Extracorporeal magnet perivascular electromagnetic flow meters

  • Instruments and Techniques
  • Published:
Pflügers Archiv Aims and scope Submit manuscript

Summary

The “interrupted resonance” circuit proved effective in combination with an extracorporeal magnet in permitting electromagnetic blood flow measurements to be made in branch arteries of dogs by application of perivascular cuffs equipped with pick-up electrodes contacting the vessel wall. A four-turn coil, acting as a transformer secondary measures the amplitude of the magnetic field component which is effective in inducing the flow signal and thus permits calibrations for arbitrary orientations of the perivascular cuff relative to the magnetic field of the extracorporeal magnet. Recordings of mean and phasic blood flow in dogs' arteries provide illustrations of effectiveness in pharmacological studies and exhibit the reliability of the non-occlusive zero-flow base line obtained by de-energizing the magnet.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Debley, V. G.: Miniature hydraulic occluder for zero blood determination. J. appl. Physiol.31, 138–139 (1971)

    Google Scholar 

  2. Gessner, U.: Effects of the vessel wall on electromagnetic flow measurement. Biophys. J.1, 627–637 (1961)

    Google Scholar 

  3. Gregg, D. E.: Physiology of the coronary circulation. Circulation27, 1128–1137 (1963)

    Google Scholar 

  4. Khouri, E. M., Gregg, D. E.: Miniature electromagnetic flow meter applicable to coronary arteries. J. appl. Physiol.18, 224 (1963)

    Google Scholar 

  5. Kolin, A.: An electromagnetic flow meter. Principle of the method and its application to blood flow measurements. Proc. Soc. exp. Biol. (N. Y.)35, 53–56 (1936)

    Google Scholar 

  6. Kolin, A.: An A. C. induction flow meter for measurement of blood flow in intact blood vessels. Proc. Soc. exp. Biol. (N. Y.)46, 235–239 (1941)

    Google Scholar 

  7. Kolin, A.: Improved apparatus and technique for electromagnetic determination of blood flow. Rev. Sci. Instr.23, 235–242 (1952)

    Google Scholar 

  8. Kolin, A.: Electromagnetic blood flow meters. Science130, 1088–1097 (1959)

    Google Scholar 

  9. Kolin, A.: Circulatory System: Blood flow determination by electromagnetic method. In: Medical physics, vol. 3 (O. Glasser, ed.), pp. 141–156. Chicago: Year Book Publ. Co. 1960

    Google Scholar 

  10. Kolin, A.: Evolution of electromagnetic blood flow meters. In: UCLA Forum in the Medical Sciences, vol. 10, pp. 383–405. Los Angeles: University of Calif. Press 1970

    Google Scholar 

  11. Kolin, A., Assali, N. S., Herrold, G., Jensen, R.: Electromagnetic determination of regional blood flow in unanesthetized animals. Proc. nat. Acad. Sci. (Wash.)43, 527–540 (1957)

    Google Scholar 

  12. Kolin, A., Austin, S., Cox, P.: Electromagnetic observations of carotid blood flow changes in the conscious rat in response to sensory stimuli. Nature (Lond.)201, 573–574 (1964)

    Google Scholar 

  13. Kolin, A., Grollman, J. H., Steckel, R. J., Snow, H. D.: Determination of arterial blood flow by percutaneously introduced flow sensors in an external magnetic field. II. Implementation of the method in vivo. Proc. nat. Acad. Sci. (Wash.)68, 29–33 (1971)

    Google Scholar 

  14. Kolin, A., Kado, R. T.: Miniaturization of the electromagnetic flow meter and its use for the recording of circulatory responses of conscious animals to sensory stimuli. Proc. nat. Acad. Sci. (Wash.)45, 1312–1321 (1959)

    Google Scholar 

  15. Kolin, A., Steele, J. R., Imai, J. S., MacAlpin, R. N.: A constant field interrupted resonance system for percutaneous electromagnetic measurement of blood flow. Proc. nat. Acad. Sci. (Wash.)71, 1294–1298 (1974)

    Google Scholar 

  16. Kolin, A., Weissberg, J. L., Gerber, L.: Electromagnetic measurement of blood flow and sphygmomanometry in the intact animal. Proc. Soc. exp. Biol. (N. Y.)47, 324–329 (1941)

    Google Scholar 

  17. Spencer, M. P., Denison, A. B.: The square-wave electromagnetic flowmeter: Theory of operation and design of magnetic probes for clinical and experimental applications. IRE Trans ME-6, 220–228 (1959)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kolin, A., Steele, J.R., Imai, J.S. et al. Extracorporeal magnet perivascular electromagnetic flow meters. Pflugers Arch. 362, 279–283 (1976). https://doi.org/10.1007/BF00581182

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00581182

Key words

Navigation