C-arm Tracking by Intensity-Based Registration of a Fiducial in Prostate Brachytherapy

  • Conference paper

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 6135))

Abstract

Motivation: In prostate brachytherapy, intra-operative dosimetry optimization can be achieved through reconstruction of the implanted seeds from multiple C-arm fluoroscopy images. This process requires tracking of the C-arm poses. Methodology: We compute the pose of the C-arm relative to a stationary radiographic fiducial of known geometry. The fiducial was precisely fabricated. We register the 2D fluoroscopy image of the fiducial to a projected digitally reconstructed radiograph of the fiducial. The novelty of this approach is using image intensity alone without prior segmentation of the fluoroscopy image. Experiments and Results: Ground truth pose was established for each C-arm image using a published and clinically tested segmentation-based method. Using 111 clinical C-arm images and ±10° and ±10 mm random perturbation around the ground-truth pose, the average rotation and translation errors were 0.62° (std=0.31°) and 0.73 mm (std= 0.55mm), respectively. Conclusion: Fully automated segmentation-free C-arm pose estimation was found to be clinically adequate on human patient data.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Jemal, A., Siegel, R., Ward, E., et al.: Cancer Statistics. CA Cancer J. Clin. 59(4), 225–249 (2009)

    Article  Google Scholar 

  2. Zelefsky, M.J., Kuban, D.A., Levy, L.B., et al.: Multi-institutional analysis of long-term outcome for stages T1-T2 prostate cancer treated with permanent seed implantation. Int. J. Radiat. Oncol. Biol. Phys. 67(2), 327–333 (2007)

    Google Scholar 

  3. Nag, S., Ciezki, J.P., Cormack, R., et al.: Intraoperative planning and evaluation of permanent prostate brachytherapy: report of the American Brachytherapy Society. Int. J. Radiat. Oncol. Biol. Phys. 51(5), 1422–1430 (2001)

    Google Scholar 

  4. Orio, P.F., Tutar, I.B., Narayanan, S., et al.: Intraoperative ultrasound-fluoroscopy fusion can enhance prostate brachytherapy quality. Int. J. Radiat. Oncol. Biol. Phys. 69(1), 302–327 (2007)

    Google Scholar 

  5. Westendorp, H., Hoekstra, C.J., van’t Riet, A., et al.: Intraoperative adaptive brachytherapy of iodine-125 prostate implants guided by C-arm cone-beam computed tomography-based dosimetry. Brachytherapy 6(4), 231–237 (2007)

    Article  Google Scholar 

  6. Su, Y., Davis, B.J., Furutani, K.M., et al.: Seed localization and TRUS- fluoroscopy fusion for intraoperative prostate brachytherapy dosimetry. Computer Aided Surgery 12(1), 25–34 (2007)

    Article  Google Scholar 

  7. Jain, A.K., Deguet, A., Iordachita, I., et al.: Intra-operative Guidance in Prostate Brachytherapy Using an Average Carm. In: Ayache, N., Ourselin, S., Maeder, A. (eds.) MICCAI 2007, Part II. LNCS, vol. 4792, pp. 9–16. Springer, Heidelberg (2007)

    Chapter  Google Scholar 

  8. Yao, J., Taylor, R.H., Goldberg, R.P., et al.: A C-arm fluoroscopy-guided progressive cut refinement strategy using a surgical robot. Comput. Aided Surg. 5, 373–390 (2000)

    Article  Google Scholar 

  9. Zhang, M., Zaider, M., Worman, M., Cohen, G.: On the question of 3d seed reconstruction in prostate brachytherapy: the determination of x-ray source and film locations. Phys. Med. Biol. 49, 335–345 (2004)

    Article  Google Scholar 

  10. Yaniv, Z., Joskowicz, L.: Precise robot-assisted guide positioning for distal locking of intramedullary nails. IEEE Trans. Med. Imaging 24, 624–635 (2005)

    Article  Google Scholar 

  11. Tang, T.S.Y., MacIntyre, N.J., Gill, H.S., et al.: Accurate assessment of patellar tracking using fiducial and intensity-based fluoroscopic techniques. Med. Image Anal. 8, 343–351 (2004)

    Article  Google Scholar 

  12. Jain, A.K., Mustufa, T., Zhou, Y., et al.: FTRAC–a robust fluoroscope tracking fiducial. Medical physics 32(10), 3185–3198 (2005)

    Article  Google Scholar 

  13. Jain, A., Fichtinger, G.: C-arm Tracking and Reconstruction without an External Tracker. In: Larsen, R., Nielsen, M., Sporring, J. (eds.) MICCAI 2006, Part I. LNCS, vol. 4190, pp. 494–502. Springer, Heidelberg (2006)

    Chapter  Google Scholar 

  14. Jain, A., Kon, R., Zhou, Y., et al.: C-arm calibration - is it really necessary? In: Duncan, J.S., Gerig, G. (eds.) MICCAI 2005. LNCS, vol. 3749, pp. 639–646. Springer, Heidelberg (2005)

    Chapter  Google Scholar 

  15. Gueziec, A., Wu, K., Kalvin, A., et al.: Providing visual information to validate 2-d to 3-d registration. Medical Image Analysis 4, 357–374 (2000)

    Article  Google Scholar 

  16. Zuffi, S., Leardini, A., Catani, F., et al.: A model-based method for the reconstruction of total knee replacement kinematics. IEEE Trans. Med. Imag. 18(10), 981–991 (1999)

    Article  Google Scholar 

  17. Yamazaki, T., Watanabe, T., Nakajima, Y., et al.: Improvement of depth position in 2d/3d registration of knee implants using single-plane fluoroscopy. IEEE Trans. on Medical Imaging 23(5), 602–612 (2004)

    Article  Google Scholar 

  18. Nister, D.: An efficient solution to the five-point relative pose problem. IEEE Trans. on Pattern Analysis and Machine Intelligence 26(6), 756–770 (2004)

    Article  Google Scholar 

  19. Fischler, M., Bolles, R.: Random sample consensus: A paradigm for model fitting with applications to image analysis and automated cartography. Comm. Assoc. Comp. Mach. 24(6), 381–395 (1981)

    MathSciNet  Google Scholar 

  20. Livyatan, H., Yaniv, Z., Joskowicz, L.: Gradient-based 2-D/3-D rigid registration of fluoroscopic X-ray to CT. IEEE Trans. Med. Imaging 22, 1395–1406 (2003)

    Article  Google Scholar 

  21. Mahfouz, M., Hoff, W., Komistek, R., Dennis, D.: A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images. IEEE Transactions on Medical Imaging 22, 1561–1574 (2003)

    Article  Google Scholar 

  22. Lau, K., Chung, A.: A global optimization strategy for 3d-2d registration of vascular images. In: Proceedings of 17th British Machine Vision Conference, pp. 489–498 (2006)

    Google Scholar 

  23. Kovesi, P.: Functions for Computer Vision and Image Processing (2009), http://www.csse.uwa.edu.au/~pk/research/matlabfns/

  24. Gilboa, G., Sochen, N., Zeevi, Y.: Regularized shock filters and complex diffusion. In: Heyden, A., Sparr, G., Nielsen, M., Johansen, P. (eds.) ECCV 2002. LNCS, vol. 2350, pp. 399–413. Springer, Heidelberg (2002)

    Chapter  Google Scholar 

  25. Hansen, N.: The CMA Evolution Strategy: A Comparing Review. Studies in fuzziness and soft computing 192, 75–102 (2006)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Fallavollita, P., Burdette, C., Song, D.Y., Abolmaesumi, P., Fichtinger, G. (2010). C-arm Tracking by Intensity-Based Registration of a Fiducial in Prostate Brachytherapy. In: Navab, N., Jannin, P. (eds) Information Processing in Computer-Assisted Interventions. IPCAI 2010. Lecture Notes in Computer Science, vol 6135. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-13711-2_5

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-13711-2_5

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-13710-5

  • Online ISBN: 978-3-642-13711-2

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics