A method for the measurement of tremor, and a comparison of the effects of tocolytic Β-mimetics

  • Published:
European Journal of Applied Physiology and Occupational Physiology Aims and scope Submit manuscript

Summary

A method permitting measurement of finger tremor as a displacement-time curve is described, using a test system with simple amplitude calibration.

The coordinates of the inversion points of the displacement-time curves were transferred through graphical input equipment to punched tape. By means of a computer program, periods and amplitudes of tremor oscillations were calculated and classified. The event frequency for each class of periods and amplitudes was determined. The actions of fenoterol-hydrobromide, ritodrin-HCl and placebo given to 10 healthy subjects by intravenous infusion in a double-blind crossover study were tested by this method.

At therapeutic doses, both substances raised the mean tremor amplitude to about three times the control level. At the same time, the mean period within each class of amplitudes shortened by 10–20 ms, whereas the mean periods calculated from all oscillations together did not change significantly. After the end of fenoterol-hydrobromide infusion, tremor amplitudes decreased significantly faster than those following ritodrin-HCl infusion.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Finke, J., Bachhausen, D.: Tremorregistrierung mittels Infraton-Pulsabnehmer. Nervenarzt 46, 272–273 (1975)

    Google Scholar 

  • Herz, H., Nusselt, L.: Ein einfaches GerÄt zur Tremorregistrierung. Biomed. Tech. 18, 240–241 (1973)

    Google Scholar 

  • Klaus, D., Finke, J., Fahlbusch, W., Bachhausen, D.: Reflexzeitmessung sowie Tremor-Registrierung mittels Infraton-Pulsabnehmer. Med. Welt, 25, 698–701 (1974)

    Google Scholar 

  • Marsden, C. D., Foley, T. H., Owen, D. A. L., McAllister, R. G.: Peripheral Β-adrenergic receptors concerned with tremor. Clin. Sci. 33, 53–65 (1967)

    Google Scholar 

  • Potvin, A. R., Tourtelotte, W. W., Snyder, D. N., Henderson, W. G., Albers, J. W.: Validity of quantitative test measuring tremor. Amer. J. Phys. Med. 54, 243–252 (1975)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Behling, K., Bleichert, A. & Scarperi, M. A method for the measurement of tremor, and a comparison of the effects of tocolytic Β-mimetics. Europ. J. Appl. Physiol. 39, 203–207 (1978). https://doi.org/10.1007/BF00421347

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00421347

Key words

Navigation