Skip to main content

WADEDA: A Wearable Affective Device with On-Chip Signal Processing Capabilities for Measuring ElectroDermal Activity

  • Conference paper
XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010

Part of the book series: IFMBE Proceedings ((IFMBE,volume 29))

Abstract

In this paper a miniaturized and wearable skin conductance sensor equipped with a micro-processor is proposed. The device facilitates the acquisition of long-term monitoring of the electrodermal activity under real-world situations. Its generic and flexible design permits the data storage during daily activities, while the prototype equipped with on-chip firmware, performs real-time signal filtering and feature extraction. The system’s architecture based on the recent hardware advances, aims to enhance the robustness of previous skin conductance sensors. Emerging applications under non-laboratory experiments are introduced in order to highlight the applicability of the proposed device. The results obtained from preliminary experiments are described.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 349.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 449.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 International Federation for Medical and Biological Engineering

About this paper

Cite this paper

Konstantinidis, E.I., Frantzidis, C.A., Papadelis, C., Pappas, C., Bamidis, P.D. (2010). WADEDA: A Wearable Affective Device with On-Chip Signal Processing Capabilities for Measuring ElectroDermal Activity. In: Bamidis, P.D., Pallikarakis, N. (eds) XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010. IFMBE Proceedings, vol 29. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-13039-7_69

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-13039-7_69

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-13038-0

  • Online ISBN: 978-3-642-13039-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics