Implementation of a Hybrid Renewable Energy Plant with Remote Monitoring Feature

  • Conference paper
  • First Online:
Artificial Intelligence and Evolutionary Computations in Engineering Systems

Part of the book series: Advances in Intelligent Systems and Computing ((AISC,volume 394))

  • 2098 Accesses

Abstract

This study is intended to present the implementation of a hybrid renewable energy plant where solar and wind energy conversion systems are installed together. The hybrid plant consists of a wind turbine with permanent magnet synchronous generator (PMSG) at 2 kWp rated power and solar panel array at 0.64 kWp rated power. The generated energy is coupled on the dc bus bar and is supplied to energy storage subsystem in order to ensure the sustainability of energy. The stored energy is used to meet energy requirement of a microprocessor laboratory where the left energy is supplied to the grid in spare times. The plant is developed with communication features that enable to observe the plant remotely. This is performed with the designed data acquisition card that consists of current and voltage sensors, and microprocessor communicating with computer over universal serial bus (USB) port. The user interface software that generates log files and graphs is built by using Visual C#.Net platform. The implemented system is assumed as an essential training and education plant in terms of distributed generation, renewable energy sources, smart grid, and remote monitoring.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Kirubakaran K, Jain S, Nema RK. DSP-controlled power electronic interface for fuel-cell-based distributed generation. IEEE Trans Power Electron. 2011;26:3853–64.

    Article  Google Scholar 

  2. Nissen MB. High performance development as distributed generation. IEEE Potentials. 2009;28:25–31.

    Article  Google Scholar 

  3. Senjyu T, Miyazato Y, Yona A, Urasaki N, Funabashi T. Optimal distribution voltage control and coordination with distributed generation. IEEE Trans Power Delivery. 2008;23:1236–42.

    Article  Google Scholar 

  4. Cui J, Li K, Sun Y, Zou Z, Ma Y. Distributed energy storage system in wind power generation. In: 2011 4th International conference on electric utility deregulation and restructuring and power technologies (DRPT); 2011. p. 1535–1540.

    Google Scholar 

  5. Çolak I, Kabalcı E. Practical implementation of a digital signal processor controlled multilevel inverter with low total harmonic distortion for motor drive applications. J Power Sources. 2011;196:7585–93.

    Article  Google Scholar 

  6. Semikron Inc., Current Transducer LA 55-P. http://www.semikron.com/products/data/cur/assets/LA_55_P_90_13_25_000_0_13950120.pdf. Accessed 24 Dec 2012.

  7. Kabalcı E, Kabalcı Y. Multi-channel power line communication system design for hybrid renewables. In: 4th International conference on power engineering, energy and electrical drives; 2013. p. 563–8.

    Google Scholar 

  8. Kabalcı E, Gorgun A, Kabalcı Y. Design and implementation of a renewable energy monitoring system. In: 4th International conference on power engineering, energy and electrical drives; 2013. p. 1071–5.

    Google Scholar 

  9. Microchip Technology Inc., PIC18F2455/2550/4455/4550 Data Sheet, 2006. http://ww1.microchip.com/downloads/en/devicedoc/39632c.pdf. Accessed 24 Dec 2012.

  10. Colak I, Kabalcı E. Developing a novel sinusoidal pulse width modulation (SPWM) technique to eliminate side band harmonics. Int J Electr Power Energy Syst. 2014;44:861–71.

    Article  Google Scholar 

  11. Colak I, Kabalcı E. Implementation of energy efficient inverter for renewable energy sources. Electric Power Comp Syst. 2014;41:31–46.

    Article  Google Scholar 

Download references

Acknowledgments

Installation of hybrid renewable plant is funded by Scientific Research Division (NEUBAP) of Nevsehir University with ref. No. 2012/13. Ersan Kabalci acknowledges to NEUBAP for the support in this study.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ramazan Bayindir .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer India

About this paper

Cite this paper

Kabalci, E., Bayindir, R. (2016). Implementation of a Hybrid Renewable Energy Plant with Remote Monitoring Feature. In: Dash, S., Bhaskar, M., Panigrahi, B., Das, S. (eds) Artificial Intelligence and Evolutionary Computations in Engineering Systems. Advances in Intelligent Systems and Computing, vol 394. Springer, New Delhi. https://doi.org/10.1007/978-81-322-2656-7_102

Download citation

  • DOI: https://doi.org/10.1007/978-81-322-2656-7_102

  • Published:

  • Publisher Name: Springer, New Delhi

  • Print ISBN: 978-81-322-2654-3

  • Online ISBN: 978-81-322-2656-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics