Abstract
Evacuating people with reduced mobility (PRM) from multi-storey buildings can be a difficult task. A number of commercially available devices can be used to assist in moving the PRM to the ground however, there is little consistent data quantifying the relative performance of these devices. In this paper four commonly used assist devices, the Evac+Chair, Carry-Chair, Stretcher and Drag Mattress are used in a series of 32 evacuation trials designed to assess their performance. The trials involve moving a PRM from a wheelchair to the device, moving the PRM along a long corridor to a stair and then down 11 floors to the ground. The performance of the devices is then assessed in terms of travel speed on the flat and stairs, number of handlers required to operate and ease of overtaking by other stair users.
Keywords
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Galea, E.R., Hulse, L., Day, R., Siddiqui, A., Sharp, G.: "The UK WTC 9/11 Evacuation Study: an Overview of the Methodologies Employed and some Analysis Relating to Fatigue, Stair Travel Speeds and Occupant Response Times.” Proc 4th Int Symp on Human Behaviour in Fire, 13-15 July 2009, Robinson College, Cambridge, UK, pp. 27-40 (2009)
‘Fatal fire block’s layout probed.’ http://news.bbc.co.uk/1/hi/england/london/8135535.stm. Last accessed 26 July 2009
Fire Safety Risk Assessment, Means of Escape for Disabled people. HMG, Reference number 06 FRSD 03913(a) (2007) 4. Hospital fire was a ‘wake up call.’http://news.bbc.co.uk/1/hi/programmes/file_on_4/7213205.stm. Last accessed 26 July 2009
Emergency Preparedness for Persons with Disabilities and Special Needs, Final Workshop Report, ANSI Homeland Security Standards Panel (2009)
Acknowledgments
The authors are indebted to a number of people who enabled this project to happen and who assisted in carrying out the work, in particular, Prof N Fraeyman of UZ who permitted the work to be undertaken at UZ, utilising both UZ buildings and staff, Mr Filip Buckens the coordinator of the UZ Manutentie Team and his 18 staff who donated their time to the project and did all the heavy lifting (and sitting), the 24 UZ student volunteers who ran up and down the stairs, the team of UZ administrative staff who contributed to the logistics of the operation, the 11 friends of Mr Adams who volunteered to assist with the stopwatch observations, the video camera team and finally, Ms Aoife Hunt, a PhD student from FSEG who assisted with the trials and who is currently undertaking a detailed analysis of the video footage as part of her PhD studies.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2011 Springer Science+Business Media, LLC
About this paper
Cite this paper
Adams, A., Galea, E. (2011). An Experimental Evaluation of Movement Devices Used to Assist People with Reduced Mobility in High-Rise Building Evacuations. In: Peacock, R., Kuligowski, E., Averill, J. (eds) Pedestrian and Evacuation Dynamics. Springer, Boston, MA. https://doi.org/10.1007/978-1-4419-9725-8_12
Download citation
DOI: https://doi.org/10.1007/978-1-4419-9725-8_12
Published:
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4419-9724-1
Online ISBN: 978-1-4419-9725-8
eBook Packages: EngineeringEngineering (R0)