Abstract
The monitoring of arterial blood oxygen saturation in patients with compromised peripheral perfusion is often difficult, because conventional noninvasive techniques such as pulse oximetry (SpO2) can fail. Poor peripheral circulation commonly occurs after major surgery including cardiopulmonary bypass. The difficulties in these clinical situations might be overcome if the sensor were to monitor a better perfused central part of the body such as the oesophagus. A new oesophageal photoplethysmographic (PPG) probe and an isolated processing system have been developed to investigate the pulsatile signals of anaesthetised adult patients undergoing routine surgery. Measurements were made in the middle third of the oesophagus, 25 cm to 30 cm from the upper incisors. The AC PPG signals are sampled by a data acquisition system connected to a laptop computer. The signals recorded correspond to infrared and red AC PPGs from the middle third oesophagus and the finger. Preliminary results from 20 patients show that good quality AC PPG signals can be measured in the human oesophagus. The ratio of the oesophageal to finger AC PPG amplitudes was calculated for the infrared and red wavelengths for each patient. The mean (±standard deviation) of this ratio was 2.9±2.1 (n=19) for the infrared wavelength and 3.1±2.4 (n=16) for the red wavelength. The red and infrared wavelengths used are appropriate for pulse oximetry and this investigation indicates that the mid-oesophagus may be a suitable site for the reliable monitoring of SpO2 in patients with poor peripheral perfusion.
Article PDF
Similar content being viewed by others
References
Atlee, J.L., andBratanow, N. (1995): ‘Comparison of surface and esophageal oximetry in man,’Anesthesiol.,83, A455
Borum, S.E. (1997): ‘The successful use of transesophageal pulse oximetry in a patient in whom peripheral pulse oximetry was unobtainable,’Anesthesia Analgesia,85, pp. 514–516
Bowes, W.A., Corke, B.C., andHulka, J. (1989): ‘Pulse oximetry: review of the theory, accuracy and clinical applications,’Obstetrics Gynaecol.,74, (2), pp. 541–546
Clayton, D.G., Webb, R.K., Ralston, A.C., Duthie, D. andRunciman, W.B. (1991): ‘A comparison of the performance of 20 pulse oximeters under conditions of poor perfusion’,Anaesthesia,46, pp. 3–10
Freund, P.R., Overand, P.T., Cooper, J., Jacobson, L., Bosse, S., Walker, B., Posner, K.L. andCheney, F.W. (1991): ‘A prospective study of intraoperative pulse oximetry failure’,J. Clin. Monitoring,7, (3), pp. 253–258
Moller, J.T., Johannessen, N.W., Espersen, K., Ravlo, O., Pedersen, B.D., Jensen, P.F., Rasmussen, N.H., Rasmussen, L.S., Pedersen, T., Cooper, J.B., Gravenstein, J.S., Chraemmer-Jorgensen, B., Wiberg-Jorgensen, F., Djernes, M., Heslet, L., andJohnsen, S.H. (1993): ‘Randomized evaluation of pulse oximetry in 20,802 patients’,Anesthesiol.,78, pp. 436–444
Prielipp, R.C., Scuderi, P.E., Butterworth, J.F., Royster, R.L. andAtlee, J.L. (1996): ‘Comparison of transesophageal pulse oximetry (TEPO) with peripheral surface pulse oximetry in CABG patients’,Anesthesiol.,85, 3A
Reich, D.L., Timcenko, A., Bodian, C.A., Kraidin, J., Hofman, J., Deperio, M., Konstadt, S.N., Kurki, T., andEisenkraft, J.B. (1996): ‘Predictors of pulse oximetry data failure’,Anesthesiol.,84, pp. 859–864
Rosenberg, J. andPedersen, M.H. (1990): ‘Nasal pulse oximetry overestimates oxygen saturation’,Anaesthesia,45, pp. 1070–1071
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kyriacou, P.A., Moye, A.R., Gregg, A. et al. A system for investigating oesophageal photoplethysmographic signals in anaesthetised patients. Med. Biol. Eng. Comput. 37, 639–643 (1999). https://doi.org/10.1007/BF02513360
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02513360