Axial and Total-Body Bone Densitometry Using a Narrow-Angle Fan-Beam

  • Original Article
  • Published:
Osteoporosis International Aims and scope Submit manuscript

Abstract:

We assessed a new dual-energy bone densitometer, the PRODIGY, that uses a narrow-angle fan-beam (4.5°) oriented parallel to the longitudinal axis of the body (i.e., perpendicular to the usual orientation). High-resolution scans across the body can be stepped at 17 mm intervals. The energy-sensitive array detector uses cadmium zinc telluride, which allowed rapid photon counting. Spine and femur scans required 30 s, and total-body scans required 4–5 min; the dose was only 3.7 mrem and 0.04 mrem respectively, or about 5 to 10 times lower than conventional fan-beam densitometry. We found only a small influence of soft-tissue thickness on bone mineral density (BMD) results. There was also a small ( ± 1%) influence of height above the tabletop on BMD results. A software correction for object height allowed a first-order correction for the large magnification effects of position on bone mineral content (BMC) and area. Consequently, the results for BMC and area, as well as BMD, with PRODIGY corresponded closely to those obtained using the predecessor DPX densitometer, both in vitro and in vivo; there was a generally high correlation (r= 0.98–0.99) for BMD values. Spine and femur values for BMC, area and BMD averaged within 0.5% in vivo (n= 122), as did total-body BMC and BMD (n= 46). PRODIGY values for total-body lean tissue and fat also corresponded within 1% to DPX values. Regional and total-body BMD were measured with 0.5% precision in vitro and 1% precision in vivo. The new PRODIGY densitometer appears to combine the low dose and high accuracy of pencil-beam densitometry with the speed of fan-beam densitometers.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 2 April 1999 / Accepted: 27 July 1999

Rights and permissions

Reprints and permissions

About this article

Cite this article

Mazess, R., Hanson, J., Payne, R. et al. Axial and Total-Body Bone Densitometry Using a Narrow-Angle Fan-Beam . Osteoporos Int 11, 158–166 (2000). https://doi.org/10.1007/PL00004178

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/PL00004178

Navigation