Skip to main content

Advertisement

Log in

In Vivo Tumour Mapping Using Electrocorticography Alterations During Awake Brain Surgery: A Pilot Study

  • Original Paper
  • Published:
Brain Topography Aims and scope Submit manuscript

Abstract

During awake brain surgery for tumour resection, in situ EEG recording (ECoG) is used to identify eloquent areas surrounding the tumour. We used the ECoG setup to record the electrical activity of cortical and subcortical tumours and then performed frequency and connectivity analyses in order to identify ECoG impairments and map tumours. We selected 16 patients with cortical (8) and subcortical (8) tumours undergoing awake brain surgery. For each patient, we computed the spectral content of tumoural and healthy areas in each frequency band. We computed connectivity of each electrode using connectivity markers (linear and non-linear correlations, phase-locking and coherence). We performed comparisons between healthy and tumour electrodes. The ECoG alterations were used to implement automated classification of the electrodes using clustering or neural network algorithms. ECoG alterations were used to image cortical tumours.Cortical tumours were found to profoundly alter all frequency contents (normalized and absolute power), with an increase in the δ activity and a decreases for the other bands (P < 0.05). Cortical tumour electrodes showed high level of connectivity compared to surrounding electrodes (all markers, P < 0.05). For subcortical tumours, a relative decrease in the γ1 band and in the alpha band in absolute amplitude (P < 0.05) were the only abnormalities. The neural network algorithm classification had a good performance: 93.6 % of the electrodes were classified adequately on a test subject. We found significant spectral and connectivity ECoG changes for cortical tumours, which allowed tumour recognition. Artificial neural algorithm pattern recognition seems promising for electrode classification in awake tumour surgery.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

Abbreviations

Δ:

Spectral content in the delta band in percent

θ:

Spectral content in the theta band in percent

α:

Spectral content in the alpha band in percent

β:

Spectral content in the beta band in percent

γ1 :

Spectral content in the gamma1 (<40 Hz) band in percent

LCorr:

Linear Correlation

H2Corr:

H2 Correlation

CohLF:

Coherence in the low frequencies (<4 Hz)

CohHF:

Coherence in high frequencies (4–40 Hz)

PLVLF:

Phase-Locking value in the low frequencies (<4 Hz)

PLVHF:

Phase-Locking value in the high frequencies (4–40 Hz)

PLI:

Phase lag index

References

Download references

Funding

this research received institutional funding by Assitance publique Hôpitaux de Marseille and Aix-Marseille University.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Salah Boussen.

Ethics declarations

Conflict of Interest

The authors have no conflict of interest.

Electronic Supplementary Material

Below is the link to the electronic supplementary material.

Supplementary material 1 (DOCX 180 kb)

Supplementary material 2 (DOCX 5472 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Boussen, S., Velly, L., Benar, C. et al. In Vivo Tumour Mapping Using Electrocorticography Alterations During Awake Brain Surgery: A Pilot Study. Brain Topogr 29, 766–782 (2016). https://doi.org/10.1007/s10548-016-0502-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10548-016-0502-6

Keywords

Navigation