Abstract
The accuracy of an eddy current inspection depends in large part on the performance of the eddy current probe. Consistent performance requires identification of the eddy current probe parameters which characterize performance. These parameters could then serve as a basis for probe procurement specification. Their measurement would also provide a basis for the evaluation of probes which are currently used at inspection facilities and which may have deteriorated[1].
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Lew, Stuart, “Eddy Current Probe Performance Update,” Department of the Air force NDT Newsletter, Sept. 1988, p 13.
Burkhardt, G. L., R. E. Beissner, and J. L. Fisher, “Eddy Current Probe Performance Variability”, Review of P rogress in Quantia v ttie Nondesrrucrive Evaluation, Vol. 6A, ed. Donald O. Thompson and Dale E. Chimenti, 1987, pp 727–735.
Burkhardt, Gary L., T. L. Allen and S. N. Rowland, Eddy Current Probe Performance Requirement, Report SA-ALC/MMEI/88–01.
Capobianco, T. E., S. J. Ciciora and J. C. Moulder, “Standard Flaws For Eddy Current Probe Characterization,” Review of Progress in Ouantitative Nondestructive Evaluation, Vol. 8A, ed. Donald O. Thompson and Dale E. Chimenti, 1989, pp 985–989.
Capobianco, T. E. and D. F. Vecchia, “Coil Parameter Influence on Eddy Current Probe Sensitivity,” Review of Progress in Qiisnrirarive Nondestructive Evaluation, Vol. 7A, ed. Donald O. Thompson and Dale E. Chimenti, 1988, pp 487–492.
Burkhardt, G. L., “Eddy Current Probe Performance Characterization”, Review of Progress in Quantitative Nondestructive Evaluation, Vol. 8A, ed. Donald O. Thompson and Dale E. Chimenti, 1987, pp 967–974.
Capobianco, T. E., “Mapping of Eddy Current Probe Fields,” Review of Progress in Ouantitative Nondestructive Evaluation, Vol. 5A, ed. Donald O. Thompson and Dale E. Chimenti, 1986, pp 705–711.
Capobianco, T. E., “Field Mapping and Performance Characterization of Commercial Eddy Current Probes,” Review of Progress in Quantitative Nondestructive Evaluation, Vol. 6A, ed. Donald O. Thompson and Dale E. Chimenti, 1987, pp 687–694.
Vernon, S. N., Eddy Current Tnspecrion of Graphite Epoxy, Naval Surface Weapons Center Technical Report, NSWC TR-87–148, Sept. 1987.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1990 Springer Science+Business Media New York
About this chapter
Cite this chapter
Vernon, S.N. (1990). Coupling Coefficient: A Determinant of Eddy Current Probe Performance. In: Thompson, D.O., Chimenti, D.E. (eds) Review of Progress in Quantitative Nondestructive Evaluation. Review of Progress in Quantitative Nondestructive Evaluation. Springer, Boston, MA. https://doi.org/10.1007/978-1-4684-5772-8_106
Download citation
DOI: https://doi.org/10.1007/978-1-4684-5772-8_106
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4684-5774-2
Online ISBN: 978-1-4684-5772-8
eBook Packages: Springer Book Archive