Abstract
Although various modalities are used in prostate cancer imaging, transrectal ultrasound (TRUS) guided biopsy remains the gold standard for diagnosis. However, TRUS suffers from low sensitivity, leading to an elevated rate of false negative results. Magnetic Resonance Imaging (MRI) on the other hand provides currently the most accurate image-based evaluation of the prostate. Thus, TRUS/MRI fusion image-guided biopsy has evolved to be the method of choice to circumvent the limitations of TRUS-only biopsy. Most commercial frameworks that offer such a solution rely on rigid TRUS/MRI fusion and rarely use additional information from other modalities such as Positron Emission Tomography (PET). Other frameworks require long interaction times and are complex to integrate with the clinical workflow. Available solutions are not fully able to meet the clinical requirements of speed and high precision at low cost simultaneously. We introduce an open source fusion biopsy framework that is low cost, simple to use and has minimal overhead in clinical workflow. Hence, it is ideal as a research platform for the implementation and rapid bench to bedside translation of new image registration and visualization approaches. We present the current status of the framework that uses pre-interventional PET and MRI rigidly registered with 3D TRUS for prostate biopsy guidance and discuss results from first clinical cases.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Worldwide cancer key facts 2014, cancer research UK. http://publications.cancerresearchuk.org/downloads/Product/CS_KF_WORLDWIDE.pdf
Schulte zu Berge, C., Grunau, A., Mahmud, H., Navab, N.: CAMPVis - a game engine-inspired research framework for medical imaging and visualization. Technical report, Technische Universität München (2014). http://campar.in.tum.de/Main/CAMPVis
Delongchamps, N.B., Peyromaure, M., Schull, A., Beuvon, F., Bouazza, N., Flam, T., Zerbib, M., Muradyan, N., Legman, P., Cornud, F.: Prebiopsy magnetic resonance imaging and prostate cancer detection: comparison of random and targeted biopsies. J. Urol. 189(2), 493–499 (2013)
Eiber, M., Maurer, T., Beer, A., Souvatzoglou, M., Holzapfel, K., Ruffani, A., Wester, H., Schwaiger, M.: Detection rate for a novel 68GA-PSMA PET-ligand in patients with biochemical recurrence of prostate cancer using PET/CT and PET/MR imaging. In: Society of Nuclear Medicine Annual Meeting Abstracts, vol. 55, p. 13. Soc. Nuclear Med. (2014)
Lasso, A., Heffter, T., Rankin, A., Pinter, C., Ungi, T., Fichtinger, G.: Plus: open-source toolkit for ultrasound-guided intervention systems. IEEE Trans. Biomed. Eng. 61(10), 2527–2537 (2014)
Marks, L., Young, S., Natarajan, S.: MRI-ultrasound fusion for guidance of targeted prostate biopsy. Curr. Opin. Urol. 23(1), 43 (2013)
Mitra, J., Kato, Z., Martí, R., Oliver, A., Lladó, X., Sidibé, D., Ghose, S., Vilanova, J.C., Comet, J., Meriaudeau, F.: A spline-based non-linear diffeomorphism for multimodal prostate registration. Med. Image Anal. 16(6), 1259–1279 (2012)
Schroeder, W.J.: The visualization toolkit users guide: updated for version 4.0. Kitware (1998)
Sparks, R., Bloch, B.N., Feleppa, E., Barratt, D., Madabhushi, A.: Fully automated prostate magnetic resonance imaging and transrectal ultrasound fusion via a probabilistic registration metric. In: SPIE Medical Imaging, pp. 86710A–86710A. International Society for Optics and Photonics (2013)
Sperling, D.: MRI-ultrasound fusion imaging. In: Bard, R.L., Fütterer, J.J., Sperling, D. (eds.) Image Guided Prostate Cancer Treatments, pp. 115–123. Springer, Heidelberg (2014)
Tokuda, J., Fischer, G.S., Papademetris, X., Yaniv, Z., Ibanez, L., Cheng, P., Liu, H., Blevins, J., Arata, J., Golby, A.J., et al.: Openigtlink: an open network protocol for image-guided therapy environment. Int. J. Med. Robot. Comput. Assist. Surg. 5(4), 423–434 (2009)
Turkbey, B., Pinto, P.A., Choyke, P.L.: Imaging techniques for prostate cancer: implications for focal therapy. Nat. Rev. Urol. 6(4), 191–203 (2009)
Umeyama, S.: Least-squares estimation of transformation parameters between two point patterns. IEEE Trans. Pattern Anal. Mach. Intell. 13(4), 376–380 (1991)
Yoo, T.S., Ackerman, M.J., Lorensen, W.E., Schroeder, W., Chalana, V., Aylward, S., Metaxas, D., Whitaker, R.: Engineering and algorithm design for an image processing API: a technical report on ITK-the insight toolkit. Studies in Health Technology and Informatics, pp. 586–592 (2002)
Acknowledgments
This work is partially supported by the EU 7th Framework Program projects Marie Curie Early Initial Training Network Fellowship (PITN-GA-2011-289355-PicoSEC-MCNet), EndoTOFPET-US (GA-FP7/2007-2013-256984), ACTIVE (FP7/ICT-2009-6-270460), and SoftwareCampus program of the German Federal Ministry of Education and Research (BMBF, Förde- rkennzeichen 01IS12057).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer International Publishing Switzerland
About this paper
Cite this paper
Shah, A. et al. (2014). An Open Source Multimodal Image-Guided Prostate Biopsy Framework. In: Linguraru, M., et al. Clinical Image-Based Procedures. Translational Research in Medical Imaging. CLIP 2014. Lecture Notes in Computer Science(), vol 8680. Springer, Cham. https://doi.org/10.1007/978-3-319-13909-8_1
Download citation
DOI: https://doi.org/10.1007/978-3-319-13909-8_1
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-13908-1
Online ISBN: 978-3-319-13909-8
eBook Packages: Computer ScienceComputer Science (R0)