Simulation and Phantom Studies of Contrast-Enhanced Dual Energy Mammography (CEDEM)

  • Conference paper

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 5116))

Abstract

Contrast-enhanced dual energy mammography (CEDEM) has been shown effective in enhancing the visibility of breast cancer in diagnostic mammographic images. The simulation and phantom studies of CEDEM were implemented to enhance acquisition techniques of a dedicated cone-beam breast CT scanner fabricated in our laboratory. CEDEM images were computer-simulated numerically, and the results were compared and validated with physical experiments using a custom-made breast-equivalent phantom with pseudo anatomical structures. The technique factors to be optimized included low- and high-energy x-ray spectra (kVp), spectra filters and mAs (x-ray tube current × scan time in second). Signal-difference-to-noise ratio (SDNR) of the log-weighted subtracted image was computed to optimize subtraction parameters using several combinations of breast compositions and thicknesses. Both simulation and phantom studies suggest that 40 kVp (filtered with 1.5 mm Al) and 50 kVp (filtered with 1.5 mm Al and 0.3 mm Cu) were the optimal spectra with the highest SDNR on the dual energy subtracted image of a 6-cm, 50% glandular breast. Breast composition and thickness were found to have little influence on the optimized technique factors. We conclude that the simulation and phantom studies demonstrated the effectiveness of CEDEM using the prototype breast CT scanner in producing high-quality, lesion-enhanced images.

This is a preview of subscription content, log in via an institution.

We’re sorry, something doesn't seem to be working properly.

Please try refreshing the page. If that doesn't work, please contact support so we can address the problem.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Lewin, J.M., Isaacs, P.K., Vance, V., Larke, F.J.: Dual-energy contrast-enhanced digital subtraction mammography: feasibility. Radiology 229(1), 261 (2003)

    Article  Google Scholar 

  2. Kriege, M., Brekelmans, C.T., Boetes, C., Besnard, P.E., Zonderland, H.M., Obdeijn, I.M., Manoliu, R.A., Kok, T., Peterse, H., Tilanus-Linthorst, M.M., Muller, S.H., Meijer, S., Oosterwijk, J.C., Beex, L.V., Tollenaar, R.A., de Koning, H.J., Rutgers, E.J., Klijn, J.G.: Efficacy of MRI and mammography for breast-cancer screening in women with a familial or genetic predisposition. N. Engl. J. Med. 351(5), 427 (2004)

    Article  Google Scholar 

  3. Boone, J.M., Seibert, J.A.: An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV. Med. Phys. 24(11), 1661 (1997)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Elizabeth A. Krupinski

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Huang, SY., Boone, J.M., Zheng, D., Yang, K., Packard, N.J., Burkett, G. (2008). Simulation and Phantom Studies of Contrast-Enhanced Dual Energy Mammography (CEDEM). In: Krupinski, E.A. (eds) Digital Mammography. IWDM 2008. Lecture Notes in Computer Science, vol 5116. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-70538-3_18

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-70538-3_18

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-70537-6

  • Online ISBN: 978-3-540-70538-3

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics