Abstract
Tracheal respiratory sound analysis is a simple and non-invasive way to study the pathophysiology of the upper airway and has recently been used for acoustic estimation of respiratory flow and sleep apnea diagnosis. However in none of the previous studies was the respiratory flow–sound relationship studied in people with obstructive sleep apnea (OSA), nor during sleep. In this study, we recorded tracheal sound, respiratory flow, and head position from eight non-OSA and 10 OSA individuals during sleep and wakefulness. We compared the flow–sound relationship and variations in model parameters from wakefulness to sleep within and between the two groups. The results show that during both wakefulness and sleep, flow–sound relationship follows a power law but with different parameters. Furthermore, the variations in model parameters may be representative of the OSA pathology. The other objective of this study was to examine the accuracy of respiratory flow estimation algorithms during sleep: we investigated two approaches for calibrating the model parameters using the known data recorded during either wakefulness or sleep. The results show that the acoustical respiratory flow estimation parameters change from wakefulness to sleep. Therefore, if the model is calibrated using wakefulness data, although the estimated respiratory flow follows the relative variations of the real flow, the quantitative flow estimation error would be high during sleep. On the other hand, when the calibration parameters are extracted from tracheal sound and respiratory flow recordings during sleep, the respiratory flow estimation error is less than 10%.
References
American Academy of Sleep Medicine Task force, S. Quan, J. Gillin, M. Littner, and J. Shepard. Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research; the report of an American academy of sleep medicine task force. Sleep 22:667–689, 1999.
Azarbarzin, A., and Z. Moussavi. Automatic and unsupervised snore sound extraction from respiratory sound signals. IEEE Trans. Biomed. Eng. 58(5):1156–1162, 2011.
Beck, R., G. Rosenhouse, M. Mahagnah, R. Chow, D. Cugell, and N. Gavriely. Measurements and theory of normal tracheal breath sounds. Ann. Biomed. Eng. 33(10):1344–1351, 2005.
Bertram, C. Flow-induced oscillation of collapsed tubes and airway structures. Respir. Physiol. Neurobiol. 163(1–3):256–265, 2008.
Bliwise, D., R. Benkert, and R. Ingham. Factors associated with nightly variability in sleep-disordered breathing in elderly. Chest 100(4):973–976, 1991.
Brown, I., T. Bradley, E. Phillipson, N. Zamel, and V. Hoffstein. Pharyngeal compliance in snoring subjects with and without obstructive sleep apnea. Am. Rev. Respir. Dis. 132(2):211–215, 1985.
Clark, S., C. Wilson, M. Satoh, D. Pegelow, and J. Dempsey. Assessment of inspiratory flow limitation invasively and noninvasively during sleep. Am. J. Respir. Crit. Care Med. 158:713–722, 1998.
Davies, H., and J. Ffowcs-Williams. Aerodynamic sound generation in a pipe. J. Fluid Mech. 32(4):765–778, 1968.
Fiz, J., R. Jan, A. Homs, J. Izquierdo, M. Garca, and J. Morera. Detection of wheezing during maximal forced exhalation in patients with obstructed airways. Chest 122(1):186–191, 2002.
Gavriely, N., and D. Cugell. Airflow effects on amplitude and spectral content of normal breath sounds. J. Appl. Physiol. 80(1):5–13, 1996.
Golabbakhsh, M. Tracheal breath sound relationship with respiratory flow: modeling, the effect of age and airflow estimation. Master’s thesis, Electrical and Computer Engineering Department, University of Manitoba, 2004.
Harper, V., S. Kraman, H. Pasterkamp, and G. Wodicka. An acoustic model of the respiratory tract. IEEE Trans. Biomed. Eng. 48(5):543–550, 2001.
Harper, V., H. Pasterkamp, H. Kiyokawa, and G. Wodicka. Modeling and measurement of flow effects on tracheal sounds. IEEE Trans. Biomed. Eng. 50(1):1–10, 2003.
Hossain, I., and Z. Moussavi. Respiratory airflow estimation by acoustical means. In: Proceedings of the Second Joint EMBS/BMES Conference, Houston, TX, USA, 2002, pp. 1476–1477.
Jane, R., J. Sola-Soler, J. Fiz, and J. Morera. Automatic detection of snoring signals: validation with simple snorers and OSAS patients. In: IEEE-EMBS, Chicago, IL, 2000, pp. 3129–3131.
Kraman, S., H. Pasterkamp, M. Kompis, M. Takase, and G. Wodicka. Effects of breathing pathways on tracheal sound spectral features. Respir. Physiol. 111:295–300, 1998.
Lessard, C., and W. Wong. Correlation of constant flow rate with frequency spectrum of respiratory sounds when measured at the trachea. IEEE Trans. Biomed. Eng. 33:461–463, 1986.
Levendowski, D., N. Zack, S. Rao, K. Wong, M. Gendreau, J. Kranzler, T. Zavora, and P. Westbrook. Assessment of the test–retest reliability of laboratory polysomnography. Sleep Breath. 13:163–167, 2009.
Malhotra, A., Y. Huang, R. Fogel, G. Pillar, J. Edwards, R. Kikinis, S. Loring, and D. White. The male predisposition to pharyngeal collapse: importance of airway length. Am. J. Respir. Crit. Care Med. 166(10):1388–1395, 2002.
Montazeri, A., E. Giannouli, and Z. Moussavi. Assessment of obstructive sleep apnea and its severity during wakefulness. Ann. Biomed. Eng. 40(4):916–924, 2012.
Mussell, M., and Y. Miyamoto. Comparison of normal respiratory sounds recorded from the chest and trachea at various respiratory air flow levels. Front. Med. Biol. Eng. 4:73–85, 1992.
Nakano, H., M. Hayashi, E. Ohshima, N. Nishikata, and T. Shinohara. Validation of a new system of tracheal sound analysis for the diagnosis of sleep apnea–hypopnea syndrome. Sleep 27(5):951–957, 2004.
Oud, M., and E. Maarsingh. Spirometry and forced oscillometry assisted optimal frequency band determination for the computerized analysis of tracheal lung sounds in asthma. Physiol. Meas. 25(3):595–606, 2004.
Pasterkamp, H., S. Kraman, and G. Wodicka. Respiratory sounds, advances beyond the stethoscope. Am. J. Respir. Crit. Care Med. 156:974–987, 1997.
Pasterkamp, H., and I. Sanchez. Tracheal sounds in upper airway obstruction. Chest 102(3):963–965, 1992.
Que, C., C. Kolmaga, L. Durand, S. Kelly, and P. Macklem. Phonospirometry for noninvasive measurement of ventilation: methodology and preliminary results. J. Appl. Physiol. 93:1515–1526, 2002.
Sanchez, I., A. Avital, I. Wong, A. Tal, and H. Pasterkamp. Acoustic versus spirometric assessment of bronchial responsiveness to methacholine in children. Pediatr. Pulmonol. 15(1):28–35, 1993.
Sanchez, I., and H. Pasterkamp. Tracheal sound spectra depend on body height. Am. Rev. Respir. Dis. 148(4 Pt 1):1083–1087, 1993.
Sola-Soler, J., R. Jane, J. Fiz, and J. Morera. Variability of snore parameters in time and frequency domains in snoring subjects with and without obstructive sleep apnea. In: IEEE-EMBS, Shanghai, China, 2005, pp. 2583–2586.
Soufflet, G., G. Charbonneau, M. Polit, P. Attal, A. Denjean, P. Escourrou, and C. Gaultier. Interaction between tracheal sound and flow rate: a comparison of some different flow evaluations from lung sounds. IEEE Trans. Biomed. Eng. 37(4):384–391, 1990.
Staats, B., H. Bonekat, C. Harris, and K. Offord. Chest wall motion in sleep apnea. Am. Rev. Respir. Dis. 130:59–63, 1984.
Stauffer, J., C. Zwillich, R. Cadieux, E. Bixler, A. Kales, L. Varano, and D. White. Pharyngeal size and resistance in obstructive sleep apnea. Am. Rev. Respir. Dis. 136(3):623–627, 1987.
Suratt, P., R. McTier, and S. Wilhoit. Collapsibility of the nasopharyngeal airway in obstructive sleep apnea. Am. Rev. Respir. Dis. 132(5):967–971, 1985.
Tenhunen, M., E. Rauhala, E. Huupponen, A. Saastamoinen, A. Kulkas, and S. Himanen. High frequency components of tracheal sound are emphasized during prolonged flow limitation. Physiol. Meas. 30(5):467–478, 2009.
White, F. Fluid Mechanics. New York: McGraw-Hill, 1994.
Yadollahi, A., E. Giannouli, and Z. Moussavi. Sleep apnea monitoring and diagnosis based on pulse oximetery and tracheal sound signals. Med. Biol. Eng. Comput. 48(11):1087–1097, 2010.
Yadollahi, A., and Z. Moussavi. A robust method for estimating respiratory flow using tracheal sounds entropy. IEEE Trans. Biomed. Eng. 53(4):662–668, 2006.
Yadollahi, A., and Z. Moussavi. Acoustical flow estimation: review and validation. IEEE Eng. Med. Biol. Mag. 26(1):56–61, 2007.
Yadollahi, A., and Z. Moussavi. A novel approach for acoustical respiratory flow estimation without the need for individual calibration. IEEE Trans. Biomed. Eng. 58(6):1663–1667, 2011.
Yap, Y., and Z. Moussavi. Acoustic airflow estimation from tracheal sound power. In: Proceedings of the IEEE Canadian Conference on Electrical and Computer Engineering (CCECE), 2002, pp. 1073–1076.
Yonemaru, M., K. Kikuchi, M. Mori, A. Kawai, T. Abe, T. Kawashiro, T. Ishihara, and T. Yokoyama. Detection of tracheal stenosis by frequency analysis of tracheal sounds. J. Appl. Physiol. 75(2):605–612, 1993.
Younes, M. Contributions of upper airway mechanics and control mechanisms to severity of obstructive apnea. Am. J. Respir. Crit. Care Med. 168(6):645–658, 2003.
Acknowledgments
This study was supported by TeleCommunication Research Labs (TRLabs), Canada. The authors would like to acknowledge and thank the staff of Misericordia Hospital Sleep Disorders Clinic for their invaluable help and assistance in clinical data recording.
Author information
Authors and Affiliations
Corresponding author
Additional information
Associate Editor John H. Linehan oversaw the review of this article.
Rights and permissions
About this article
Cite this article
Yadollahi, A., Montazeri, A., Azarbarzin, A. et al. Respiratory Flow–Sound Relationship During Both Wakefulness and Sleep and Its Variation in Relation to Sleep Apnea. Ann Biomed Eng 41, 537–546 (2013). https://doi.org/10.1007/s10439-012-0692-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10439-012-0692-3