Abstract
The steps followed to study the micromechanics of wood adhesive bond planes using X-ray computed tomography (XCT) and digital volume correlation (DVC) are described. Iodine-tagged adhesive was formulated to provide X-ray contrast between the wood cell material and the adhesive. Specimens were tested in single-lap shear by tension loading and scanned in a step-loading procedure. DVC was applied to natural texture (such as pits, cell tips, and ray cell features), and the accuracy and precision of DVC for wood texture were characterized. XCT imagery was segmented, and the morphology of the adhesive was compared with the load transfer characteristics. Challenges to be addressed for performing in situ experiments with natural texture and DVC are discussed. The results show measurable effects of the microstructure (such as rays and resin canals) on strain distributions, but determining whether or not there is a significant link between adhesive morphology and bond performance requires further study.
Similar content being viewed by others
References
Baensch F (2015) Damage evolution in wood and layered wood composites monitored in situ by acoustic emission, digital image correlation and synchrotron based tomographic microscopy. Dissertation, ETH Zurich. https://doi.org/10.3929/ethz-a-010411928
Bay BK (2008) Methods and applications of digital volume correlation. J Strain Anal Eng Des 43:745–760
Bay BK, Smith TS, Fyhrie DP, Saad M (1999) Digital volume correlation: three-dimensional strain mapping using X-ray tomography. Exp Mech 39:217–226. https://doi.org/10.1007/BF02323555
Bornert M, Brémand F, Doumalin P, Dupré JC, Fazzini M, Grédiac M, Hild F, Mistou S, Molimard J, Orteu JJ, Robert L, Surrel Y, Vacher P, Wattrisse B (2009) Assessment of digital image correlation measurement errors: methodology and results. Exp Mech 49:353–370. https://doi.org/10.1007/s11340-008-9204-7
Brault R, Germaneau A, Dupré JC, Doumalin P, Mistou S, Fazzini M (2013) In-situ analysis of laminated composite materials by X-ray micro-computed tomography and digital volume correlation. Exp Mech 53:1143–1151. https://doi.org/10.1007/s11340-013-9730-9
Ching DJ (2018) Github repository. https://github.com/carterbox/wpart. Accessed 12 Sept 2018
Derome D, Griffa M, Koebel M, Carmeliet J (2011) Hysteretic swelling of wood at cellular scale probed by phase-contrast X-ray tomography. J Struct Biol 173:180–190. https://doi.org/10.1016/j.jsb.2010.08.011
Estrada JB, Franck C (2015) Intuitive interface for the quantitative evaluation of speckle patterns for use in digital image and volume correlation techniques. J Appl Mech 82:095001. https://doi.org/10.1115/1.4030821
Forsberg F, Mooser R, Arnold M, Hack E, Wyss P (2008) 3D micro-scale deformations of wood in bending: synchrotron radiation µCT data analyzed with digital volume correlation. J Struct Biol 164:255–262
Forsberg F, Sjödahl M, Mooser R, Hack E, Wyss P (2010) Full three-dimensional strain measurements on wood exposed to three-point bending: analysis by use of digital volume correlation applied to synchrotron radiation micro-computed tomography image data. Strain 46:47–60. https://doi.org/10.1111/j.1475-1305.2009.00687.x
Gillard F, Boardman R, Mavrogordato M, Hollis D, Sinclair I, Pierron F, Browne M (2014) The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression. J Mech Behav Biomed Mater 29:480–499. https://doi.org/10.1016/j.jmbbm.2013.09.014
Gürsoy D, De Carlo F, Xiao X, Jacobsen C (2014) TomoPy: a framework for the analysis of synchrotron tomographic data. J Synchrotron Radiat 21:1188–1193
Kamke FA, Nairn JA, Muszynski L, Paris JL, Schwarzkopf M, Xiao X (2014) Methodology for micromechanical analysis of wood adhesive bonds using X-ray computed tomography and numerical modeling. Wood Fiber Sci 46:15–28
Leclerc H, Périé JN, Roux S, Hild F (2011) Voxel-scale digital volume correlation. Exp Mech 51:479–490. https://doi.org/10.1007/s11340-010-9407-6
McKinley PE (2016) Multi-scale investigation of adhesive bond durability. MS thesis, Oregon State University
McKinley P, Ching D, Kamke F, Zauner M, Xiao X (2016) Micro X-ray computed tomography of adhesive bonds in wood. Wood Fiber Sci 48:2–16
McKinley P, Kamke FA, Sinha A (2018) Analysis of adhesive penetration into wood using nano-X-ray computed tomography. Wood Fiber Sci 50(1):66–76
Nairn J (2014) NairnFEA. http://osupdocs.forestry.oregonstate.edu/index.php/NairnFEA. Accessed 27 June 2018
Palanca M, Tozzi G, Cristofolini L, Viceconti M, Dall’Ara E (2015) Three-dimensional local measurements of bone strain and displacement: comparison of three digital volume correlation approaches. J Biomech Eng 137:071006. https://doi.org/10.1115/1.4030174
Pan B (2013) Bias error reduction of digital image correlation using Gaussian pre-filtering. Opt Lasers Eng 51:1161–1167. https://doi.org/10.1016/j.optlaseng.2013.04.009
Paris JL, Kamke FA, Mbachu R, Kraushaar S (2014) Phenol formaldehyde adhesives formulated for advanced X-ray imaging in wood-composite bondlines. J Mater Sci 49:580–591. https://doi.org/10.1007/s10853-013-7738-2
Paris JL, Kamke FA, Xiao X (2015) X-ray computed tomography of wood-adhesive bondlines: attenuation and phase-contrast effects. Wood Sci Technol 49:1185–1208. https://doi.org/10.1007/s00226-015-0750-8
Reu PL (2013) Uncertainty quantification for 3D digital image correlation in imaging methods for novel materials and challenging applications. In: Proceedings of the 2012 annual conference on experimental and applied mechanics, vol 3, chapter 43, pp 311–317. https://doi.org/10.1007/978-1-4614-4235-6_43
Reu PL, Sutton M, Wang Y, Miller TJ (2009) Uncertainty quantification for digital image correlation in SEM annual conference, Albuquerque, New Mexico, USA, pp 311–317
Schwarzkopf M, Muszyński L (2015) Stereomicroscopic optical method for the assessment of load transfer patterns across the wood-adhesive bond interphase. Holzforschung 69:653–660. https://doi.org/10.1515/hf-2014-0098
Smith TS, Bay BK, Rashid MM (2002) Digital volume correlation including rotational degrees of freedom during minimization. Exp Mech 42:272–278
Tozzi G, Dall’Ara E, Palanca M, Curto M, Innocente F, Cristofolini L (2017) Strain uncertainties from two digital volume correlation approaches in prophylactically augmented vertebrae: local analysis on bone and cement-bone microstructures. J Mech Behav Biomed Mater 67:117–126. https://doi.org/10.1016/j.jmbbm.2016.12.006
Tran H, Doumalin P, Delisee C, Dupre JC, Malvestio J, Germaneau A (2013) 3D mechanical analysis of low-density wood-based fiberboards by X-ray microcomputed tomography and digital volume correlation. J Mater Sci 48:3198–3212. https://doi.org/10.1007/s10853-012-7100-0
Zauner M, Niemz P (2014) Uniaxial compression of rotationally symmetric Norway spruce samples: surface deformation and size effect. Wood Sci Technol 48:1019–1032. https://doi.org/10.1007/s00226-014-0658-8
Zauner M, Keunecke D, Mokso R, Stampanoni M, Niemz P (2012) Synchrotron-based tomographic microscopy (SbTM) of wood: development of a testing device and observation of plastic deformation of uniaxially compressed Norway spruce samples. Holzforschung 66:973–979. https://doi.org/10.1515/hf-2011-0192
Acknowledgements
This material is based upon work that is supported by the National Institute of Food and Agriculture, U.S. Department of Agriculture, under award number OREZ-WSE-589-U. This research used resources of the Advanced Photon Source, a U.S. Department of Energy (DOE) Office of Science User Facility operated for the DOE Office of Science by Argonne National Laboratory under Contract No. DE-AC02-06CH11357.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Ching, D.J., Kamke, F.A. & Bay, B.K. Methodology for comparing wood adhesive bond load transfer using digital volume correlation. Wood Sci Technol 52, 1569–1587 (2018). https://doi.org/10.1007/s00226-018-1048-4
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00226-018-1048-4