Skip to main content
Log in

A study of calcium ion-selective PVC membrane electrode based on neutral carrier N,n,n’,n’-tetracyclo-3-oxapetanediamide

  • Published:
Journal of Tongji Medical University Aims and scope Submit manuscript

Summary

A calcium ion-selective PVC membrane electrode based on neutral carrier n,n,n’,n’-tetracyclohexyl-3-oxapetanediamide, using di-(2-ethylhexyl) phthalate as the plasticizer and potassium tetrakis (4-chlorophenyl) borate as the additive is reported in this paper. The ion selective membrane consists of 1 wt % of the Ca2+ selective ligand, 65 wt % of the plasticizer, 1 wt % of the additive and 33 wt % of poly (vinyl chloride) powder. The electrode has the linear response range of 2.0 × 10™7 —10™1 mol/L with the Nernstian slope of 28 mV/decade at 25 °C and the detection limit of 2.0 × 10™8 mol/L. The response time of the calcium ion-selective electrode is 4s as the concentration of calcium ion is rapidly shifted from 10™5 to 10™4 mol/L. The potential stability and reproducibility are good. The free calcium in blood serum was determined by the calcium ion-selective electrode with satisfactory results.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ross JW. Calcium-selective electrode based on a liquid ion exchanger. Science 1967;156:1387

    Google Scholar 

  2. Griffiths GH, et al. An investigation of the optimum composition of poly (vinyl chloride) matrix membranes used for calcium-selective electrodes. Analyst 1972;97:420

    Article  CAS  Google Scholar 

  3. Moody JG, et al. A calcium-sensitive electrode based on a liquid ion exchanger in a poly (vinyl chloride) matrix. Analyst 1970;95:910

    Article  CAS  Google Scholar 

  4. Ruzika J, et al. Selectrode-The universal ion-selective electrode, Part VI. The calcium (I) selectrode employing a new ion exchanger in a nonporous membrane and a solid state reference system. Anal Chim Acta 1973;67:155

    Article  Google Scholar 

  5. Jagner D, et al. The suitability of various calcium electrodes based on metal salts of di-(n-octylphenyl) phosphoric acid and some derivatives for the measurement of caclcium in sea water. Anal Chim Acta 1975;80:9

    Article  CAS  Google Scholar 

  6. Ammann D, et al. Improved calcium ion-selective electrode based on a neutral carrier. Anal Lett 1975;8:709

    CAS  Google Scholar 

  7. Ammann D, et al. Intracellular neutral carrier-based Ca2+ microelectrode with subnanomolar detection limit. Pflügers Arch 1987;409:223

    PubMed  CAS  Google Scholar 

  8. Wan JH. The characteristics and applications of calcium-selective membrane electrode based on neutral carrier. The Fourth National Meeting on Chemical Sensors. Chengdu, October, 1986

  9. Ma YL, Morad M. The improvement of characteristics of neutral carrier calcium selective microelectrode and instantaneous determination of extracellular photo-released calcium. Journal of Transduction Technology 1987;2:18

    Google Scholar 

  10. Wu HL, Yu RQ. The study of PVC membrane pH electrode. The optimum membrane composition of PVC membrane pH electrodes are selected by cross desigh approach. Chemical Sensors 1986; 6:39

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Yi-long, M., Xiao-hong, R., Shi-ming, Z. et al. A study of calcium ion-selective PVC membrane electrode based on neutral carrier N,n,n’,n’-tetracyclo-3-oxapetanediamide. Journal of Tongji Medical University 12, 98–102 (1992). https://doi.org/10.1007/BF02887789

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02887789

Key words

Navigation