Abstract
Stable chronic functionality of intracortical probes is of utmost importance toward realizing clinical application of brain-machine interfaces. Sustained immune response from the brain tissue to the neural probes is one of the major challenges that hinder stable chronic functionality. There is a growing body of evidence in the literature that highly compliant neural probes with sub-cellular dimensions may significantly reduce the foreign-body response, thereby enhancing long term stability of intracortical recordings. Since the prevailing commercial probes are considerably larger than neurons and of high stiffness, new approaches are needed for developing miniature probes with high compliance. In this paper, we present design, fabrication, and in vitro evaluation of ultra-miniature (2.7 μm x 10 μm cross section), ultra-compliant (1.4 × 10-2 μN/μm in the axial direction, and 2.6 × 10-5 μN/μm and 1.8 × 10-6 μN/μm in the lateral directions) neural probes and associated probe-encasing biodissolvable delivery needles toward addressing the aforementioned challenges. The high compliance of the probes is obtained by micron-scale cross-section and meandered shape of the parylene-C insulated platinum wiring. Finite-element analysis is performed to compare the strains within the tissue during micromotion when using the ultra-compliant meandered probes with that when using stiff silicon probes. The standard batch microfabrication techniques are used for creating the probes. A dissolvable delivery needle that encases the probe facilitates failure-free insertion and precise placement of the ultra-compliant probes. Upon completion of implantation, the needle gradually dissolves, leaving behind the ultra-compliant neural probe. A spin-casting based micromolding approach is used for the fabrication of the needle. To demonstrate the versatility of the process, needles from different biodissolvable materials, as well as two-dimensional needle arrays with different geometries and dimensions, are fabricated. Further, needles incorporating anti-inflammatory drugs are created to show the co-delivery potential of the needles. An automated insertion device is developed for repeatable and precise implantation of needle-encased probes into brain tissue. Insertion of the needles without mechanical failure, and their subsequent dissolution are demonstrated. It is concluded that ultra-miniature, ultra-compliant probes and associated biodissolvable delivery needles can be successfully fabricated, and the use of the ultra-compliant meandered probes results in drastic reduction in strains imposed in the tissue as compared to stiff probes, thereby showing promise toward chronic applications.
Similar content being viewed by others
References
J. Agorelius, F. Tsanakalis, A. Firgber, P.T. Thorbergsson, L.M.E. Pettersson, J. Schouenborg, Front. Neurosci. 9, 331 (2015)
N.A. Alba, Z. Du, K. Catt, T.D.Y. Kozai, X.T. Cui, Biosensors 5(4), 618–646 (2015)
J. Bartels, D. Andreasen, P. Ehirim, H. Mao, S. Seibert, E.J. Wright, P. Kennedy, J. Neurosci. Meth. 174(2), 168–176 (2008)
B. Bediz, E. Korkmaz, R. Khilwani, C. Donahue, G. Erdos, L.D. Falo Jr., O.B. Ozdoganlar, Pharm. Res. 31(1), 117–135 (2014)
R. Biran, D.C. Martin, P.A. Tresco, Exp. Neurol. 195(1), 115–126 (2005)
C.S. Bjornsson, S.J. Oh, Y.A. Al-Kofahi, Y.J. Lim, J.N. Turner, S. De, B. Roysam, W. Shain, S.J. Kim, J. Neural Eng. 3(3), 196–207 (2006)
E.N. Brown, L.M. Frank, D. Tang, M.C. Quirk, M.A. Wilson, J. Neurosci. 18(18), 7411–7425 (1998)
J.R. Capadona, K. Shanmuganathan, D.J. Tyler, S.J. Rowan, C. Weder, Science 319(5868), 1370–1374 (2008)
F. Casanova, P.R. Carney, M. Sarntinoranont, J. Neurosci. Methods 237, 79–89 (2014)
H.Y. Chan, Aslan, D. M. Aslam, S.H. Wang, G.M. Swain, K.D. Wise, MEMS 2008 – IEEE 21st International Conference on Micro Electro Mechanical Systems, 244–247(2008)
H.Y. Chan, M. Varney, S. Hatch, D. M. Aslam, TRANSDUCERS 2009 - 2009 International Solid-State Sensors, Actuators and Microsystems Conference. IEEE, 1202-1205 (2009)
H.Y. Chan, D.M. Aslam, J.A. Wiler, B. Casey, J. Microelectromech. Syst. 18(3), 511–521 (2009b)
Z.J. Chen, G.T. Gillies, W.C. Broaddus, S.S. Prabhu, H. Fillmore, R.M. Mitchell, F.D. Corwin, P.P. Fatouros, J. Neurosurg. 101(2), 314–322 (2004)
C.H. Chen, S.C. Chuang, H.C. Su, W.L. Hsu, T.R. Yew, Y.C. Chang, S.R. Yeh, D.J. Yao, Lab Chip 11(9), 1647–1655 (2011)
K.C. Cheung, K. Djupsund, Y. Dan, L.P. Lee, J. Microelectromech. Syst. 12(2), 179–184 (2003)
K.L. Drake, K.D. Wise, J. Farraye, D.J. Anderson, S.L. BeMent, IEEE Trans. Biomed. Eng. 35(9), 719–732 (1988)
I.D. Dryg, M.P. Ward, K.Y. Qing, H. Mei, J.E. Schaffer, P.P. Irazoqui, IEEE Trans. Neural Syst. Rehabil. Eng. 23(4), 562–571 (2015)
T. Escamilla-Mackert, N.B. Langhals, T.D.Y. Kozai, D.R. Kipke, Ann. Int. IEEE EMBS Conf. 1616-1618 (2009)
W. Fan, I. Maesoon, Y. Euisik, 2011 I.E. 16th International Conference on Solid-State Sensors, Actuators and Microsystems, 966–969 (2011)
G. K. Fedder, B. Ozdoganlar, P. J. Gilgunn, US Patent 9,241,651, (2016)
E.E. Fetz, D.V. Finocchio, Exp. Brain Res. 23(3), 217–240 (1975)
S. Filiz, C.M. Conley, M.B. Wasserman, O.B. Ozdoganlar, Int. J. Mach. Tools Manuf. 47(7), 1088–1100 (2007)
S. Filiz, L. Xie, L.E. Weiss, O.B. Ozdoganlar, Int. J. Mach. Tools Manuf. 48(3), 459–472 (2008)
C. P. Foley, K. B. Neeves, W. M. Saltzman, W. L. Olbricht, AIChE Annual Meeting (2006)
A.P. Georgopoulos, A.B. Schwartz, R.E. Kettner, Science 233(4771), 1416–1419 (1986)
P. J. Gilgunn, R. Khilwani, T. D. Y. Kozai, D. J. Weber, X. T. Cui, G. Erdos, O.B. Ozdoganlar, G.K. Fedder, 2012 I.E. 25th International Conference on Micro Electro Mechanical Systems (MEMS), 56-59 (2012)
A. Gilletti, J. Muthuswamy, J. Neural Eng. 3(3), 189–195 (2006)
M.D. Johnson, O.E. Kao, D.R. Kipke, J. Neurosci. Meth. 160(2), 276–287 (2007)
W.J. Kargo, D.A. Nitz, J. Neurosci. 23(35), 11255–11269 (2003)
L. Karumbaiah, S.E. Norman, N.B. Rajan, S. Anand, T. Saxena, M. Betancur, R. Patkar, R.V. Bellamkonda, Biomaterials 33(26), 5983–5996 (2012)
P. Kennedy, S.S. Mirra, R.A.E. Bakay, Neurosci. Lett. 142(1), 89–94 (1992)
D.H. Kim, D.C. Martin, Biomaterials 27(15), 3031–3037 (2006)
Y.T. Kim, R.W. Hitchcock, M.J. Bridge, P.A. Tresco, Biomaterials 25(12), 2229–2237 (2004)
C.L. Kolarcik, S.D. Leubben, S.A. Sapp, J. Hanner, N. Snyder, T.D.Y. Kozai, E. Chang, J.A. Nabity, S.T. Nabity, C.F. Lagenaur, X.T. Cui, Soft Matter 11(24), 4547–4861 (2015a)
C.L. Kolarcik, K. Catt, E. Rost, I.N. Albrecht, D. Bourbeau, Z. Du, T.D.Y. Kozai, X. Luo, D.J. Weber, X.T. Cui, J. Neural Eng. 12(1), 016008 (2015b)
E. Korkmaz, MS Dissertation, Bilkent University (2011), http://hdl.handle.net/11693/15171
E. Korkmaz, E.E. Friedrich, M.H. Ramadan, G. Erdos, A.R. Mathers, O.B. Ozdoganlar, N.R. Washburn, L.D. Falo, Acta Biomater. 24, 96–105 (2015a)
E. Korkmaz, E. E. Friedrich, M. H. Ramadan, G. Erdos, A. R. Mathers, O. B. Ozdoganlar, N. R. Washburn, L. D. Falo, Accept. J. Pharmaceut. Sci. (2015)
T.D.Y. Kozai, D.R. Kipke, J. Neurosci. Meth. 184(2), 199–205 (2009)
T.D.Y. Kozai, A.L. Vazquez, J. Mater. Chem. B 3, 4965–4978 (2015)
T.D.Y. Kozai, T.C. Marzullo, N.B. Langhals, F.M. Hooi, A.K. Majewska, E.B. Brown, D.R. Kipke, J. Neural Eng. 7(4), 046011 (2010)
T.D.Y. Kozai, A.L. Vazquez, C.L. Weaver, S.G. Kim, X.T. Cui, J. Neural Eng. 9(6), 066001 (2012a)
T.D.Y. Kozai, N.B. Langhals, P.R. Patel, X. Deng, H. Zhang, K.L. Smith, J. Lahann, N.A. Kotov, D.R. Kipke, Nat. Mater. 11(12), 1065–1073 (2012b)
T.D.Y. Kozai, N.A. Alba, H. Zhang, N.A. Kotov, R.A. Gaunt, X.T. Cui, in Nanotechnology and neuroscience: nano-electronic, photonic and mechanical neuronal interfacing, ed. by M.D. Vittorio, L. Martiradonna, J. Assad (Springer, New York, 2014a), pp. 71–134
T.D.Y. Kozai, X. Li, L.M. Bodily, E.M. Caparosa, G.A. Zenonos, D.L. Carlisle, R.M. Friedlander, X.T. Cui, Biomaterials 35(36), 9620–9634 (2014b)
T.D.Y. Kozai, Z. Gugel, X. Li, P.J. Gilgunn, R. Khilwani, O.B. Ozdoganlar, G.K. Fedder, D.J. Weber, X.T. Cui, Biomaterials 35(34), 9255–9268 (2014c)
T.D.Y. Kozai, Z. Du, Z.V. Gugel, M.A. Smith, S.M. Chase, L.M. Bodily, E.M. Caparosa, R.M. Friedlander, X.T. Cui, J. Neurosci. Meth. 242, 15–40 (2015a)
T.D.Y. Kozai, K. Catt, X. Li, Z.V. Gugel, V.T. Olafsson, A.L. Vazquez, X.T. Cui, Biomaterials 37, 25–39 (2015b)
T.D.Y. Kozai, A. Jaquins-Gerstl, A.L. Vazquez, A.C. Michael, X.T. Cui, ACS Chem. Neurosci. 6(1), 48–67 (2015c)
T.D.Y. Kozai, K. Catt, Z. Du, K. Na, O. Srivannavit, R.M. Haque, J. Seymour, K.D. Wise, E. Yoon, X.T. Cui, IEEE Trans. Biomed. Eng. 63(1), 111–119 (2016a)
T.D.Y. Kozai, A. Jaquins-Gerstl, A.L. Vazquez, A.C. Michael, X.T. Cui, Biomaterials 87, 157–169 (2016b)
T.D.Y. Kozai, J.R. Eles, A.L. Vazquez, X.T. Cui, J. Neurosci. Meth. 258, 46–55 (2016c)
A. Lecomte, V. Castagnola, E. Descamps, L. Dahan, M.C. Blatché, T.M. Dinis, E. Leclerc, C. Egles, C. Bergaud, J. Micromech. Microeng. 25(12), 125003 (2015)
K.K. Lee, J.P. He, A. Singh, S. Massia, G. Ehteshami, B. Kim, G. Raupp, J. Micromech. Microeng. 14(1), 32–37 (2003)
H. Lee, R.V. Bellamkonda, W. Sun, M.E. Levenston, J. Neural Eng. 2(4), 81–89 (2005)
C.D. Lee, S.A. Hara, L. Yu, J.T.W. Kuo, B.J. Kim, T. Hoang, V. Pikov, E. Meng, J. Biomed. Mater. Res. Part B: Appl. Biomater. 104(2), 357–268 (2016)
D. Lewitus, K.L. Smith, W. Shain, J. Kohn, Acta Biomater. 7(6), 2483–2491 (2011)
G. Lind, C.E. Linsmeier, J. Thelin, J. Schouenborg, J. Neural Eng. 7(4), 046005 (2010)
X. Liu, D.B. McCreery, L.A. Bullara, W.F. Agnew, IEEE Trans. Neural Syst. Rehabil. Eng. 14(1), 91–100 (2006)
M.C. Lo, S. Wang, S. Singh, V.B. Damodaran, H.M. Kaplan, J. Kohn, D.I. Shreiber, J.D. Zahn, Biomed. Microdevices 17(2), 1–11 (2015)
X. Luo, C. Matranga, S. Tan, N. Alba, X.T. Cui, Biomaterials 32(26), 6316–6323 (2011)
N.T. Markwardt, J. Stokol, R.L.R. Ii, J. Neurosci. Methods 214(2), 119–125 (2013)
P.T. McCarthy, K.J. Otto, M.P. Rao, Biomed. Microdevices 13(3), 503–515 (2011a)
P.T. McCarthy, M.P. Rao, K.J. Otto, J. Neural Eng. 8(4), 046007 (2011b)
G.C. McConnell, H.D. Rees, A.I. Levey, C.A. Gutekunst, R.E. Gross, R.V. Bellamkonda, J. Neural Eng. 6(5), 056003 (2009)
D. McCreery, A. Lossinsky, V. Pikov, X. Liu, IEEE Trans. Biomed. Eng. 53(4), 726–737 (2006)
M.T.C. McCrudden, A.Z. Alkilani, C.M. McCrudden, E. McAlister, H.O. McCarthy, A.W. Woolfson, R.F. Donnelly, J. Control. Release 180, 71–78 (2014)
S. Metz, A. Bertsch, D. Bertrand, P. Renaud, Biosens. Bioelectron. 19(10), 1309–1318 (2004)
J.T. Neary, Y. Kang, K.A. Willoughby, E.F. Ellis, J. Neurosci. 23(6), 2348–2356 (2003)
J.K. Nguyen, D.J. Park, J.L. Skousen, A.E. Hess-Dunning, D.J. Tyler, S.J. Rowan, C. Weder, J.R. Capadona, J. Neural Eng. 11(5), 056014 (2014)
M.A. Nicolelis, D. Dimitrov, J.M. Carmena, R. Crist, G. Lehew, J.D. Kralik, S.P. Wise, Proc. Natl. Acad. Sci. U. S. A. 100(19), 11041–11046 (2003)
D. P. O’Brien, T. R. Nichols, M. G. Allen, MEMS 2001-14th IEEE Int. Conf. Micro Electro Mech. Syst. 216–219 (2001)
P. R. Patel, H. Zhang, M. Robbins, J. Nofar, S. Marshal, M. Kobylarek, T. D. Y. Kozai, N. A. Kotov, C. A. Chestek, J. Neural Eng. 13(6), 066002 (2016)
C. Pang, J.G. Cham, Z. Nenadic, S. Musallam, Y.C. Tai, J.W. Burdick, R.A. Andersen, Conf. Proc. IEEE Eng. Med. Biol. Soc. 7, 7114–7117 (2005)
P.R. Patel, K. Na, H. Zhang, T.D.Y. Kozai, N.A. Kotov, C.A. Chestek, J. Neural Eng. 12(4), 046009 (2015)
V.S. Polikov, P.A. Tresco, W.M. Reichert, J. Neurosci. Methods 148(1), 1–18 (2005)
P.J. Rousche, R.A. Normann, J. Neurosci. Methods 82(1), 1–15 (1998)
A.J. Sawyer, T.R. Kyriakides, J. Neural Eng. 10(1), 016013 (2013)
A.B. Schwartz, D.W. Moran, Eur. J. Neurosci. 12(6), 1851–1856 (2000)
A.B. Schwartz, X.T. Cui, D.J. Weber, D.W. Moran, Neuron 52(1), 205–220 (2006)
J.P. Seymour, D.R. Kipke, Biomaterials 28(25), 3594–3607 (2007)
J.P. Seymour, Y.M. Elkasabi, H.Y. Chen, J. Lahann, D.R. Kipke, Biomaterials 30(31), 6158–6167 (2009)
W. Shain, L. Spataro, J. Dilgen, K. Haverstick, S. Retterer, M. Isaacson, M. Stalzman, J.N. Turner, IEEE Trans. Neural. Syst. Rehabil. Eng. 11(2), 186–188 (2003)
W. Shen, L. Karumbaiah, X. Liu, T. Saxena, S. Chen, R. Patkar, R.V. Bellamkonda, M.G. Allen, Microsyst. Nanoeng. 1, 15010 (2015)
L. Spataro, J. Dilgen, S. Retterer, A.J. Spence, M. Isaacson, J.N. Turner, W. Shain, Exp. Neurol. 194(2), 289–300 (2005)
J. Subbaroyan, D.C. Martin, D.R. Kipke, J. Neural Eng. 2(4), 103–113 (2005)
S. Suner, M.R. Fellows, C. Vargas-Irwin, G.K. Nakata, J.P. Donoghue, IEEE Trans. Neural. Syst. Rehabil. Eng. 13(4), 524–541 (2005)
T. Suzuki, K. Mabuchi, S. Takeuchi, Int IEEE EMBS Conf Neural Eng, 154–156 (2003)
D.H. Szarowski, M.D. Andersen, S. Retterer, A.J. Spence, M. Isaacson, H.G. Craighead, J.N. Turner, W. Shain, Brain Res. 983(1), 23–35 (2003)
D.M. Taylor, S.I. Tillery, A.B. Schwartz, Science 296(5574), 1829–1832 (2002)
B.A. Wester, R.H. Lee, M.C. LaPlaca, J. Neural Eng. 6(2), 024002 (2009)
Z. Xiang, S.C. Yen, N. Xue, T. Sun, W.M. Tsang, S. Zhang, L.D. Liao, N.V. Thakor, C. Lee, J. Micromech. Microeng. 24(6), 065015 (2014)
H. Yoon, C.S. Smith, V.K. Varadan, J. Nanotechnol. Eng. Med. 2(3), 031001 (2011)
M. Zhang, J. Wu, L. Wang, K. Xiao, W. Wen, Lab Chip 10(9), 1199–1203 (2010)
Acknowledgments
The authors would like to thank Prof. Shawn Lister and Pratiti Mandal for assistance with Xradia UltraXRM-L200 for nano-CT images. This work was supported in part by the Defense Advanced Research Projects Agency (DARPA) Biological Technologies Office (BTO) Electrical Prescriptions (ElectRx) program under the auspices of Dr. Douglas J. Weber through the Space and Naval Warfare Systems Center (SPAWAR) – Pacific, Cooperative Agreement No. HR0011-15-2-0009 and Microsystems Technology Office (MTO) under the auspices of Dr. Jack Judy through the SPAWAR, Pacific Award No. N66001-11-1-4025. Any opinions, findings, and conclusions or recommendations expressed in this publication are those of the authors and do not necessarily reflect the views of SPAWAR or DARPA.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Khilwani, R., Gilgunn, P.J., Kozai, T.D.Y. et al. Ultra-miniature ultra-compliant neural probes with dissolvable delivery needles: design, fabrication and characterization. Biomed Microdevices 18, 97 (2016). https://doi.org/10.1007/s10544-016-0125-4
Published:
DOI: https://doi.org/10.1007/s10544-016-0125-4