Skip to main content
Log in

Semi-permanent transcorneal filter support and in vivo surgical implantation technique for open-angle glaucoma treatment

  • Published:
Biomedical Microdevices Aims and scope Submit manuscript

Abstract

Primary open-angle glaucoma is a progressive disease affecting nearly 60 million people worldwide which, if left untreated, can lead to optic nerve head damage and complete loss of sight. Current interventions include: pharmaceutical drops, laser surgery, shunts, and bleb; however, these methods provide insufficient long-term efficacy in intraocular pressure management. We developed a semi-permanent, implantable transcorneal duct as a new aid in the treatment of this disease. The duct, composed of an intracorneal stabilizing washer and hollow screw, creates an interface between the anterior chamber and the external environment, allowing for the outflow of excess aqueous humor. We discuss the fluid mechanics behind designing and implementing a filter material capable of preventing the ingress of bacteria and viruses while modifying aqueous humor outflow resistances to pre-glaucomatous levels, finding the effective radius of such a material to be 10.44 μm. After performing surgical implantation in four rabbit eyes, subsequent testing showed successful integration between the screw and washer. Colored saline injections highlighted fluid flow progression out of the eye through the duct, suggesting that the device may be a viable approach to treating high intraocular pressure created by open-angle glaucoma.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  • M.J. Bak, J.S. McIntosh, E.M. Scmidt, Long-term implants of parylene-c coated microelectrodes. Med. Biol. Eng. Comput. 26, 96–101 (1988)

    Article  Google Scholar 

  • G. Beidoe, S. Mousa, Current primary open-angle glaucoma treatments and future directions. Clin. Ophthalmol. 6, 1699–1707 (2012)

    Google Scholar 

  • R. Brubaker, Flow of aqueous humor in humans. Invest. Ophthalmol. Vis. Sci. 32, 3145–3166 (1991)

    Google Scholar 

  • T. Chan, S. Payor, B. Holden, Corneal thickness profiles in rabbits using an ultrasonic pachometer. Invest. Ophthalmol. Vis. Sci. 24(10), 1408–1410 (1983)

    Google Scholar 

  • H.D. Jampel, Guidelines on design and reporting of glaucoma surgical trials (Kugler, Amsterdam, 2009)

    Google Scholar 

  • V. Kapetanakis, M. Chan, P. Foster, D. Cook, C. Owen, A. Rudnicka, Global variations and time trends in the prevalence of primary open angle glaucoma (POAG): a systematic review and meta-analysis. British J. Ophthalmol. 100, 86–93 (2016)

    Article  Google Scholar 

  • D. Lee, E. Higginbotham, Glaucoma and its treatment: A review. Am. J. Health Syst. Pharm. 62(7), 691–699 (2005)

    Article  Google Scholar 

  • T. Leeungurasatien, P. Khunsongkiet, K. Pathanapitoon, D. Wiwatwongwana, Incidence of short-term complications and associated factors after primary trabeculectomy in Chiang Mai University Hospital. Indian J. Ophthalmol. 64(10), 737–742 (2016)

    Article  Google Scholar 

  • E.W. Leung, F.A. Medeiros, R.N. Weinreb, Prevalence of ocular surface disease in Glaucoma patients. J. Glaucoma 17(5), 350–355 (2008)

    Article  Google Scholar 

  • L. Levin, S. Nilsson, J. Ver Hoeve, S. Wu, P. Kaufman, A. Alm, Adler's physiology of the eye, Elsevier Inc., (2011)

  • N.P. Macdonald, F. Zhu, C.J. Hall, J. Reboud, P.S. Crosier, E.E. Patton, D. Wlodkowic, J.M. Cooper, Assessment of biocompatibility of 3D printed photopolymers using zebrafish embryo toxicity assays. Lab Chip 16(2), 291–297 (2016)

    Article  Google Scholar 

  • J. I. Orlando, Machine learning for ophthalmic screening and diagnostics from fundus images. KU Leuven, National University of Central Buenos Aires, (2017)

  • A.M. Palanca-Capistrano, J. Hall, L.B. Cantor, L. Morgan, J. Hoop, D. Wudunn, Long-term outcomes of intraoperative 5-fluorouracil versus intraoperative Mitomycin C in primary trabeculectomy surgery. Ophthalmology 116(2), 185–190 (2009)

    Article  Google Scholar 

  • H.A. Quigley, A.T. Broman, The number of people with glaucoma worldwide in 2010 and 2020. British J. Ophthalmol. 90, 262–267 (2006)

    Article  Google Scholar 

  • I. Riva, G. Roberti, F. Oddone, A.G. Konstas, L. Quaranta, Ahmed glaucoma valve implant: surgical technique and complications. Clin. Ophthalmol. 11, 357–367 (2017)

    Article  Google Scholar 

  • R. Rosenquist, D. Epstein, S. Melamed, M. Johnson, W.M. Grant, Outflow resistance of enucleated human eyes at two different perfusion pressures and different extents of trabeculotomy. Curr. Eye Res. 8(12), 1233–1240 (1989)

    Article  Google Scholar 

  • L. R. Schneider, S. B. Hannush, Boston Keratoprosthesis type I: Surgical techniques. Keratoprostheses and Artificial Corneas, Berlin: Springer, 2015, pp. 77–80

  • R. Suzuki, C. Dickens, A. Iwach, H. Hoskins, J. Hetherington, R. Juster, P. Wong, M. Klufas, C. Leong, N. Nguyen, Long-term follow-up of initially successful trabeculectomy with 5-fluorouracil injections. Ophthalmology 109(10), 1921–1924 (2002)

    Article  Google Scholar 

  • C. Toris, M. Yablonski, Y. Wang, C. Camras, Aqueous humor dynamics in the aging human eye. Am J. Ophthalmol. 127(4), 407–412 (1999)

    Article  Google Scholar 

  • C. Vass, C. Hirn, E. Unger, W. Mayr, M. Georgopoulos, G. Rainer, S. Richter-Mueksch, Human aqueous humor viscosity in cataract, primary open angle glaucoma and pseudoexfoliation syndrome. Investig. Ophthalmol. Visual Sci. 45(13), 5030 (2004)

    Google Scholar 

Download references

Acknowledgements

This study was partially supported by the Center for Implantable Devices (CID) at Purdue University and a grant from Bionode LLC. The authors would also like to acknowledge the contributions of Jay Shah and Rachael Swenson for providing invaluable manuscript feedback, as well as the expertise of surgical technician Curtis Slaubaugh.

All applicable international, national, and/or institutional guidelines for the care and use of animals were followed. All procedures performed in studies involving animals were in accordance with the ethical standards of the institution or practice at which the studies were conducted (PACUC Protocol #1309000929).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Brett Collar.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Collar, B., Simón, G., Yuan, Q. et al. Semi-permanent transcorneal filter support and in vivo surgical implantation technique for open-angle glaucoma treatment. Biomed Microdevices 21, 92 (2019). https://doi.org/10.1007/s10544-019-0440-7

Download citation

  • Published:

  • DOI: https://doi.org/10.1007/s10544-019-0440-7

Keywords

Navigation