Recording and processing of fetal movements and sounds obtained with the Inpho inductive transducer

  • North Sea: Physiological Measurement
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

A recently developed transducer based on an inductive principle allows recording of fetal displacement signals on the maternal abdominal wall. The transducer is a relatively passive device, in contrast to commonly applied ultrasound transducers. This permits long-term observation of fetal movements and sounds. The bandwidth of the system is DC −200 Hz (±3dB), and signal-to-noise ratios of more than 96 dB have been measured in a laboratory setup, whereas in the practical situation a signal-to-noise ratio of 78 dB has been established. The transducer has been applied to study fetal respiratory sinus arrhythmia, which means that fetal breathing movements have to be extracted from the transducer's output. This proved possible by digital filtering of the displacement signal as detected by the transducer. The transducer has also been applied in a study where the signal-to-noise ratio of fetal heart sounds as a function of location of the fetus and position of the transducer on the maternal abdominal wall has been studied. It proved possible to adequately record fetal heart sounds for measurement of fetal heart rate. Also uterine activity could be recorded using the sensor's DC output.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Ansourian, M. N., Dripps, J. H., Beattie, G. J. andBoddy, K. (1989) Autoregressive spectral estimation of fetal breathing movement.IEEE Trans.,BME-36, 1076–1084.

    Google Scholar 

  • Boddy, K. andDawes, G. S. (1975) Fetal breathing.Br. Med. Bull.,31, 3–7.

    Google Scholar 

  • Colley, N., Talbert, D. G., Davies, W. L., Fayers, P., Abraham, N. andSouthall, D. P. (1986) The fetal phonogram—a measure of fetal activity.Lancet,1, 931.

    Article  Google Scholar 

  • Divon, M. Y. (1987) Microcomputer-assisted evaluation of foetal well-being. InMicrocomputers in medicine.Geisow, andBarret (Eds.), B. V. Elsevier Science Publishers.

  • Dornan, J. C., Ritchie, J. W. K. andRuff, S. (1984) The rate and regularity of breathing movements in the normal and growth retarded fetus.Br. J. Obstet. Gynaecol.,91, 31–36.

    Google Scholar 

  • Goovaerts, H. G., Rompelman, O. andvan Geijn, H. P. (1989) A transducer for detection of fetal breathing movements.IEEE Trans.,BME-36, 471–478.

    Google Scholar 

  • Goovaerts, H. G. (1989) Instrumentation for the quantitative assessment of fetal respiratory sinus arrhythmia. Ph.D. Thesis, Free University, Thesis Publishers, Amsterdam.

    Google Scholar 

  • Goovaerts, H. G., Cohen, D., Dripps, J. H., Rompelman, O. andJongsma, H. W. (1991) A comparative experimental study of fetal phono- and movement sensors from Amsterdam, Cambridge and EdinburghClin. Phys. & Physiol. Meas.,12, (1), 55–64.

    Article  Google Scholar 

  • Laros, R. K., Wong, W. S., Heilbron, D. C., Parer, J. T., Schider, S. M., Naylor, H. andButler, J. (1977) A comparison of methods for quantitating fetal heart rate variability.Am. J. Obstet. Gynecol.,128, 381.

    Google Scholar 

  • Manning, F. A., Platt, L. D. andSipos, L. (1980) Ante-partum fetal evaluation: development of fetal biophysical profile.Ibid.,136, 787.

    Google Scholar 

  • Rompelman, O., Snijders, J. B. I. M. andvan Spronsen, C. B. (1982) The measurement of heart rate variability spectra with the help of a personal computer.IEEE Trans.,BME-29, 503–510.

    Google Scholar 

  • Sadovsky, E., Laufer, N. andAllen, J. W. (1979) The incidence of different types of fetal movements during pregnancy.Br. J. Obstet. Gynaecol.,86, 10–14.

    Google Scholar 

  • Schwartz, R. S., Reeves, J. T., Sodal, I. E. andBarnes, F. S. (1980) Improved phonocardiogram system based on acoustic impedance matching.Am. J. Physiol.,238, (Heart Circ. Physiol.,7) H604-H609.

    Google Scholar 

  • Talbert, D. G., Lyn Davies, W., Johnson, F., Abraham, N. andSouthal, D. P. (1986) Wide bandwidth fetal phonography using a sensor matched to the compliance of the mother's abdominal wall.IEEE Trans.,BME-33, 175–181.

    Google Scholar 

  • Timor-Tritsch, I., Dierkel, L. J. Jr.,Hertz, R. H., Zador, I. andRosen, M. G. (1979) Human fetal respiratory movements: techniques for non-invasive monitoring with the use of a tocodynamometer.Biol. Neonate,36, 18–24.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Goovaerts, H.G., Wilmsen, A.A., Cortenraad, M.G.G. et al. Recording and processing of fetal movements and sounds obtained with the Inpho inductive transducer. Med. Biol. Eng. Comput. 29, NS20–NS26 (1991). https://doi.org/10.1007/BF02446098

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02446098

Keywords

Navigation