Die Impedanzmessung zur Beurteilung von Ischämieschäden der humanen Leber in der Vorbereitung zur Transplantation

  • Originalarbeiten/Original Investigations
  • Published:
Langenbecks Archiv für Chirurgie Aims and scope Submit manuscript

Abstract

In 22 human donor livers the measurement of the non-invasive bioelectrical impedance was performed prospectively to evaluate the degree of tissue damage sustained during cold ischemia. The results of the measurement were correlated with liver function, the method of organ preservation and the period of ischemia. The impedance was measured in vivo as 620 ohm (at 192 Hz), the phase angle as −7.4° (at 5 kHz). The results were compared with the data obtained from 72 patients who underwent elective laparotomies. The 22 donor livers were studied further during ischemia. The method was found to be a reliable way of detecting severe damage to the hepatocytes during the cold ischemia.

Zusammenfassung

Bei 22 Lebern, die zur Transplantation beim Menschen perfundiert und entnommen wurden, wurde das Verfahren der nichtinvasiven Messung der bioelektrischen Impedanz prospektiv angewendet. Im Verlauf der Messung sollten Rückschlüsse auf einen möglichen Ischamieschaden der Organe gezogen wurden. Die Meßwerte wurden zur Funktion der Lebern, den Ischämiezeiten und den Konservierungsverfahren in Beziehung gesetzt. Für die Impedanz ergaben sich in vivo bei 192 Hz im Mittel 620 Ohm, für den Phasenwinkel bei 5 kHz −7,4°. Diese Werte entsprachen denen eines Kollektivs von 72 lebergesunden Patienten (mittels Multivarianz aus einem untersuchten Kollektiv von 132 Patienten ermittelt), die intraoperativ durchgeführt wurden. Die 22 Transplantatlebern wurden in den Ischämiephasen mit jeweils mindestens 5 Meßpunkten weiterverfolgt. Das Verfahren wurde als geeignet befunden, schwere hepatozelluläre Schäden im Verlauf der Kaltischämie zu erfassen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Ellenby MI, Small KW, Wells RM, Hoyt DJ, Lowe JE (1987) On-line detection of reversible myocardial ischernic injury by measurement electrical impedance. Ann Thorac Surg 44:587–597

    Google Scholar 

  2. Fenzlein PG, Abendroth D, Schilling M, Schaidt M, Land W (1991) Biochemical multisensor element for estimation of organ viability Transplant Proc 23, 1302–1303

    Google Scholar 

  3. Fourcade C, Barbier M, Perrin P, Chignier de Alcantara E, Descotes J (1973) Impedance tissulaire. Nouv Presse Med 13:837–838

    Google Scholar 

  4. Gebhard MM, Gersing E, Brockhoff CJ, Schnabel PA, Bretschneider HJ (1987) Impedance spectroscopy: a method of surveillance of ischemia tolerance of the heart. Thorac Cardiovasc Surg 35:26–30

    Google Scholar 

  5. Gersing E (1991) Messung der elektrischen Impedanz von Organen-Apparative Ausrüstung für Forschung und klinische Anwendung. Biomed Tech 36:6–11

    Google Scholar 

  6. Gersing E, Bach F, Brockhoff C, Gebhard MM, Kehrere G, Meißner A, Brettschneider HJ (1991) Messung der elektrischen Impedanz von Organen — Methodische Grundlagen. Biomed Tech 36:70–77

    Google Scholar 

  7. MacDonald JR, Potter LD jr (1987) A flexible procedure for analyzing impedance spectroscopy results: description and illustrations. Solid State Ionics 23:61–79

    Google Scholar 

  8. Rigler B, Lanner G, Hermann W, Stenzel W (1974) Vergleichende Studien der Impedanzmessung an der transplantierten Leber. Langenbecks Arch Chir 336:173–179

    Google Scholar 

  9. Schön G, Schmidt R (1985) Impedanzspectroscopy. Solid State Ionics 17:231–240

    Google Scholar 

  10. Schwan HP (1963) Determination of biological impedance. In: Nastruk WL (ed) Electrophysiological methods; Kart, B Vol VI. Academic Press, New York London, pp 323–407

    Google Scholar 

  11. Seemann B, Templin R, Bast R, Hudemann B, John R, Schmidt U, Erdmann T (1983) Untersuchungen zur Wertigkeit der Dielektrizitätskonstanten als Vitalitätstest Z Urol Nephrol 9:605–608

    Google Scholar 

  12. Stremmel W, Wojdat R, Groteguth M, Zoedler T, Ebener C, Niederau C, Becker H, Strohmeyer G (1992) Leberfunktionstest im klinischen Vergleich. Z Gastroenterol 30:784–790

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Erhard, J., Lange, R., Gersing, E. et al. Die Impedanzmessung zur Beurteilung von Ischämieschäden der humanen Leber in der Vorbereitung zur Transplantation. Langenbecks Arch Chir 378, 233–238 (1993). https://doi.org/10.1007/BF00184365

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00184365

Key words

Navigation