Skip to main content

Can the EEG Indicate the FiO2 Flow of a Mechanical Ventilator in ICU Patients with Respiratory Failure?

  • Conference paper
XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010

Part of the book series: IFMBE Proceedings ((IFMBE,volume 29))

  • 150 Accesses

Abstract

The aim of this paper is to show that the brain activity of patients with acute respiratory failure hospitalized in Intensive Care Units (ICUs) can provide useful medical information, which is directly related to neurological rehabilitation. It also aims to show that the entropy and kurtosis, widely used indices of the electroencephalographic (EEG) signals, are able to identify EEG changes associated with cerebral hypoxia. EEG signals were recorded from eight adult patients with acute respiratory failure admitted to the ICU. The measurements were recorded in five stages, with FiO2 at 40%, 100%, 60%, 20% and 0% (T-piece) respectively. Total time of recordings was 50min (10 min. for each stage). The EEG signals were filtered and further cleaned from ocular and muscular artifacts as well as from the artifacts introduced by other external devices, electrodes movements and electrode’s bad tangencies. Afterwards the 10-min EEG signals of each stage were segmented in ten epochs with one minute fixed length. Then Kurtosis and Shannon’s Entropy were calculated in each segment. One-Way ANOVA verified the assumption that there are statistically significant differences between the various stages of our protocol, while the Scheffe Post-Hoc tests revealed the homogeneous subsets compiled by the aforementioned stage. The results suggest that the EEG is directly connected with the mechanical ventilator’s changes, so in the future, clinicians could probably use the EEG as particularly useful and time-critical information, especially during the weaning procedure from the mechanical ventilator.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 349.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 449.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 International Federation for Medical and Biological Engineering

About this paper

Cite this paper

Peranonti, E.G., Klados, M.A., Papadelis, C.L., Kontotasiou, D.G., Kourtidou-Papadeli, C., Bamidis, P.D. (2010). Can the EEG Indicate the FiO2 Flow of a Mechanical Ventilator in ICU Patients with Respiratory Failure?. In: Bamidis, P.D., Pallikarakis, N. (eds) XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010. IFMBE Proceedings, vol 29. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-13039-7_209

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-13039-7_209

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-13038-0

  • Online ISBN: 978-3-642-13039-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics