Skip to main content
Log in

Fluorescence Lifetime Correlation Spectroscopy

  • Original Paper
  • Published:
Journal of Fluorescence Aims and scope Submit manuscript

Abstract

This article explains the basic principles of FLCS, a genuine fusion of Time-Correlated Single Photon Counting (TCSPC) and Fluorescence Correlation Spectroscopy (FCS), using common terms and minimum mathematics. The usefulness of the method is demonstrated on simple FCS experiments. The method makes possible to separate the autocorrelation function of individual components of a mixture of fluorophores, as well as purging the result from parasitic contributions like scattered light or detector afterpulsing.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Böhmer M, Wahl M, Rahn H-J, Erdmann R, Enderlein J (2002) Time-resolved fluorescence correlation spectroscopy. Chem Phys Lett 353(5–6):439–445

    Article  Google Scholar 

  2. Benda A, Hof M, Wahl M, Patting M, Erdmann R, Kapusta P (2005) TCSPC upgrade of a confocal FCS microscope. Rev Sci Instrum 76(3):033106

    Article  CAS  Google Scholar 

  3. Enderlein J, Gregor I,(2005) Using fluorescence lifetime for discriminating detector afterpulsing in fluorescence-correlation spectroscopy. Rev Sci Instrum 76(3):033102

    Article  CAS  Google Scholar 

  4. Meseth U, Wohland Th, Rigler R, Vogel H (1999), Resolution of fluorescence correlation measurements. Biophys J 76(3):1619–1631

    PubMed  CAS  Google Scholar 

  5. Enderlein J, Erdmann R (1997) Fast fitting of multi-exponential decay curves. Opt Commun 134(1–6):371–378

    Article  CAS  Google Scholar 

  6. Wahl M, Koberling F, Patting M, Rahn H-J, Erdmann R (2004) Time-resolved confocal fluorescence imaging and spectroscopy system with single molecule sensitivity and sub-micrometer resolution. Curr Pharm Biotechnol 5(3):299–308

    Article  PubMed  CAS  Google Scholar 

  7. Böhmer M, Enderlein J (2003) Fluorescence spectroscopy of single molecules under ambient conditions: Methodology and technology. Chem Phys Chem 4(8):792-808

    Google Scholar 

  8. Böhmer M, Pampaloni F, Wahl M, Rahn H-J, Erdmann R, Enderlein J (2001) Time-resolved confocal scanning device for ultrasensitive fluorescence detection. Rev Sci Instrum 72(11):4145–4152

    Article  CAS  Google Scholar 

  9. Wahl M, Gregor I, Patting M, Enderlein J (2003), Fast calculation of fluorescence correlation data with asynchronous time-correlated single-photon counting. Opt Expr 11(26):3583–3591

    Article  Google Scholar 

  10. Lamb DC, Schenk A, Röcker C, Scalfi-Happ C, Nienhaus GU (2000) Sensitivity enhancement in fluorescence correlation spectroscopy of multiple species using time-gated detection. Biophys J 79(2):1129–1138

    Article  PubMed  CAS  Google Scholar 

  11. Benda A, Fagulova V, Deyneka A, Enderlein J, Hof M (2006) Fluorescence lifetime correlation spectroscopy combined with lifetime tuning: New perspectives in supported phospholipid bilayer research. Langmuir 22(23):9580–9585

    Google Scholar 

Download references

Acknowledgment

A.B. and M.H. acknowledge financial support by the Ministry of Education and Sport of the Czech Republic via grant LC06063.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Peter Kapusta.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kapusta, P., Wahl, M., Benda, A. et al. Fluorescence Lifetime Correlation Spectroscopy. J Fluoresc 17, 43–48 (2007). https://doi.org/10.1007/s10895-006-0145-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10895-006-0145-1

Keywords

Navigation