A clinical evaluation of rapid automatic noninvasive blood pressure determination with the Ohmeda 2120 “return-to-flow” method

Journal of Clinical Monitoring Aims and scope Submit manuscript

Abstract

Most commercial noninvasive blood pressure devices use the oscillometric method for determination of blood pressure. The Ohmeda 2120 noninvasive blood pressure monitor uses the oscillometric technique, but it also includes a “Sys Stat” mode for rapid determination of systolic blood pressure up to ten times per minute. This Sys Stat mode uses the “return-to-flow” method, in which the pressure on an upper arm cuff decreases in small steps until a finger sensor detects the first pulse of blood. Data from 16 patients monitored with the Ohmeda 2120 unit and with an arterial cannula were analyzed. The line of regression was Sys Stat = 0.85 (arterial) + 9.49. The Ohmeda 2120 monitor tended to under-estimate the arterial pressure, particularly at higher pressures. Several factors could have contributed to this underestimation. Even so, the accuracy is sufficient for clinical use under most circumstances. More importantly, in an urgent situation, the Sys Stat mode can provide a reading of systolic blood pressure within seconds.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Ramsey M III. Non-invasive automatic determination of mean arterial pressure. Med Biol Eng Comput 1979;17:11–18

    Article  PubMed  Google Scholar 

  2. Yelderman M, Ream AK. Indirect measurement of mean blood pressure in the anesthetized patient. Anesthesiology 1979;50:253–256

    Article  PubMed  CAS  Google Scholar 

  3. Lee J, Koh D, Ong CN. Statistical evaluation of agreement between two methods for measuring a quantitative variable. Comput Biol Med 1989;19:61–70

    Article  PubMed  CAS  Google Scholar 

  4. Altman DG, Bland JM. Measurement in Medicine: The analysis of method comparison studies. The Statistician 1983;32:307–317

    Article  Google Scholar 

  5. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1(8476):307–310.

    PubMed  CAS  Google Scholar 

  6. Loubser PG. Comparison of intra-arterial and automated oscillometric blood pressure methods in postoperative hypertensive patients. Med Instrum 1986;20:255–259

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Supported by a grant from Ohmeda.

Presented in part as a poster presentation at the annual meeting of the American Society of Anesthesiologists, San Francisco, October 1988.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Block, F.E., Fletcher, M.V., Morris, T.J. et al. A clinical evaluation of rapid automatic noninvasive blood pressure determination with the Ohmeda 2120 “return-to-flow” method. J Clin Monitor Comput 7, 241–244 (1991). https://doi.org/10.1007/BF01619267

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01619267

Key words

Navigation