Value of the spectral broadening index in continuous wave Doppler measurements

  • Computing and Data Processing
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

In an experimental study the value of the spectral broadening index (SBI) in continuous-wave (CW) Doppler measurements has been evaluated. The minimum SBI-value per heart beat (i.e. during systole) was calculated from intraoperatively obtained near-field and far-field Doppler spectra of the infrarenal aorta of 10 dogs. Near-field Doppler spectra show the same shape as far-field Doppler spectra but have a significantly different SBI. The minimum SBI of CW Doppler only contains useful information if the Doppler measurements are performed in the far field using a wide ultrasound beam (low emitting frequency). In that case the velocity profile in the blood vessel can be deduced from the SBI. The SBI depends strongly on the distance between the main axis of the ultrasound beam and the centre of the insonated blood vessel. A proper centring of the ultrasound beam corresponds with SBI-curves during the heart cycle which shown minimal spectral broadening. A real-time display of the SBI-curve on the spectrum analyser provides the means of securing optimal CW Doppler spectra by minimising the SBI-curve during acquisition.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Angelson, B. A. J. (1975) Transcutaneous measurement of aortic blood velocity by ultrasound. Thesis, Trondheim, Norway.

  • Ascer, E., Veith, F. J., Morin, L., White-Flores, S. A., Scher, L. A., Samson, R. H., Weiser, R. K., Rivers, S. andGupta, S. K. (1984) Quantitative assessment of outflow resistance in lower extremity arterial reconstructions.J. Surg. Res.,37, 8–15.

    Article  Google Scholar 

  • Bandyk, D., Zierler, R., Berni, G. andThiele, B. (1983) Pulsed Doppler velocity patterns produced by arterial anastomoses.Ultrasound Med. Biol.,9, 79–87.

    Article  Google Scholar 

  • Bandyk, D., Zierler, R. andThiele, B. (1984) Detection of technical error during arterial surgery by pulsed Doppler spectral analysis.Arch. Surg.,119, 421–428.

    Google Scholar 

  • Blackshear, W. M., Philips, D. J., Thiele, B. L., Hirsch, J. H., Chikos, P. M., Marinelli, D. S., Ward, K. J. andStrandness, D. E. (1979) Detection of pulsed Doppler spectrum analysis.Surgery,86, 698–706.

    Google Scholar 

  • Bowald, S., Ericksson, I. andFagerberg, S. (1978) Intraoperative angiography in arterial surgery.Acta Chir. Scan.,144, 463–469.

    Google Scholar 

  • Creekmore, S. P., Graham, M. M., Jahn, G. E., Targett, R. C. andMcIlroy, M. B. (1982) Comparison of methods of recording and analysis of Doppler blood velocity signals in normal subjects.Ultrasound Med. Biol.,8, 525–535.

    Article  Google Scholar 

  • Douville, Y., Johnston, K., Kassam, M., Zuech, P., Cobbold, R. andJares, A. (1983) Anin vitro model and its application for the study of carotid Doppler spectral broadening.,9, 347–356.

    Article  Google Scholar 

  • Evans, D. (1982) Some aspects of the relationship between instantaneous volumetric blood flow and continuous wave Doppler ultrasound recordings (I).,8, 605–609.

    Article  Google Scholar 

  • Feinberg, D. A., Crooks, L., Hoenninger, J., Arakawa, M. andWatts, J. (1984) Pulsatile bloodflow velocity in human arteries displayed by magnetic resonance imaging.Radiology,153, 117–180.

    Google Scholar 

  • Fung, Y. C. (1984)Biodynamics circulation. Springer Verlag, New York, USA.

    Google Scholar 

  • Giddens, D., Madon, R. andCassanova, R. (1976) Measurement of disordered flows distal to subtotal vascular stenoses in the thoracic aortas of dogs.Circul. Res.,39, 112–119.

    Google Scholar 

  • Gosling, G. (1978) Doppler ultrasound assessment of occlusive arterial disease.The Practitioner, April 1978.

  • Hoeks, A. P. G. (1982) On the development of a multi-gate pulsed Doppler system with serial data-processing. Thesis, Maastricht, The Netherlands.

  • Newhouse, V. L., Varner, L. W. andBendick, P. J. (1977) Geometrical spectrum broadening in ultrasonic Doppler systems.IEEE Trans.,BME-24, 478–480.

    Google Scholar 

  • Newhouse, V. L., Furgason, E. S., Johnson, G. F. andWolf, D. A. (1980) The dependence of ultrasound Doppler band width on beam geometry.IEEE Trans.,SU-27, 50–59.

    Google Scholar 

  • Randall, D. R., Shircliffe, A. C. andPlonk, G. W. (1982) Femoral artery cuff plethysmography in arterial occlusive disease.American Surgeon,28, 333–338.

    Google Scholar 

  • Roederer, G. O., Langlois, Y. andStrandness, D. E. (1984) Comprehensive noninvasive evaluation of extracranial cerebrovascular disease. InNoninvasive diagnosis of vascular disease. Hershey, F. B., Barnes, R. W. Butterworths, London, U.K., 177–216.

    Google Scholar 

  • Wells, P. N. T. (1977)Biomedical ultrasonics. Academic Press, London, UK, 26–30.

    Google Scholar 

  • Wien, K. D. andHarder, D. (1982) Characteristics of the pulsed ultrasound field.Brit. J. Cancer [Suppl],45, 59–63.

    Google Scholar 

  • Woodcock, J. (1979)Ultrasonics. (Medical Physics Handbooks 1). Adam Hilger Ltd, Bristol, UK.

    Google Scholar 

  • Zierler, R., Bandyk, D., Berni, G. andThiele, B. (1983) Intraoperative pulsed Doppler assessment of carotid endarterectomy.Ultrasound Med. Biol.,9, 65–71.

    Article  Google Scholar 

  • Zuech, P., Cobbold, R. S., Kassman, M. andJohnston, K. W. (1982) The application of CCD transversal filters for real time spectral analysis of Doppler ultrasound signals.,8, 57–69.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wijn, P.F.F., van der Sar, P., Gootzen, T.H.J.M. et al. Value of the spectral broadening index in continuous wave Doppler measurements. Med. Biol. Eng. Comput. 25, 377–385 (1987). https://doi.org/10.1007/BF02443357

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02443357

Keywords

Navigation