Abstract
Respiratory motion is a limiting factor during cancer therapy. Although image tracking can facilitate compensation for this motion, system latencies will still reduce the accuracy of tracking-based treatments. We propose a novel approach for temporal prediction of the motion of anatomical targets in the liver, observed from ultrasound sequences. The method is based on an ensemble of six prediction models, including neural networks, which are trained on motion traces and images. Using leave-one-subject-out validation on 24 liver ultrasound 2D sequences from the Challenge on Liver Ultrasound Tracking, the best performance was achieved by the linear regression-based ensemble of all methods with an accuracy of 1.49 (2.39) mm for a latency of 300 (600) ms.
Keywords
V. De Luca—We acknowledge funding from EU’s 7th Framework Program under grant no. 611889 (TRANS-FUSIMO).
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
Cleveland, W.S., Devlin, S.J.: Locally weighted regression: an approach to regression analysis by local fitting. J. Am. Stat. Assoc. 83(403), 596 (1988)
De Luca, V., Benz, T., Kondo, S., König, L., Lübke, D., Rothlübbers, S., Somphone, O., Allaire, S., Bell, M.L., Chung, D., et al.: The 2014 liver ultrasound tracking benchmark. PMB 60(14), 5571 (2015)
De Luca, V., Tschannen, M., Székely, G., Tanner, C.: A learning-based approach for fast and robust vessel tracking in long ultrasound sequences. In: Mori, K., Sakuma, I., Sato, Y., Barillot, C., Navab, N. (eds.) MICCAI 2013, Part I. LNCS, vol. 8149, pp. 518–525. Springer, Heidelberg (2013)
He, K., Zhang, X., Ren, S., Sun, J.: Delving deep into rectifiers: surpassing human-level performance on ImageNet classification. In: IEEE ICCV, p. 1026 (2015)
Isakkson, M., Jaiden, J., Murphy, M.: On using an adaptive neural network to predict lung tumor motion during respiration for radiotherapy applications. Med. Phys. 32(12), 3801 (2005)
Kakar, M., Nyström, H., Aarup, L.R., Nøttrup, T.J., Olsen, D.R.: Respiratory motion prediction by using the adaptive neuro fuzzy inference system (ANFIS). PMB 50(19), 4721 (2005)
Keall, P.J., Mageras, G.S., Balter, J.M., Emery, R.S., Forster, K.M., Jiang, S.B., Kapatoes, J.M., Low, D.A., Murphy, M.J., Murray, B.R., et al.: The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med. Phys. 33(10), 3874 (2006)
Krauss, A., Nill, S., Oelfke, U.: The comparative performance of four respiratory motion predictors for real-time tumour tracking. PMB 56(16), 5303 (2011)
Lee, S.J., Motai, Y.: Review: prediction of respiratory motion. Prediction and Classification of Respiratory Motion, pp. 7–37. Springer, Heidelberg (2014)
Makhinya, M., Goksel, O.: Motion tracking in 2D ultrasound using vessel models and robust optic-flow. In: Proceedings of MICCAI CLUST, p. 20 (2015)
O’Shea, T., Bamber, J., Fontanarosa, D., van der Meer, S., Verhaegen, F., Harris, E.: Review of ultrasound image guidance in external beam radiotherapy part II: intra-fraction motion management and novel applications. PMB 61(8), R90 (2016)
Poulsen, P.R., Cho, B., Sawant, A., Ruan, D., Keall, P.J.: Detailed analysis of latencies in image-based dynamic MLC tracking. Med. Phys. 37(9), 4998 (2010)
Putra, D., Haas, O.C., Mills, J.A., Burnham, K.J.: A multiple model approach to respiratory motion prediction for real-time IGRT. PMB 53, 1651 (2008)
Ruan, D.: Kernel density estimation-based real-time prediction for respiratory motion. PMB 55(5), 1311 (2010)
Sharp, G.C., Jiang, S.B., Shimizu, S., Shirato, H.: Prediction of respiratory tumour motion for real-time image-guided radiotherapy. PMB 49(3), 425 (2004)
Tanner, C., Eppenhof, K., Gelderblom, J., Szekely, G.: Decision fusion for temporal prediction of respiratory liver motion. In: IEEE ISBI, p. 698. IEEE (2014)
Teo, P., Bruce, N., Pistorius, S.: Application and parametric studies of a sliding window neural network for respiratory motion predictions of lung cancer patients. In: Jaffray, D.A. (ed.) World Congress on Medical Physics and Biomedical Engineering. IFMBE Proceedings, vol. 51, pp. 595–598. Springer, Switzerland (2015)
Tieleman, T., Hinton, G.: Lecture 6.5-rmsprop: divide the gradient by a running average of its recent magnitude. COURSERA: Neural Netw. Mach. Learn. 4, 2 (2012)
Vedam, S., Keall, P., Docef, A., Todor, D., Kini, V., Mohan, R.: Predicting respiratory motion for four-dimensional radiotherapy. Med. Phys. 31(8), 2274 (2004)
Verma, P.S., Wu, H., Langer, M.P., Das, I.J., Sandison, G.: Survey: real-time tumor motion prediction for image-guided radiation treatment. Comput. Sci. Eng. 13(5), 24 (2011)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer International Publishing Switzerland
About this paper
Cite this paper
Chen, X., Tanner, C., Göksel, O., Székely, G., De Luca, V. (2016). Temporal Prediction of Respiratory Motion Using a Trained Ensemble of Forecasting Methods. In: Zheng, G., Liao, H., Jannin, P., Cattin, P., Lee, SL. (eds) Medical Imaging and Augmented Reality. MIAR 2016. Lecture Notes in Computer Science(), vol 9805. Springer, Cham. https://doi.org/10.1007/978-3-319-43775-0_35
Download citation
DOI: https://doi.org/10.1007/978-3-319-43775-0_35
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-43774-3
Online ISBN: 978-3-319-43775-0
eBook Packages: Computer ScienceComputer Science (R0)