Skip to main content
Log in

An X-band time domain electron paramagnetic resonance spectrometer

  • Instrumentation Techniques
  • Published:
Pramana Aims and scope Submit manuscript

Abstract

A computer-controlled X-band time domain electron paramagnetic resonance (EPR) spectrometer, with a time resolution of the order of 0.5μsec, has been constructed with many of the crucial microwave components designed and fabricated by the Microwave Engineering Group of TIFR. The spectrometer operates either in a microwave power pulsed mode for determination of spin-lattice relaxation times by the saturation recovery technique or in the kinetic mode for determination of the time dependence of EPR signal after laser excitation. It has an automatic frequency control, an automatic phase control and, most importantly, a field-frequency lock which ensures good stability of the EPR line positions enabling signal averaging for extended periods. The constructional details of the spectrometer and its performance in both the modes are described here by reporting results on certain typical systems.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  • Atkins P W, McLauchlan K A and Simpson A F 1970J. Phys. E3 547

    ADS  Google Scholar 

  • Ayscough P B and Price M C 1971J. Chem. Soc. B491

  • Ayscough P B, English T H and Tong D A 1976J. Phys. E9 31

    ADS  Google Scholar 

  • Basu S, McLauchlan K A and Sealy G R 1983J. Phys. E16 767

    ADS  Google Scholar 

  • Bowers K D and Mims W B 1957Phys. Rev. 115 285

    Article  ADS  Google Scholar 

  • Bowman M K 1975The electron spin-lattice relaxation of radiation produced trapped electrons and trapped hydrogen atoms in glassy matrices Ph.D. Thesis, Wayne State University

  • Davis C F, Strandberg M W P and Kyhl R L 1958Phys. Rev. 111 1268

    Article  ADS  Google Scholar 

  • Fessenden R W 1973J. Chem. Phys. 58 2489

    Article  ADS  Google Scholar 

  • Fessenden R W and Schuler R H 1963J. Chem. Phys. 39 2147

    Article  ADS  Google Scholar 

  • Fessenden R W, Hornak J P and Venkataraman B 1981J. Chem. Phys. 74 3694

    Article  ADS  Google Scholar 

  • Grampp G 1985Rev. Sci. Instrum. 56 2050

    Article  ADS  Google Scholar 

  • Hewlett-Packard Co. 1960 Application note 28-Drift measurements in high stability signals

  • Huisjen M and Hyde J S 1974Rev. Sci. Instrum. 45 669

    Article  ADS  Google Scholar 

  • Kevan L and Schwartz R N Ed. 1979Time domain electron spin resonance (New York: John Wiley)

    Google Scholar 

  • Lingam K V, Nair P G and Venkataraman B 1972Proc. Indian Acad. Sci. A76 207

    Google Scholar 

  • Mailer C, Johnson J D S and Robinson B H 1985Rev. Sci. Instrum. 56 1917

    Article  ADS  Google Scholar 

  • McLauchlan K A and Sealy G R 1984Mol. Phys. 52 873

    Article  Google Scholar 

  • McLauchlan K A and Stevens D G 1986Mol. Phys. 57 223

    Article  ADS  Google Scholar 

  • Percival P W and Hyde J S 1975Rev. Sci. Instrum. 46 1522

    Article  ADS  Google Scholar 

  • Poole C P 1967Electron spin resonance—A comprehensive treatise on experimental techniques (New York: Interscience) p. 199

    Google Scholar 

  • Reggia F and Spencer E 1957Proc. IRE 45 1510 Reprinted in Whicker L R (ed.) 1974Ferrite control components (London: Artech House Inc.) Vol. 2

    Article  Google Scholar 

  • Roger G, More C and Blanc C 1980J. Phys. E13 522

    ADS  Google Scholar 

  • Sarkar B K, Sitaram R V S and Kumar M C 1972Proceedings of Symposium in Electronics, Hyderabad, Dept. of Atomic Energy

  • Scott P and Jeffries C D 1962Phys. Rev. 127 32

    Article  ADS  Google Scholar 

  • Verma N C and Fessenden R W 1976J. Chem. Phys. 65 2139

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Das, R., Venkataraman, B., Bhagat, V.R. et al. An X-band time domain electron paramagnetic resonance spectrometer. Pramana - J. Phys. 27, 661–677 (1986). https://doi.org/10.1007/BF02845293

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02845293

Keywords

PACS Nos

Navigation