Summary
To assess the role of color Doppler echocardiography in the early postoperative evaluation of patients with a Blalock-Taussig shunt we examined 13 consecutive infants who underwent insertion of either a modified right (6 patients) or a modified left (7 patients) Blalock-Taussig shunt (age range 7 days to 6 months, mean age 8 weeks). Examination of the patients in a high parasternal right or left long axis was able to determine patency of the shunt in 12 patients. In the remaining patient, who did not show flow in the shunt, complete occlusion of the shunt was confirmed by angiography. From subcostal views we were able to demonstrate patency of the shunt in 75% of the infants and in all patients younger than 4 weeks of age. In our experience color Doppler echocardiography is a highly reliable method for early postoperative evaluation of infants with a Blalock-Taussig shunt.
Similar content being viewed by others
References
Di Benedetto G, Tiraboschi R, Vanini V, et al. (1981) Systemic-pulmonary artery shunt using PTFE prosthesis (Gore-Tex): early results and long-term follow-up on 105 consecutive cases.Thorac Cardiovasc Surg 29:143–147
Di Segni E, Bakst A, Chetboun I, et al. (1988) Subcostal cross-sectional echocardiographic imaging of patent ductus arteriosus.Pediatr Cardiol 9:25–28
Higgins CB, Silverman NH, Kersting-Sommerhoff BA, Schmidt K (1990)Congenital heart disease: echocardiography and magnetic resonance imaging. Raven Press, New York, pp 47–55, 235–247
Hofbeck M, Singer H (1991) Bedeutung der subxiphoidalen Echokardiographie in der Diagnostik kongenitaler Herzfehler.Paediatr Prax 43:37–50
Kay PH, Capuani A, Franks R, Lincoln C (1983) Experience with the modified Blalock-Taussig operation using polytet-rafluoroethylene (Impra) grafts.Br Heart J 49:359–363
Marino B, Ballerini L, Marcelletti C et al. (1984) Right oblique subxiphoid view for two-dimensional echocardiographic visualization of the right ventricle in congenital heart disease.Am J. Cardiol 54:1064–1068
Marx GR, Allen HD, Goldberg SJ (1986) Doppler echocardiographic estimation of systolic pulmonary artery pressure in patients with aortic-pulmonary shunts.J Am Coll Cardiol 7:880–885
McKay R, de Leval MR, Rees P, et al. (1980) Postoperative angiographic assessment of modified Blalock-Taussig shunts using expanded polytetrafluoroethylene (Gore-Tex).Ann Thorac Surg 30:137–145
Reeder GS, Currie PJ, Hagler DJ, Tajik AJ, Seward JB (1986) Use of doppler techniques (continuous-wave, pulsed-wave, and color flow imaging) in the noninvasive hemodynamic assessment of congenital heart disease.Mayo Clin Proc 61:725–744
Smallhorn JF, Huhta JC, Anderson RH, Macartney FJ (1982) Suprasternal cross-sectional echocardiography in assessment of patent ductus arteriosus.Br Heart J 48:321–330
Snider RA, Serwer GA (1990)Echocardiography in pediatric heart disease. Year Book Medical Publishers, Chicago, pp 36–46, 330–332
Stevenson JG, Kawabori I, Bailey WW (1983) Noninvasive evaluation of Blalock-Taussig shunts: determination of patency and differentiation from patent ductus arteriosus by doppler echocardiography.Am Heart J 106:1121–1132
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Hofbeck, M., Singer, H., Wild, F. et al. Color Doppler imaging of modified Blalock-Taussig shunts during infancy. Pediatr Cardiol 15, 163–166 (1994). https://doi.org/10.1007/BF00800669
Issue Date:
DOI: https://doi.org/10.1007/BF00800669