Historical earthquakes in developing countries, particularly in South America, have caused devastating effects in essential buildings, such as hospitals. As a result, some structural retrofits and new designs of essential facilities in South American countries have concentrated on increasing the seismic design forces beyond what is normally required by building codes. This increased-strength approach can lead to quasi-elastic structural response during earthquakes with much larger induced floor accelerations than expected from code-designed structures. In critical structures, sub-par performance of critical non-structural elements, such as medical equipment in a hospital, due to high-induced floor accelerations can have consequences as devastating as structural failures. Passive seismic protection systems, such as seismic isolation, provide a practical means of controlling seismic demand and are now common in developed countries. However, the applications of protection systems have been far fewer in developing countries due to economic considerations and lack of technical expertise. This paper presents the experimental and numerical studies supporting the development of a novel low-cost sustainable protection system incorporating recycled automobile tires for isolating designated floors or rooms in essential buildings in developing countries. The main innovation of the proposed floor isolation system is the geometric arrangement of the rubber tires that allows isolation from both, horizontal and vertical floor accelerations. Horizontal and vertical cyclic testing conducted on tire specimens are first described followed by the development of a numerical model able to reproduce the experimental results. Finally, an existing case-study hospital in Ecuador is considered for evaluating numerically the seismic performance of the proposed floor isolation system.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19
Fig. 20
Fig. 21
Fig. 22
Fig. 23
Fig. 24
Fig. 25
Fig. 26
Fig. 27
Fig. 28
Fig. 29
Fig. 30
Fig. 31
Fig. 32
Fig. 33
Fig. 34

Similar content being viewed by others

References

  • ASA (2017) Operating room design Manual, American Society of Anesthesiologists, Park Ridge, IL, available online at: https://www.asahq.org/resources/resources-from-asa-committees/operating-room-design-manual. Accessed 7 July 2018

  • ASCE (2010) ASCE/SEI standard no 7-10: minimum design loads for buildings and other structures. American Society of Civil Engineers, Reston

    Google Scholar 

  • ASTM (2012) Standard practice for use of scrap tires in civil engineering applications, ASTM Standard D6270-08(2012). ASTM International, West Conshohocken

    Google Scholar 

  • Baranowski P, Bogusz P, Gotowicki P, Małachowski J (2012) Assessment of mechanical properties of off road vehicle tire: coupons testing and FE model development. Acta Mechanica et Automatica 6(2):17–22

    Google Scholar 

  • Constantinou MC, Whittaker AS, Kalpakidis Y, Fenz DM, Warn GP (2007) Performance of seismic isolation hardware under service and seismic loading, Technical Report MCEER-07-0012. Multidisciplinary Center for Earthquake Engineering Research, University at Buffalo, State University of New York, Buffalo, NY

  • Cruz MF (1991) Comportamiento de hospitales en Costa Rica durante los sismos de 1990. [S.l.]: Organización Panamericana de la Salud, Pan American Health Organization, Washington, D.C., USA (in Spanish)

  • CSI (2011) Structural analysis program, version 15.0.1. Computer and Structures Inc., Berkeley

    Google Scholar 

  • Cui S, Bruneau M, Kasalanati A (2010) Behavior of bidirectional spring unit in isolated floor systems. J Struct Eng Am Soc Civ Eng 136(8):944–952

    Article  Google Scholar 

  • Demetriades GF, Constantinou MC, Reinhorn AM (1992) Study of wire rope systems for seismic protection of equipment in buildings. Technical report: NCEER-92-0012, National Center for Earthquake Engineering Research, Buffalo, NY

  • Eberhard MO, Baldridge S, Marshall, Mooney JW, Rix GJ (2010) The MW7.0 Haiti earthquake of January 12, 2010: USGS/EERI Advance reconnaissance team report, Open-File Report 2010–1048, U.S. Department of the Interior, U.S. Geological Survey, Reston, Virginia, USA

  • FEMA (2009) Quantification of building seismic performance factors, FEMA P695 document. Federal Emergency Management Agency, Washington, DC, p 421

    Google Scholar 

  • Fernandez J, Yepes H (1998) The Bahia de Caráquez, Ecuador, Earthquake of August 4, 1998, EERI Special Earthquake Report, Earthquake Engineering Research Institute, Oakland, CA, p 4

  • GeoHazards International (2009) Reducing earthquake risk in hospitals from equipment, contents, architectural elements and building utility systems. GeoHazards International, New Delhi

    Google Scholar 

  • Hinrichs R, Jones L, Stanley EM, Kleiner M (2010) Report on the 2010 Chilean earthquake and tsunami response, Open-File Report 2011-1053, version 1.1, U.S. Department of the Interior, U.S. Geological Survey, Reston, Virginia, USA

  • Jennings PG (1968) Equivalent viscous damping for yielding structures. J Eng Mech Div Am Soc Civ Eng 94(1):131–166

    Google Scholar 

  • Kaneki M, Yasui Y, Okuda Y (1995) Simultaneous horizontal and vertical vibration tests of three-dimensional floor isolation system. J Technol Des Archit Inst Jpn 1:186–190

    Google Scholar 

  • Kasalanati A, Reinhorn A, Constantinou MC, Sanders D (1997) Experimental study of ball-in-cone isolation system. In: Building to last: proceedings of structures congress XV. American Society of Civil Engineers, pp 1191–1195

  • Kemeny ZA (1997) Ball-in-cone seismic isolation bearing. US patent 5599106, https://www.google.com/patents/US5599106. Accessed 7 July 2018

  • Lanning F, Haro AG, Liu MK, Monzón A, Monzón-Despang H, Schultz A, Tola A (2016) M7.8 Muisne, Ecuador Earthquake on April 16, 2016. Earthquake reconnaissance team report, Earthquake Engineering Research Institute, Oakland, CA, USA

  • LSTC (2011) LS-DYNA (version 5.1.1) [computer program]. Livermore Software Technology Corporation, Livermore

    Google Scholar 

  • Makris M, Constantinou MC (1992) Spring-viscous damper systems for combined seismic and vibration isolation. Earthq Eng Struct Dyn 21(8):649–664

    Article  Google Scholar 

  • Mokha A, Constantinou MC, Reinhorn A (1988) Teflon bearings in aseismic base isolation: experimental studies and mathematical modeling. Report NCEER-88-0038, University at Buffalo, State University of New York, Buffalo, NY

  • Mooney M (1940) A theory of large elastic deformation. J Appl Phys 11(9):582–592

    Article  Google Scholar 

  • Morales EM (2017) Sustainable and low cost room seismic isolation for essential care units of hospitals in developing countries. Ph.D. Dissertation, University at Buffalo State University of New York, Buffalo, NY, p 419

  • NEC-15 (2015) Norma Ecuatoriana de la Construcción, Ministerio de Desarrollo Urbano y Vivienda, MIDUVI, Quito, Ecuador (in Spanish)

  • PAHO (Pan American Health Organization) (2003) Protecting new health facilities from natural disasters: guidelines for the promotion of disaster mitigation in health facilities. Washington, DC. www.paho.org/disasters. Accessed 7 July 2018

  • Rivlin RS (1948) Large elastic deformations of isotropic materials. IV. Further developments of the general theory. Philos Trans R Soc Lond A Math Phys Sci 241(835):379–397

    Article  Google Scholar 

  • Rodríguez JA (1998) Evaluación de los daños del hospital Miguel H. Alcívar de la ciudad de Bahía de Caráquez, Ecuador durante el terremoto del 4 de agosto de 1998. Report of the Institute of Research and Development of Engineering of the Catholic University of Guayaquil, Ecuador, p 8 (in Spanish)

  • Takase N, Arima F, Tanaka H, Egasira H (1997) Development of three-dimensional floor-isolated system. Part I: dynamic characteristics of floor-isolated method by suspended structure. Summaries of technical papers of annual meeting architectural institute of Japan, B-2, pp 595–596 (in Japanese)

  • Tönük E, Ünlüsoy S (2001) Prediction of automobile tire corning force characteristics by finite element modeling and analysis. Comput Struct 79:1219–1232

    Article  Google Scholar 

  • Wen Y (1976) Method for random vibration of hysteretic systems. J Eng Mech Div ASCE 102(EM2):249–263

    Google Scholar 

Download references

Acknowledgements

The authors gratefully acknowledge the National Secretary for Higher Education, Science, Technology and Innovation of Ecuador (SENESCYT) for providing financial support to the first author of this paper. The technical staff members of the Armed Forces University of Ecuador (ESPE) are also acknowledged for conducting the cyclic tests on the tire components. Finally, the authors are thankful to Professor Timothy Sullivan from the University of Canterbury for his initial suggestions regarding this research program.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Andre Filiatrault.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Morales, E., Filiatrault, A. & Aref, A. Seismic floor isolation using recycled tires for essential buildings in developing countries. Bull Earthquake Eng 16, 6299–6333 (2018). https://doi.org/10.1007/s10518-018-0416-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10518-018-0416-7

Keywords

Navigation