A microscope-based flow cytophotometer

  • Papers
  • Published:
The Histochemical Journal Aims and scope Submit manuscript

Summary

By means of a new flow chamber, a standard fluorescence microscope with Epi illumination and 100 W mercury arc excitation has been turned into a flow cytophotometer combining high resolution and sensitivity with simplicity of operation. In the flow chamber, cells are passed in a narrow stream through the microscope focus carried by a laminar flow of water running on the open surface of a cover glass which is coupled to the oil immersion microscope objective. Two spectral components of the fluorescence, for example, resulting from specific staining of two different cellular constituents with different dyes, can be measured simultaneously in separate channels so as to produce three-dimensional histograms. The scattered light of the cells is detected in dark field by a second microscope situated opposite the primary objective. Scattered light detection is integrating with regard to scattering angle from 0° to 90°. Hence, diffraction pattern effects are eliminated and the light scatter signal is approximately proportional to cell dry weight. The Epi illumination, which implies that excitation and fluorescence collection are parfocal, greatly simplifies instrument adjustment, which is further facilitated by the fact that the cell stream can be viewed at high magnification. Cell measuring time is about 3 μs which implies a measuring rate of 3×103 cells/s at 1% coincidence rate. Sensitivity is sufficient for measuring the DNA content of bacteria (that is, approximately 5×10−15 g/cell) with a coefficient of variance (CV) of about 6%. CV<1% is achieved for DNA histograms of mammalian cells. A 5 W argon laser as excitation source facilitates slit scan analysis and increases the sensitivity and measuring rate by one to two orders of magnitude.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  • Barlogie, G., Spitzer, G., Hart, J. S., Johnston, D. A., Büchner, T., Schumann, J. &Drewinko, B. (1976) DNA histogram analysis of human hemopoietic cells.Blood 48, 245–51.

    PubMed  Google Scholar 

  • Crissman, H. A. &Tobey, R. A. (1974) Cell cycle analysis in 20 minutes.Science 184, 1297–8

    PubMed  Google Scholar 

  • Göhde, W. (1973) Automation of cytofluorometry by use of the impulse microphotometer. InFluorescence Techniques in Cell Biology (edited byThäer, A. A. andSernetz, M.), pp. 79–88. Berlin: Springer-Verlag.

    Google Scholar 

  • Göhde, W., Schumann, J., Otto, F., Hacker, U., Zante, J., Hansen, P., Büchner, TH., Schwall, M. &Barranco, S. (1980) DNA measurements on sperm and blood cells of genetically normal and abnormal humans. InProceedings of the IVth International Symposium on Flow Cytometry (edited byLærum, O. D., Lindmo, T. andThorud, E.), pp. 273–276. Oslo: Universitetsforlaget Oslo.

    Google Scholar 

  • Lindmo, T. &Steen, H. B. (1979) Characteristics of a simple, high resolution flow cytometer based on a new flow configuration.Biophys. J. 28, 33–44.

    PubMed  Google Scholar 

  • Pinkel, D., Dean, P., Lake, S., Peters, D., Mendelsohn, M., Gray, J., Van Dilla, M. &Gledhill, B. (1979) Flow cytometry of mammalian sperm. Progress in DNA and morphology measurement.J. Histochem. Cytochem. 27, 353–8.

    PubMed  Google Scholar 

  • Steen, H. B. &Lindmo, T. (1979) Flow cytometry: a high resolution instrument for everyone.Science 204, 403–4.

    PubMed  Google Scholar 

  • Steen, H. B. (1980) Further developments of a microscope-based flow cytometer: light scatter detection and excitation intensity compensation.Cytometry 1, 26–31.

    PubMed  Google Scholar 

  • Steen, H. B. &Boye, E. (1980) Bacterial growth studied by flow cytometry.Cytometry 1, 32–6.

    PubMed  Google Scholar 

  • Steen, H. B. &Boye, E. (1981) Escherichia coli growth studied by dual parameter flow cytophotometry.J. Bacteriol. 145, 1091–4.

    PubMed  Google Scholar 

  • Steen, H. B., Boye, E., Skarstad, K., Bloom, B., Godal, T. &Mustafa, S. (1982) Applications of flow cytometry on bacteria: cell cycle kinetics, drug effects, and quantitation of antibody binding.Cytometry 2, 249–57.

    PubMed  Google Scholar 

  • Van Dilla, M. A., Gledhill, B. L., Lake, S., Dean, P. N., Gray, J. W., Kachel, V., Barlogie, B. &Göhde, W. (1977) Measurement of mammalian sperm deoxyribonucleic acid by flow cytometry. Problems and approaches.J. Histochem. Cytochem. 25, 763–73.

    PubMed  Google Scholar 

  • Weller, L. A. &Wheeless, L. L., Jr (1982) EMOSS: An epi-illumination microscope objective slit-scan flow system.Cytometry 3, 15–8.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Steen, H.B. A microscope-based flow cytophotometer. Histochem J 15, 147–160 (1983). https://doi.org/10.1007/BF01042283

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01042283

Keywords

Navigation