform., 2009, 18(5–6), p 781–786
S. Pittaccio and S. Viscuso, An EMG-Controlled SMA Device for the Rehabilitation of the Ankle Joint in Post-Acute Stroke, Proceedings of the International Organization on Shape Memory and Superelastic Technologies, 16–20 May, 2010, p 40–41
H. Cheng, L. Obergefell, and A. Rizer, “Generator of Body Data (GEBOD), Manual,” AL/CF-TR-1994-0051, Wright-Patterson AFB, OH, March 1994
H. Cheng, L. Obergefell, and A. Rizer, The Development of the GEBOD Program, Proceedings of the Fifteenth Southern Biomedical Engineering Conference, 1996, p 251–254
R. Snyder, L. Schneider, C. Owings, H. Reynolds, H. Golomb, and A. Schork, “Anthropometry of Infants, Children, and Youths to Age 18 for Product Safety Design,” UM-HSRI-77-17, Bethseda, MD, May 1977
J. Pratt, B. Krupp, and C. Morse, Series Elastic Actuators for High Fidelity Force Control, Ind. Robot, 2002, 29(3), p 234–241
G. Pratt and M. Williamson, Series Elastic Actuators, Proceedings of the IEEE International Conference on Intelligent Robots and Systems, Vol 1, 1995, p 399–406
S. Kim, E. Hawkes, K. Cho, M. Jolda, J. Foley, and R. Wood, Micro Artificial Muscle Fiber Using NiTi Spring for Soft Robotics, Proceedings of the IEEE/RSJ International Conference on Intelligent Robots and Systems, 11–15 October 2009, p 2228–2234
K. Cho, E. Hawkes, C. Quinn, and R. Wood, A Design, Fabrication and Analysis of a Body-Caudal Fin Propulsion System for a Microrobotic Fish, Proceedings of the IEEE International Conference on Robotics and Automation, 19–23 May 2008, p 706–711
M. Murray, P. Drought, and R. Kory, Walking Patterns of Normal Men, J. Bone Joint Surg., 1964, 46(2), p 335–360
M. Gharaybeh and G. Burdea, Investigation of a Shape Memory Alloy Actuator for Dexterous Force-Feedback Masters, Adv. Robot., 1995, 9(3), p 317–329
G. Webb, L. Wilson, D. Lagoudas, and O. Rediniotis, Adaptive Control of Shape Memory Alloy Actuators for Underwater Biomimetic Applications, AIAA J., 2000, 38(2), p 325–334
P. Wellman, W. Peine, G. Favalora, and R. Howe, Mechanical Design and Control of a High-Bandwidth Shape Memory Alloy Tactile Display, Exp. Robot. V, 1998, 232, p 56–66
Acknowledgment
This research has been funded by the Wyss Institute at Harvard University.
Author information
Authors and Affiliations
Corresponding author
Additional information
This article is an invited paper selected from presentations at Shape Memory and Superelastic Technologies 2010, held May 16-20, 2010, in Pacific Grove, California, and has been expanded from the original presentation.
Rights and permissions
About this article
Cite this article
Stirling, L., Yu, CH., Miller, J. et al. Applicability of Shape Memory Alloy Wire for an Active, Soft Orthotic. J. of Materi Eng and Perform 20, 658–662 (2011). https://doi.org/10.1007/s11665-011-9858-7
Received:
Revised:
Published: