Skip to main content
Log in

Seven matched bolometers for millimeter wave observations

  • Published:
International Journal of Infrared and Millimeter Waves Aims and scope Submit manuscript

Abstract

We have fabricated a millimeter wave observation system using an array of bolometric detectors. The performance of the system depends largely on obtaining identical performance from each bolometer. We achieved a variance in the responsivity of less than 4% except for one of the seven elements. The bolometers had an electrical NEP of 1.3×10−16 W/√Hz under radiation background loading of 30pW. We used an AC bridge readout circuit to significantly improve the stability of the array and showed that observations can be done without a mechanical beam switch. The bolometer array is now in use on the Nobeyama 45-m telescope for 150GHz observations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. A. E. Lange, E. Kreysa, S. E. McBride, P. L. Richards, and E. E. Haller, “Improved Fabrication Techniques for Infrared Bolometers,”Int. J. of Infrared and Millimeter Waves 4, 689 (1983)

    Google Scholar 

  2. H. Matsuo, M. Akiba, S. Hayakawa, T. Matsumoto, H. Murakami, M. Noda, S. Sato, M. Inoue, R. Kawabe, M. Tanaka, N. Ukita, “Near-Millimeter Observations with the 45-m Telescope,”Publ. Astron. Soc. Japan 42, 459 (1990)

    Google Scholar 

  3. F. M. Rieke, A. E. Lange, J. W. Beeman, E. E. Haller, “An AC Bridge Readout for Bolometric Detectors,”IEEE Trans. Nucl. Sci. NS-36, No.1, 946 (1989)

    Google Scholar 

  4. T. Wilbanks, M. Devlin, A. E. Lange, S. Sato, J. W. Beeman, E. E. Haller, “Improved Low Frequency Stability of Bolometric Detectors,”IEEE Trans. Nucl. Sci. NS-37, No.2, 566 (1990)

    Google Scholar 

  5. J. C. Mather, “Bolometers: Ultimate sensitivity, Optimization, and Amplifier Coupling,”Appl. Opt. 23, 584 (1984)

    Google Scholar 

  6. E. E. Haller, “Physics and Design of Advanced Infrared Bolometers and Photoconductors,”Proc. CIRP3. Third Intl. Conference on Infrared Physics, W. Rüegsegger and F. K. Kneubühl eds., pp. 43–52 (1984)

  7. E. E. Haller, N. P. Palaio, M. Rodder, W. L. Hansen and E. Kreysa, “NTD Germanium: A Novel Material for Low Temperature Bolometers,”Proc. Fourth Intl. Conf. on Neutron Transmutation Doping of Semiconductor Materials, National Bureau of Standards, June 1–2, 1982, Gaithersburg, MD., R. D. Larrabee ed., Plenum Press, pp. 21–36 (1984)

    Google Scholar 

  8. J. Clarke, G. I. Hoffer, P. L. Richards, and N.-H. Yeh, “Superconductive Bolometers for Submillimeter Wavelengths,”J. Appl. Phys. 48, 4865 (1977)

    Google Scholar 

  9. H. Matsuo, N. Kuno, K. Nakajima, Y. Mizumoto, “Seven Element Bolometer Array for the 45-m telescope,” in prep.

Download references

Author information

Authors and Affiliations

Authors

Additional information

H. Matsuo thanks those who helped him work on bolometers during his stay in Berkeley, especially to T. Wilbanks, M. Devlin and C. Inman. The authors are also grateful to S. Sato and T. Watabe at Nagoya University for their advice on the AC bridge circuit. This work is partly supported by the Shimazdu Science Foundation.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kuno, N., Matsuo, H., Mizumoto, Y. et al. Seven matched bolometers for millimeter wave observations. Int J Infrared Milli Waves 14, 749–762 (1993). https://doi.org/10.1007/BF02084285

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02084285

Keywords

Navigation