Summary
A set-up for percutaneous electrical stimulation of the forearm extensor muscles and measurement of wrist extension force is described. The frequency-force relationship and pulse duration-force relationship are described together with an experimental protocol showing that brief electrical test stimulations do not produce fatigue. In another set of experiments carried out a few weeks later, the subjects performed handgrip contractions: protocol A at 25% of maximal voluntary contraction (MVC) continuously until exhaustion, protocol B at 25% MVC intermittent (contraction + relaxation = 10 + 2 s) until exhaustion, and protocol C at 25% MVC intermittent until half the time to exhaustion. In all experiments, brief electrical stimulations were used to test the degree of fatigue during and up to 24 h after the experiments. There were marked changes in the force during stimulation at 20 and 100 Hz and these changes did not correlate with the increase in intramuscular temperature. Low frequency fatigue persisted for at least 24 h after protocol A and 1 h after protocols B and C. The significance of this is discussed and it is suggested that low frequency fatigue could be used as a sensitive indicator of muscle dysfunction after low and medium intensity exercise.
Similar content being viewed by others
References
Bigland-Ritchie B, Cafarelli E, Vollestad NK (1986) Fatigue of submaximal static contractions. Acta Physiol Scand 128 [Suppl 556]:137–148
Björksten M, Jonsson B (1977) Endurance limit of force in longterm intermittent static contractions. Scand J Work Environ Health 3:23–27
Borg J, Grimby L, Hannerz J (1983) The fatigue of voluntary contractions and the peripheral electrical propagation of single motor units in man. J Physiol 340:435–444
Davies CTM, Mecrow IK, White MJ (1982) Contractile properties of the human triceps surae with some observations on the effects of temperature and exercise. Eur J Appl Physiol 49:255–269
Duchenne GB (1872) De l'Electrisation Localisée et de son Application a la Pathologie et a la Thérapeutique par Courants Induits et par Courants Galvaniques Interrompus et Continus. 3 iemme éd. Ballière, Paris
Duchateau J, Hainut K (1985) Electrical and mechanical failures during sustained and intermittent contractions in humans. J Appl Physiol 58:942–947
Edwards RHT, Hill DK, Jones DA, Merton PA (1977) Fatigue of long duration in human skeletal muscle after exercise. J Physiol 272:769–778
Hagberg M (1981) Muscular endurance and surface electromyogram in isometric and dynamic exercise. J Appl Physiol Respir Environ Exerc Physiol 51:1–7
Hicks A, Fenton J, Garner S, McComas AJ (1989) M-wave potentiation during and after muscle activity. J Appl Physiol 66:2606–2610
Hultman E, Sjöholm H, Jäderholm-Ek I, Krynicki J (1983) Evaluation of methods for electrical stimulation of human skeletal muscle in situ. Pflügers Arch 398:139–141
Johnson MA, Polgar J, Weightman D, Appleton D (1973) Data on the distribution of fibre types in thirty-six human muscles — an autopsy study. J Neurol Sci 18:111–129
Jones DA, Bigland-Ritchie B, Edwards RHT (1979) Excitation frequency and muscle fatigue: mechanical responses during voluntary and stimulated contractions. Exp Neurol 64:401–413
Klein C, Cunningham DA, Paterson DH, Taylor AW (1988) Fatigue and recovery properties of young and elderly men. Eur J Appl Physiol 57:684–690
Kroemer KHE (1989) Cumulative trauma disorders: their recognition and ergonomics measures to avoid them. Appl Ergon 20:274–280
Kroon GW, Naeije M (1988) Recovery following exhaustive dynamic exercise in the human biceps muscle. Eur J Appl Physiol 58:228–232
Kurppa K, Waris P, Rokkanen P (1979) Peritendinitis and tenosynovitis. A review. Scand J Work Environ Health 5 [Suppl 31]:19–24
Lindström LR (1970) Technical report. Chalmers University of Technology, Gothemburg, Sweden
Milerad E, Kilbom A (1985) Physiological and electromyographic response to repetitive handgrip exercise. Clin Physiol 5 [Suppl 4] p 134
Mortimer JT, Magnusson R, Petersen I (1970) Conduction velocity in ischemic muscle: effect on EMG frequency spectrum. Am J Physiol 219:1324–1329
Sandercock TG, Faulkner JA, Albers JW, Abbrecht PH (1985) Single motor unit and fiber action potentials during fatigue. J Appl Physiol 58:1073–1079
Sjöholm H, Sahlin K, Edström L, Hultman E (1983) Quantitative estimation of anaerobic and oxidative energy metabolism and contraction characteristics in intact human skeletal muscle in response to electrical stimulation. Clin Physiol 3:227–239
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Byström, S., Kilbom, Å. Electrical stimulation of human forearm extensor muscles as an indicator of handgrip fatigue and recovery. Europ. J. Appl. Physiol. 62, 363–368 (1991). https://doi.org/10.1007/BF00634974