Skip to main content
Log in

Newin vitro fluorimetric microtitration assays for toxicological screening of drugs

  • Published:
Cell Biology and Toxicology Aims and scope Submit manuscript

Abstract

Flow cytometry has been widely used to quantify fluorescent probes in cell culture. However, FCM is not adapted to toxicological screenings due to the cost, the length and the poor reproducibility of this technique. Moreover, several multicenter studies have preferred microtitration methodologies for drug screening. A new fluorimetric technology has been designed that is sensitive and adapted to direct screening in 96-well microplates. This fluorimeter uses cold light technology (CLF) with chemical and physical modifications of the lighting system (Rat et al., 1995). CLF allows reading of UV, visible and near infrared fluorescence by increasing light energy (from 1000 to 2300 lumens) and reducing the calorific part of light (IR>900 nm, Joule effect). It induces a decrease in background and a 500- to 1000-fold improvement of detection limit of probes in comparison with classical fluorimeters and permits detection of pg/ml to fg/ml. CLF allows easy evaluation of cell injury induced by physical agents (UVA) or chemical toxins (CCl4). Four biological endpoints for cytotoxicity evaluation have been tested with several probes: proliferation (H33258); viability (fluorescent Neutral Red); cell-cell adhesion (calcein-AM); and mitochondrial metabolic effects (Rhodamine 123). Rh 123 assay appeared more sensitive than fluorimetric or photometric detection of Neutral Red assay. Cold light fluorimetry (CLF) permits direct detection of low concentrations of probes (pg/ml to fg/ml). CLF is shown to improve classical cytotoxicity assays and, owing to its adaptability to microtitration (in 6-, 12- or 96-well plates and in Petri dishes), it is thus a promising alternative to flow cytometry for drug cytotoxicity screening.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Abbreviations

CLF:

cold light fluorimetry

FCM:

flow cytometry

H33258:

Hoechst 33258

IR:

infrared

NIR:

near infrared

UV:

ultraviolet

MTT:

tetrazolium salt (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-2H tetrazolium bromide)

Rh123:

Rhodamine 123

References

  • Adams EG, Barden K, Badiner R, Ulrich R, Bhuyan BK. Evaluation of Rhodamine 123 as a fluorescent probe to assess mitochondrial damage due to cytotoxic drugs. Cell Tiss Kinet. 1984;17:670–8.

    Google Scholar 

  • Balls M, Clothier RH. Comments on the scientific validation and regulatory acceptance of in vitro toxicity tests. Toxic in Vitro. 1991;5:535–8.

    Google Scholar 

  • Balls M, Fentem JH. Basal cytotoxicity and target organ toxicity in risk assessment. ATLA. 1992;20:368–88.

    Google Scholar 

  • Blein O, Adolphe, M, Lakhdar B et al.. Correlation and validation of alternative methods to the Draize eye irritation test (OPAL project). Toxic in Vitro. 1991;5:555–7.

    Google Scholar 

  • Borenfreund E, Puerner JA. A simple quantitative procedure using monolayer cultures for cytotoxicity assays (HTD/NR-90). J Tiss Cult Methods. 1984;9:7–9.

    Google Scholar 

  • Borenfreund E, Babich H, Martinalguacil N. Rapid chemosensitivity assay with human normal and tumor cells in vitro. In Vitro Cell Dev Biol. 1990;26:1030–4.

    Google Scholar 

  • Braut-Boucher F, Pichon J, Rat P, Adolphe M, Aubery M, Font J. New fluorimetric microtitration assay for the quantification of cell-cell adherence. Anal Cell Pathol. 1994;6:285–6.

    Google Scholar 

  • Chen LB, Summerhayes IC, Johnson LV, Walsh ML, Bernal SD, Lampidis TI. Probing mitochondria in living cells with Rhodamine 123. Cold Spring Harbor Symp Quant Biol. 1981;46:141–55.

    Google Scholar 

  • Combrier, E, Metezeau P, Ronot X, Kiefergachelin H, Adolphe M. Comparative assessment of in vitro toxicity of xenobiotics using flow cytometry and spectrophotometry. Toxic in Vitro. 1990;4:751–5.

    Google Scholar 

  • Denizot F, Lang R. Rapid colorimetric assay for cell growth and survival. Modifications to the tetrazolium dye procedure giving improved sensitivity and reliability. J Immunol Methods. 1986;89:271–7.

    Google Scholar 

  • Essig-Marcello JS, Van Buskirk RG. A double in situ cytotoxicity assay using the fluorescent probes Neutral Red and BCECF-AM. In Vitro Toxic. 1990;3:219–27.

    Google Scholar 

  • Fautrel A, Chesne C, Guillouzo A et al. A multicentre study of acute in vitro cytotoxicity in rat liver cells. Toxic in Vitro. 1991;5:543–7.

    Google Scholar 

  • Haugland RP. In: Larrison KD, ed. Handbook of fluorescent probes and research chemicals. Eugene, OR: Molecular Probes; 1992:175–8.

    Google Scholar 

  • Holmberg B. On the permeability to lissamine green and other dyes in the course of cell injury and cell death. Exp Cell Res. 1960;22:406–14.

    Google Scholar 

  • Johnson LV, Walsh ML, Chen LB. Localization of mitochondria in living cells with Rhodamine 123. Proc Natl Acad Sci USA. 1980;77:990–4.

    Google Scholar 

  • Kull FC, Cuatrecasas P. Estimation of cell number by Neutral Red content: Applications for proliferative and survival assays. Appl Biochem Biotechnol. 1983;8:97–103.

    Google Scholar 

  • Melzig M, Dienwiebel U. Is the estimation of the activity of MTT-reduction suitable for determination of the basal cytotoxicity. Pharmazie. 1990;45:515–7.

    Google Scholar 

  • Mosman T. Rapid colorimetric assay for cellular growth and survival: application to proliferation and cytotoxicity assays. J Immunol Methods. 1983;65:55–63.

    Google Scholar 

  • Peloux AF, Federici C, Bichet N, Gouy D, Cano JP. Hepatocytes in primary culture: an alternative to LD 50 testing? Validation of a predictive model by multivariate analysis. ATLA. 1992;20:8–26.

    Google Scholar 

  • Plummer HK, Dillard CY, Murray SA. Hoechst 33342 for microfluorimetric measurement of adrenocortical tumor cell proliferation. In Vitro Cell Dev Biol. 1992;28:4–6.

    Google Scholar 

  • Rago R, Mitchen J, Wilding G. DNA fluorimetric assay in 96-well tissue culture plates using Hoechst 33258 after cell lysis by freezing in distilled water. Anal Biochem. 1990;191:31–7.

    Google Scholar 

  • Rao J, Otto WR. Fluorimetric DNA assay for cell growth estimation. Anal Biochem. 1992;207:186–95.

    Google Scholar 

  • Rahn CA, Bombick DW, Doolittle DJ. Assessment of mitochondrial membrane potential as an indicator of cytotoxicity. Fund Appl Toxicol. 1991;16:435–48.

    Google Scholar 

  • Rat P, Simoulin JP, Hildeilfinger JC, Warnet JM, Adolphe M. Cell injury and antidote evaluations with fluorimetric microtitration assays. Toxicol Lett. 1992;S1:238–9.

    Google Scholar 

  • Rat P. New microtitration fluorometric technology — applications to dermotoxicity. Nv Dermatol. 1993;12:471–7.

    Google Scholar 

  • Rat P, Christen MO, Thevenin MM, Warnet JM, Adolphe. Cold light fluorimetry: A new technology for cell culture. Application to the evaluation of anetholtrithione and other biothiols. Methods Enzymol. 1995;252: (in press).

  • Richards WL, Song MK, Krutzsch H, Evarts RP, Marsden E, Thorgeirsson SS. Measurements of cell proliferation in microculture using Hoechst 33342 for rapid semiautomated microfluorimetric determination of chromatin DNA. Exp Cell Res. 1985;159:235–46.

    Google Scholar 

  • Ronot X, Benel L, Adolphe M, Mounolou JC. Mitochondrial analysis in living cells: the use of rhodamine 123 and flow cytometry. Biol Cell. 1986;57:1–8.

    Google Scholar 

  • Vistica DT, Skehan P, Scudiero D, Monks A, Pittman A, Boyd MR. Tetrazolium-based assays for cellular viability — a critical examination of selected parameters affecting formazan production. Cancer Res. 1991;51:2515–20.

    Google Scholar 

  • Weston SA, Parish CR. New fluorescent dyes for lymphocytes migration studies. Analysis by flow cytometry and fluorescence microscopy. J Immunol Methods. 1990;133:87–95.

    Google Scholar 

  • Wu EY, Smith MT, Bellomo G, Dimonte D. Relationships between the mitochondrial transmembrane potential, ATP concentration and cytotoxicity in isolated rat hepatocytes. Arch Biochem Biophys. 1990;282:358–62.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Rat, P., Korwin-Zmijowska, C., Warnet, J.M. et al. Newin vitro fluorimetric microtitration assays for toxicological screening of drugs. Cell Biol Toxicol 10, 329–337 (1994). https://doi.org/10.1007/BF00755779

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00755779

Keywords

Navigation