The monitoring of the development of respiratory function in low-birth-weight or sick neonates is important in its overall treatment. The most direct approach to obtaining information on respiratory function is to monitor the activity of the diaphragmatic muscular system rather than measure the resultant change in lung volume or ventilator output, which cannot be guaranteed to be directly related to the neonate's own respiratory activity. The system was designed to assess the feasibility of monitoring respiratory activity in such neonates by measuring the diaphragmatic electromyograph. It is hoped that this system can be used to monitor the development of lung function and possibly, if reliability proves adequate, the synchronisation and control of ventilator assistance. To monitor the EMG, the dominant effect of the ECG was removed using a digital processor. Initial clinical measurements indicate that neonatal respiratory activity can be monitored by measuring the diaphragmatic EMG. Comparative measurements show the EMG method is faster in detecting the inspiratory phase of a breath. Measurements on ventilated neonates showed the presence of intermittent respiratory activity. It also is proposed that clinically relevant information may be deduced from the analysis of the morphology of the detected EMG waveform.
Article PDF
Similar content being viewed by others
References
Bloch, R. (1983): ‘Subtraction of the electro-cardiac signal from respiratory electromyogram’,J. Appl. Physiol.,55, pp. 619–623
Field, D., Milner, A. D., andHopkins, I. E. (1985): ‘Manipulation of ventilator settings to prevent active expiration against positive pressure inflation,”Arch. Disease Childhood,60, pp. 1036–1040
Fox, R. E., Kosch, C., Feldman, A., andStark, A. R. (1988): ‘Control of inspiratory duration in premature infants,’J. Appl. Phys.,64, pp. 2597–2604
Greenough, A. (1988): ‘The premature infant's respiratory response to mechanical ventilation,’Early Human Dev.,17, (1), pp. 1–5
Greenough, A., andMilner, A. D. (1992): ‘Respiratory support using patient triggered ventilation in the neonatal period,’Arch. Disease Childhood,67, pp. 69–71
Greenough, A., Mitchell, A., andHird, H. (1989): ‘Limitations of patient triggered ventilation in neonates,’Arch. Diseases Childhood,64, pp. 924–929
Greenough, A., andMorley, C. J. (1982): ‘Oesophageal pressure measurements in ventilated preterm infants,’Arch. Disease Childhood,57, pp. 851–855
Greenough, A. andPool, J. (1988): ‘Neonatal patient triggered ventilation,’Arch. Disease Childhood,63, pp. 394–397
Hill, D. W., Dolan, A. M. (1976): ‘Intensive care instrumentation’ (Academic Press, London)
Javaheri, S., Vinegar, A., Smith, J., andDonovan, E. (1987): ‘Use of a modified swan-ganz pacing catheter for measuring pdi and diaphragmatic Emg,’Pflugers Arch.,408, pp. 642–645
Jerome, E., Holliday, T. andHyers, M. (1990a): ‘The reduction of weaning time from mechanical ventilation using tidal volume and relaxation biofeedback,’Am. Rev. Resp. Disease,141, pp. 1214–1220
Jerome, E., Holliday, T. andHyers, M. (1990B): ‘The reduction of weaning time from mechanical ventilation using tidal volume and relaxation biofeedback,’Am. Rev. Resp. Disease,141, pp. 1214–1220
Lourenco, R. V., andMueller, E. P. (1967): ‘Quantification of electrical activity in the human diaphragm,’J. Applied Physiology,22, pp. 598–600
Mehta, A., Callen, K., Wright, B. M., andStacey, T. E. (1986): ‘Patient triggered ventilation in the new-born’,Lancet, pp. 17–19
Nagata, S., Arsenault, A. B., Gagnon, D., Smyth, G., andMathieu, P. A. (1990): ‘Emg power spectrum as a measure of muscular fatigue at different levels of contraction,’Med. Biol. Eng. Comput.,28, pp. 374–378
Obrien, M. J., Prechtl, H. F. R., andVan Eykern, L. A. (1977): ‘Respiratory muscle EMG in newborns: a non-intrusive method,’Early Human Dev.,1 (3), pp. 265–283
O'Brien, M. J., Van Eykern, L. A., andPrechtl, H. F. R. (1983): ‘Monitoring respiratory activity in infants—a non-intrusive diaphragm Emg technique,’ (Academic Press, London), pp. 132–177
O'Brien, M. J., Van Eykern, L. A., Oetomo, S. B., andVan Vught, H. A. J. (1987): ‘Transcutaneous respiratory electromyographic monitoring,’Crit. care med.,14 (4), pp. 294–299
Parekh, D. A. (1991): ‘A microcontroller based automated ECG analysis system.’ MSc Thesis, University of Kent at Canterbury.
Repko, K. D., Greene, J. G., andEnderle, J. D. (1989): ‘A comparison of oesophageal and chest electrodes in studying the diaphragmatic emg,’Biomed. Sci. Instrum.,25, pp. 89–91
Smith, G., Arsenault, A. B., Nagata, S., Gagnon, D., andMathieu, P. A. (1990): ‘Slope of the Emg/moment relationship as a measure of muscular fatigue: a validation study,’Med. Biol. Eng. Comput.,28, pp. 379–383
Tortora, G. J. andGrabowski, S. R. (1993): ‘Principles of anatomy and Physiology,’ (Harper Collins College Publishers, New York) 7th edn.
Wright, B. M., andCallan, K. (1980): ‘A new respiratory recording and monitoring system.’ Ambulatory Monitoring Proc. Int. Symp., Ghent, Belgium, pp. 329–334
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Pang, P.C.W., Pepper, M.G. & Ducker, D.A. Monitoring respiratory activity in neonates using diaphragmatic electromyograph. Med. Biol. Eng. Comput. 33, 385–390 (1995). https://doi.org/10.1007/BF02510520
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02510520