Abstract
Several parameters of the cardiovascular system fluctuate spontaenously owing to the activity of the autonomic nervous system. In the study, the simultaneous very low frequency (VLF) fluctuations of the arterial blood pressure, the tissue blood content and the tissue blood volume pulse are investigated. The latter two parameters are derived from the baseline BL and the amplitude AM of the photoplethysmographic (PPG) signal, measured on the fingertips of 20 healthy male subjects: the changes in the PPG parameters AM and BV, defined by BV=const.-BL, are related to the change in the tissue blood volume pulse and the total tissue blood volume, respectively. The VLF fluctuations in BV and AM are directly correlated, those of AM preceding those of BV by 4–13 heart-beats. The VLF fluctuations in the systolic (SBP) and the diastolic (DBP) blood pressure are inversely correlated to those of AM and BV, those of AM preceding those of SBP and lagging behing those of DBP by about one heart-beat. For most subjects, the period P of the PPG pulse, which is equal to the cardiac cycle period, directly correlates with AM and BV and inversely correlates with DBP and SBP. On average, the fluctuations fluctuations in tissue blood volume, systolic blood volume pulse, diastolic and systolic blood pressure, and heart period, together with their interrelationship, can provide a better understanding of the autonomic nervous control of the peripheral circulation and a potential tool for the evaluation of its function.
Similar content being viewed by others
References
Akselrod, S., Gordon, D., Madwed, J. B., Snidman, N. C., Shannon, D. C., andCohen, R.J. (1985): ‘Hemodynamic regulation: investigation by spectral analysis’,Am. J. Physiol.,249, pp. H867-H875
Burton, A. C. (1939): ‘The range and variability of the blood flow in the human fingers and the vasomotor regulation by body temperature’,Am. J. Physiol.,127, pp. 437–453
Guyton, A. C. (1986): ‘Medical physiology’, (W. B. Saunders Co., Philadelphia) 17th edn., ch. 57
Madwed, J. B., Albrecht, P., Mark, R. G., andCohen, R. J. (1989): ‘Low frequency oscillations in arterial pressure and heart rate: a simple computer model’,Am. J. Physiol.,256, pp. H1573-H1579
Malliani, A., Pagani, M., Lombardi, F., andCerutti, S. (1991): ‘Cardiovascular neural regulation explored in the frequency domain’,Circulation,84, pp. 482–492
Mancia, G., Ferrari, A., Gregorini, L., Parati, G., Pomidossi, G., Bertinieri, G., Grassi, G., di Reinzo, M., Pedotti, A., andZanchetti, A. (1983): ‘Blood pressure and heart rate variabilities in normotensive and hypertensive human beings’,Circ. Res.,53, pp. 96–104
Moser, M., Lehofer, M., Sedminek, A., Lux, M., Zapotoczky, H., Kenner, T., andNoordergraaf, A. (1994): ‘Heart rate variability as a prognostic tool in cardiology’,Circulation,90, pp. 1078–1082
Nitzan, M., de Boer, H., Turivnenko, S., Babchenko, A., andSapoznikov, D. (1994): ‘Power spectrum analysis of the spontaneous fluctuations in the photoplethysmographic signal’,J. Basic Clin. Physiol. Pharmacol.,5, pp. 269–276
Nitzan, M., Turivnenko, S., Milston, A., Babchenko, A., andMahler, Y. (1996a): ‘Low frequency variability in the blood volume and in the blood volume pulse measured by photoplethysmography’,J. Biomed. Optics.,1, pp. 223–229
Nitzan, M., Babchenko, A., Milston, A., Turivnenko, S., Khanokh, B., andMahler, Y. (1996b): ‘Measurement of the variability of the skin blood volume using dynamic spectroscopy’,Appl. Surface Sci.,106, pp. 478–482
Nitzan, M., Babchenko, A., Khanokh, B., andLandau, D. (1998): ‘The variability of the photoplethysmographic signal—A potential method for the evaluation of the autonomic nervous system’,Physiol. Meas.,19, pp. 93–102
Pinna, G. D., Maestri, R., andMortara, A. (1996): ‘Estimation of arterial blood pressure variability by spectral analysis: comparison between Finapres and invasive measurements’,Physiol. Meas.,17, pp. 147–169
Pinna, G. D., Maestri, R., La Rovere, M. T., andMortara, A. (1997): ‘Diastolic-systolic lag in spontaneous arterial blood pressure oscillations in normal and pathological subjects’. Proc. CiC Conf. on Computers in Cardiology, Lund
Robbe, H. W. J., Mulder, L. J. M., Ruddel, H., Langewitz, W. A., Veldman, J. B. P. andMulder, G. (1987): ‘Assessment of baroreceptor reflex sensitivity by means of spectral analysis’,Hypertension,10, pp. 538–543
Shimada, S. G., andMarsh, D. J. (1979): ‘Oscillations in mean arterial blood pressure in conscious dogs’,Circ Res.,44, pp. 692–698
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Nitzan, M., Babchenko, A. & Khanokh, B. Verylow frequency variability in arterial blood pressure and blood volume pulse. Med. Biol. Eng. Comput. 37, 54–58 (1999). https://doi.org/10.1007/BF02513266
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02513266