Summary
The findings on computed tomography (CT) and neuropathological examinations were correlated in 87 autopsied cases of cerebrovascular disease with regard to the size and location of lesions, experience of reviewers, and improvement in CT quality. Small infarctions less than 5 mm were very difficult to detect accurately on CT. This was largely because of the limitations in the efficiency of the CT scanner. Accurate diagnosis of medium sized infarctions was also often difficult. This was mainly due to the anatomical location of lesions, the confluence of deep and widened sulci, periventricular white matter, and structures in the posterior fossa. Large infections could be visualized easily on CT, except in their early periods or in cases with hemorrhagic infarctions. The improved accuracy of CT diagnosis for small and medium sized infarctions could not be attained by the experience of reviewers, but was only possible by instrumental improvement of CT quality.
Zusammenfassung
In einem Autopsiematerial von 87 Fällen werden die Ergebnisse der Computertomographie einerseits und der neuropathologischen Untersuchung andererseits bei vasculären cerebralen Erkrankungen verglichen. Im besonderen werden die Größe und Lokalisation der Schädigungen, die Erfahrung der Beurteiler und technische Verbesserungen des CT berücksichtigt. Kleine Infarkte von weniger als 5 mm Durchmesser waren außerordentlich schwer im CT nachzuweisen. Dies war vorwiegend auf die technischen Grenzen des CT zurückzuführen. Auch die korrekte Diagnose von mittelgroßen Infarzierungen war oft schwierig. Dies war vorwiegend auf die anatomische Lokalisation der Läsionen zurückzuführen, nämlich die Nachbarschaft zu erweiterten und tiefen Sulci, die Lage in der periventriculären weißen Substanz sowie innerhalb von Strukturen der hinteren Schädelgrube. Große Infarkte konnten im CT leicht nachgewiesen werden mit Ausnahme der frühen Phase oder bei hämorrhagischer Infarzierung. Eine verbesserte Treffsicherheit der CT Diagnostik für kleine und mittlere Infarzierungen konnte nicht durch eine zunehmende Erfahrung der Beurteiler, sondern lediglich durch eine technische Verbesserung der Computertomographie erreicht werden.
Similar content being viewed by others
References
Alcala H, Gado M, Torack RM (1978) The effect of size, histologic elements, and water content on the identification of cerebral infarcts. A computerized cranial tomographic study. Arch Neurol 35:1–7
Brahme FJ (1978) CT diagnosis of cerebrovascular disorders—a review. Comp Tomog 2:173–181
Glydensted C, Lester J, Thomsen J (1976) Computer tomography in the diagnosis of cerebellopontine angle tumours. Neuroradiology 11:191–197
Lane B, Carroll BA, Pedley TA (1978) Computerized cranial tomography in cerebral diseases of white matter. Neurology 28:534–544
Messina AV, Chernick NL (1975) Computed tomography: the “resolving” intracerebral hemorrhage. Radiology 118:609–613
Mori H, Lu CH, Chiu LC, Cancilla PA, Christie JH (1977) Reliability of computed tomography: Correlation with neuropathological findings. Am J Roentgenol 128:795–798
New PFJ, Scott WR, Schnur JA, Davis KR, Taveras JM (1974) Computed axial tomography with the EMI scanner. Radiology 110:109–123
New PFJ, Scott WR (1975) Patient positioning. In: New PFJ, Scott WR (eds) Computed tomography of the brain and orbit (EMI scanner). Williams & Wilkins, Baltimore, pp 23–24
Paxton R, Ambrose J (1974) The EMI scanner. A brief review of the first 650 patients. Br J Radiol 47:530–565
Zatz LM (1978) Image quality in cranial computed tomography. J Comp Ass Tomo 2:336–346