Skip to main content
Log in

A new approach to positron emission tomography

  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

A recently developed detection principle for gamma rays offers the prospect of improving the performance of positron emission tomographic scanners. This detection principle is based on the use of BaF2 scintillator and photosensitive wire chambers. We present technical results obtained with a prototype detector. It is shown that the impact point of the gamma ray can be determined with a precision of a few mm and that the detection efficiency is 60% with a time resolution of 10 ns (FWHM). A scanner based on the new principle is described and its anticipated performance discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Arnold R, Baillon P, Berst JD, Besch HJ, Bosteels M, Christophel E, Giomataris Y, Guyonnet JL, Passardi G, Seguinot J, Tocqueville J, Toet D, Ypsilantis T (1986) Photosensitive gas detectors for ring-imaging Cherenkov (RICH) technique and the DELPHI barrel RICH Prototype. Nucl Instr Methods A 252:188–207

    Google Scholar 

  • Flower MA, Ott RJ, Webb S, Leach MO, Marsden PK, Clack R, Khan O, Batty V, McCready VR, Bateman JE (1988) Clinical trials of the prototype Rutherford Appleton Laboratory MWPC Positron Camera at the Royal Marsden Hospital. Nucl Instr Methods A 269:350–353

    Google Scholar 

  • Miné P, Charpak G, Santiard J-C, Scigocki D, Suffert M, Tavernier S (1988) Tests of a BaF2-TMAE detector for positron emission tomography. Nucl Instr Methods A 269:385–391

    Google Scholar 

  • Schotanus P (1987) A new gamma camera for positron emission tomography, Thesis. University of Delft, The Nederlands

    Google Scholar 

  • Townsend D, Frey P, Jeavons A, Reich G, Tochon-Danguy HJ, Donath A, Christin A, Schaller G (1987) The HIDAC Positron Camera. J Nucl Med 28:1554

    Google Scholar 

  • Townsend D, Spinks T, Jones T, Geissbühler A, Defrise M, Carla Gilardi M, Heather J (1989) Aspects of three dimensional reconstruction for a multi-ring positron tomograph. Eur J Nucl Med 15:741–745

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Charpak, G., Imrie, D., Jeanjean, J. et al. A new approach to positron emission tomography. Eur J Nucl Med 15, 690–693 (1989). https://doi.org/10.1007/BF00631758

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00631758

Key words

Navigation