Noise characteristics of stainless-steel surface electrodes

  • Transducers and Electrodes
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

Bioelectric events measured with surface electrodes are subject to noise components which may be significant in comparison with low-level biological signals such as evoked neuroelectric potentials, and myoelectric potentials. In an effort to better understand noise arising from these electrodes, electrode and measurement system noise is modelled. The effect of electrode surface area on electrode impedance and noise is studied using circular stainless-steel electrodes of varying diameters. The main contributions of the work are the development of a model for stainless-steel electrode noise as a function of electrode area, and demonstrating that, for the band-width of interest to evoked neuroelectric and myoelectric signals (8–10 000 Hz), the primary noise components are thermal and amplifier current generated. The magnitudes of both of these depend on the electrode impedance magnitude. Electrode impedance is shown to be a power function of both electrode diameter and frequency, consistent with a capacitive electrode model.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Bergey, G. E., Squires, R. D. andSipple, W. C. (1971) Electrocardiogram recording with pasteless electrodes.IEEE Trans.,BME-18, 206–211.

    Google Scholar 

  • Flasterstein, A. H. (1966a) Voltage fluctuations of metal-electrolyte interfaces.Med. & Biol. Eng.,4, 583–588.

    Google Scholar 

  • Flasterstein, A. H. (1966b) A general analysis of voltage fluctuations of metal electrolyte interfaces.Ibid.,4, 589–594.

    Google Scholar 

  • Geddes, L. A. (1972)Electrodes and the measurement of bioelectric events. Wiley-Interscience, New York.

    Google Scholar 

  • Hary, D., Bekey, G. andAntouelli, D. (1987) Circuit models and simulation analysis of electromyographic signal sources-I: The impedance of EMG electrodes.IEEE Trans.,BME-34, 91–97.

    Google Scholar 

  • Kramer, G. S. (1983) Influence of electrode on bioelectric signal recording.J. Clin. Eng.,8, (3), 243–247.

    Google Scholar 

  • McKinley, C. A. andParker, P. A. (1991) A beamformer for the acquisition of evoked potentials.IEEE Trans.,BME-38, 379–382.

    Google Scholar 

  • Netzer, Y. (1981) The design of low-noise amplifiers.Proc. IEEE,69, 728–740.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Godin, D.T., Parker, P.A. & Scott, R.N. Noise characteristics of stainless-steel surface electrodes. Med. Biol. Eng. Comput. 29, 585–590 (1991). https://doi.org/10.1007/BF02446089

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02446089

Keywords

Navigation